TBS Installation Manual 

 

2D IRON & 3D AIR

 

 

TBS 2D IRON 3D AIR Mounting and Installation Guideline    

• 

   TBS-056-057    

• 

   Rev 09-2023

 

page 14 of 21

 

 

5.4

 

General Purpose Input / Output 

 

 

5.4.1

 

General Purpose Inputs 

Two general purpose inputs are available on a detachable wire terminal block. These inputs can be used 
for interconnection with a door monitoring switch, request to exit button or other equipment. 

 

GP IN pull-up resistor 

Input Configuration 

Input activated by 

without  

Standard 

0 VDC logical low  
5-30 VDC logical high 

installed 

Input with selectable pull-up resistor value* 

ground line 

 

* I = maximum current [A] for the device connected to the input  
   GP IN pull-up resistor value R = I * 105 
 
The inputs are optionally activated either by grounding the input line or by applying a voltage to the 
input  line.  For  each  input  independently,  the  desired  operating  mode  is  selected  by  inserting  or 
removing a resistor to a respective GP IN pull-up resistor socket on the mainboard. 

 

Resistor is not used - the input is activated by applying a voltage (5-30V DC). 

 

Resistor  is  installed  -  the  input  is  activated  by  grounding  the  line.  The  correct  resistor  value 
needs to be properly calculated to not damage the board. 

 
If none of the GP IN pull-up resistors are connected, GPIN works in  standard  configuration, with 0V 
logical low, and 5-30V logical high. 
 

NOTE: 

It is recommended to connect ground for reference.

 

 

5.4.2

 

General Purpose Outputs 

The  range  of  the  output  voltage  can  be  selected  between  VCC  and  5V  level  using  the  jumper 
configuration on the left side of the board. 

Label on TBS Terminal 

Name 

Voltage Level 

Ground 

 

O1 

Output 1 

0V Low  - (VCC or 5V) High 

Ground 

 

O1 

Output 2 

0V Low  - (VCC or 5V) High 

The output should always be used with the power ground for reference. 

Содержание 2D IRON

Страница 1: ...of this document is always available at https cloud1 tbs biometrics com index php s IcgqtcdZXJVBrzA Revision Author New content Oct 22 2021 AG TO First Release April 13 2022 AG TO Minor updates Aug 18...

Страница 2: ...3 Mounting Instructions 9 4 3 1 Preparation 9 4 3 2 Wall Mount Box 9 4 3 3 Heavy Duty Box IP65 10 4 3 4 Flush Mount Box IP54 11 5 Power and Signal Wiring 12 5 1 Electrical Connection and Cabling 12 5...

Страница 3: ...TBS 056 ICL WM HID PROX TBS 056 PRO WM Legic Mifare Classic or Desfire TBS 056 LEM WM Wall Mount Heavy Duty IP65 none TBS 056 STD HD HID iClass TBS 056 ICL HD HID PROX TBS 056 PRO HD Legic Mifare Cla...

Страница 4: ...of our appliances must be carried out when disconnected from the power supply in particular appliances that are normally supplied by low voltage current It is prohibited to alter the device or to remo...

Страница 5: ...nditions 1 the device may not cause harmful interference and 2 the device must accept any interference received including interference that may cause undesired operation Changes or modifications not e...

Страница 6: ...ng temperature 20 to 60 C Relative humidity 10 to 90 Outdoor device use is not compliant with UL294 In the case of 3D AIR strong ambient light and or direct light into the sensor of the terminal shoul...

Страница 7: ...ame for all three mounting variants wall mount heavy duty wall mount flush mount 4 2 1 Opening the Device IMPORTANT Always disconnect power supply before opening terminals Unlock 1 Use Allen wrench si...

Страница 8: ...Allen wrench size 3 to lock front part to back cover Screw in fully and turn back half a turn IMPORTANT To avoid destruction and electrical shorts please ensure no cable or metal parts press against t...

Страница 9: ...the installation for the passage of cables Make sure that the installation wall is completely flat to allow a nice and proper mounting TBS provides very accurately manufactured enclosures that only fi...

Страница 10: ...he heavy duty variant Four 4 5mm screws and fitting raw plugs suitable for the wall material not included One screwdriver appropriate to drive the above screws One drill with a drill bit of an appropr...

Страница 11: ...t a rectangular shape with dimensions of 204 x 127 mm height x width as in the two pictures These dimensions include 1 5 mm air spacing all around the box It is not required to cut the precise box dim...

Страница 12: ...of the wire terminal before removing the cable to unlock the latch NOTE Removing cables with force from the wire terminal may damage the wire terminal or the board Unlock the latches before removing...

Страница 13: ...wer supply to the terminal can also be provided by Ethernet using RJ45 connection Power over Ethernet IEEE802 3af compliant TBS recommends using an ethernet cable of Cat5e standard or higher The termi...

Страница 14: ...age to the input line For each input independently the desired operating mode is selected by inserting or removing a resistor to a respective GP IN pull up resistor socket on the mainboard Resistor is...

Страница 15: ...activate security access equipment For such TBS offers two dedicated controllers 5 6 Connecting TBS Controllers For various applications TBS Terminals need to be connected with external controllers e...

Страница 16: ...pen Closes when the tamper switch is activated C Common 30 VDC 1A 220 VDC 0 14 A 120 VDC 0 25 A 250 VAC 0 12 A NC Normally Closed Opens when the tamper switch is activated A recommended way of utilizi...

Страница 17: ...ring regular usage Special tests to check for correct functioning are therefore not required TBS recommends checking the integrity of the sensor surfaces and openings of the terminals at least every 6...

Страница 18: ...unication with reader failed Shutdown and re power the device 423 RFID card reading error 430 Unknown Relay GPIO error 431 Relay GPIO communication error 440 General problem with external verification...

Страница 19: ...8 HTTPS communication channel to BME server and Device Control Center DCC No Yes Enrollment API 8281 8282 8284 HTTP S communication channel between enrollment components Yes 2 No 8283 MQTT Enrollment...

Страница 20: ...T Enrollment PC WE channel 1 80 443 HTTP S communication channel to WE server and Device Control Center DCC No Yes Series12 terminal WebEdition 1 80 443 HTTP S communication channel to WE server and D...

Страница 21: ...istered TBS Partners TBS System Requirements Permanent link https cloud1 tbs biometrics com index php s q8V3hzrLyR0Mnyg Summarizes the prerequisites a site needs to offer regarding server network to h...

Отзывы: