6. Specification 

Model 

CC2.0L 

CC3.0L 

AC inputs 

Input voltage range:175~265 VAC, Input frequency:45~65Hz 

AC input Current   

32A (transfer switch) 

Inverter 

Nominal battery voltage 

12VDC 

Input voltage range 

10.5~17VDC 

Output 

Voltage: 220/230/240 VAC ± 2%, Frequency: 50/60 Hz ± 0.1% 

Harmonic distortion 

<2% 

Power factor 

1.0 

Cont. output power at 25°C 

2000W 

3000W 

Output power (30min) at 25°C 

2150W 

3200W 

Peak power 

4000W 

6000W 

Cont. output power at 40°C 

1800W 

2700W 

Maximum efficiency 

93% 

Zero load power 

12W 

16W 

Charger 

Charge voltage 'absorption' 

14.4VDC 

Charge voltage 'float' 

13.8VDC 

Battery types 

AGM / GEL / OPZV / Lead-Carbon / Li-ion / Flooded

 

Battery Charge current 

100A 

150A 

Temperature compensation

 

Yes 

General data 

AC Out Current 

32A 

Transfer time 

<4ms (<15ms when WeakGrid Mode) 

Remote on-off 

Yes 

Programmable relay 

2x 

Protection 

a) output short circuit,    b) overload,    c) battery voltage over voltage 
d) battery voltage under voltage,    e)over temperature, f) Fan block 
g) input voltage out of range,    h) input voltage ripple too high 

General purpose com. Port 

RS485 

Operating temperature range 

-

20 to +65˚C 

Storage temperature range 

-

40 to +70˚C 

Relative humidity in 
operation 

95% without condensation 

Altitude 

2000m 

Mechanical Data 

Dimension 

510*245*135mm

 

Net Weight 

17kg 

21kg 

Cooling 

Forced fan 

Protection index 

IP20 

Standards 

Satety 

EN-IEC 62477-1 

EMC 

EN61000-6-1,EN61000-6-2,EN61000-6-3,EN61000-3-11,EN61000-3-12 

 

 

Содержание Energier Mobile CC2.0L

Страница 1: ......

Страница 2: ...Energier MobileUser Manual...

Страница 3: ...Energier MobileUser Manual WARNING HIGH VOLTAGE INSIDE CAUTION THE DC FUSE MUST HAVE BEENTURNED OFF BEFORE SERVICING MADE IN CHINA...

Страница 4: ...ble for Energier Mobile Inverter Charger Combination This chapter contains important safety and operation instructions Read and keep this User Guide well for later reference The Energier Mobile Invert...

Страница 5: ...Remote control and monitor MCK 4 2 2 4 Connection compartment 5 2 2 5 Dimension 6 2 3 Function 6 2 3 1 Powerful and Reliable Inverter 6 2 3 2 Professional Battery Charger for lead acid battery 7 2 3 3...

Страница 6: ...ation otherwise the Energier Mobile Inverter Charger Combination would be overheating To avoid fire and electric shock make sure all cables selected with right gauge and being connected well Smaller d...

Страница 7: ...compressor power tool etc With the function of power assist power control it can be used to work with a limited AC source such as generator or limited grid Energier Mobile can automatically adjust its...

Страница 8: ...cture 2 2 1 Front Figure 2 1 Inverter Charger Combination structure in front view 2 2 2 Control panel Mode LED Indication ON OFF Power LED Indication Mute Unlock the fault and alarm Figure 2 2 Inverte...

Страница 9: ...ill flash when CC have warning Fault It will flash when CC have error 2 2 3 Remote control and monitor MCK Apart from above control panel the user is also allowed to monitor control and configure CC b...

Страница 10: ...A dry contact input for remote on off often IGN was connected Com MON RS485 port for external monitor such as MCK SNMP etc Com Sync Communication with TBB s M or P series lithium battery which is able...

Страница 11: ...utility grid Pure sine wave can guarantee the correct function of sensitive equipment computer laser printer TV etc Also your home appliances will work smoother cooler and more efficient such as fridg...

Страница 12: ...e charging formula must be adjusted automatically and in real time according to the actual battery temperature to ensure that battery is fully charged but not overcharged or undercharged All charging...

Страница 13: ...start automatically At this time the user needs to manually restart Over temperature protection When the internal temperature is too high Energier Mobile will enter into the over temperature protectio...

Страница 14: ...ore flammable explosive or corrosive gases or liquids in the working environment Don t install in a working environment with metal conductive dust Please install the equipment in a location of dry cle...

Страница 15: ...step Step 1 Turn on the circuit breaker between the battery and the inverter Step 2 Press the On Off button to turn on the inverter entering into self diagnostic Step 3 Set the parameters following th...

Страница 16: ...Battery Battery Type AGM Battery AH 200AH Max Charge Current 100 of the Max charge current Absorption Voltage 14 1 Float Voltage 13 7 Undervoltage Protect Recover 13 0 Undervoltage Warning 11 0 Under...

Страница 17: ...2 5 2 2 TBB Link The TBB Link is a powerful tool or CC3 0L series inverter Configuration The TBB Link can be installed on the computer open the TBB Link and turn on the inverter the inverter can be co...

Страница 18: ...types AGM GEL OPZV Lead Carbon Li ion Flooded Battery Charge current 100A 150A Temperature compensation Yes General data AC Out Current 32A Transfer time 4ms 15ms when WeakGrid Mode Remote on off Yes...

Страница 19: ...Energier Mobile User Manual 14...

Страница 20: ...Energier Mobile User Manual 15...

Отзывы: