2.3.2 Professional Battery Charger for lead acid battery 

Multi stage sophisticated charging algorithm for lead acid battery 

Fitted  with  multistage  charging  algorithm  (bulk-absorption-float-recycle),  the  built-in  charger  of 
Energier  Mobile  is  designed  to  charge  battery  quickly  and  fully.  Microprocessor  controlled 
charging algorithm with variable absorption charging timer could guarantee the optimal charging 
for batteries of different discharged state.   

Battrry Voltage

Charge Current

Soft Start

Bulk

Absorption

Float

Recycle

Icc

11.5V

10 days

1h

5

mins

½ Icc

 

Figure 2-6 Multi stage sophisticated charging algorithm for lead acid battery 

Float charging and recycle charging program guarantee your battery getting proper maintenance 
in case of long time connected and less aging in case of long time connected with no use.   

Battery Sample Cable (Temperature and voltage) 

Battery temperature is a key factor in correct charging for lead acid battery, the charging formula 
must be adjusted (automatically and in real time) according to the actual battery temperature to 
ensure that battery is fully charged but not overcharged or  undercharged. All charging voltages 
recommended by battery manufacture are in fact ONLY applied at 20

-25

.   

The  Bat  sample  cable  (battery  temperature  and  voltage  sensor)  supplied  with  Energier  Mobile 
measures the temperature of battery and automatically makes adjustments at real time to properly 
charge your batteries at compensation rate of 

– 4mV/

/cell. In case of Bat sample cable is not 

present, Energier Mobile will use 25

 as default setting. This feature is especially recommended 

for sealed batteries and/or when important fluctuations of battery temperature are expected. 

Multi battery chemical available 

Energier  Mobile offers premium charging algorithm for commonly encountered lead acid battery 
chemicals  include  AGM,  GEL,  Flooded,  lead-carbon  and  Lithium  battery,  of  which  you  can  set 
through LCD interface and TBB Link software. 

2.3.3 Lithium Battery Compatible 

Energier  Mobile  support  universal  LFP  charging  profile  and  offered  pre-defined  LFP  charging 
profile for TBB M and P series lithium battery.   

Содержание Energier Mobile CC2.0L

Страница 1: ......

Страница 2: ...Energier MobileUser Manual...

Страница 3: ...Energier MobileUser Manual WARNING HIGH VOLTAGE INSIDE CAUTION THE DC FUSE MUST HAVE BEENTURNED OFF BEFORE SERVICING MADE IN CHINA...

Страница 4: ...ble for Energier Mobile Inverter Charger Combination This chapter contains important safety and operation instructions Read and keep this User Guide well for later reference The Energier Mobile Invert...

Страница 5: ...Remote control and monitor MCK 4 2 2 4 Connection compartment 5 2 2 5 Dimension 6 2 3 Function 6 2 3 1 Powerful and Reliable Inverter 6 2 3 2 Professional Battery Charger for lead acid battery 7 2 3 3...

Страница 6: ...ation otherwise the Energier Mobile Inverter Charger Combination would be overheating To avoid fire and electric shock make sure all cables selected with right gauge and being connected well Smaller d...

Страница 7: ...compressor power tool etc With the function of power assist power control it can be used to work with a limited AC source such as generator or limited grid Energier Mobile can automatically adjust its...

Страница 8: ...cture 2 2 1 Front Figure 2 1 Inverter Charger Combination structure in front view 2 2 2 Control panel Mode LED Indication ON OFF Power LED Indication Mute Unlock the fault and alarm Figure 2 2 Inverte...

Страница 9: ...ill flash when CC have warning Fault It will flash when CC have error 2 2 3 Remote control and monitor MCK Apart from above control panel the user is also allowed to monitor control and configure CC b...

Страница 10: ...A dry contact input for remote on off often IGN was connected Com MON RS485 port for external monitor such as MCK SNMP etc Com Sync Communication with TBB s M or P series lithium battery which is able...

Страница 11: ...utility grid Pure sine wave can guarantee the correct function of sensitive equipment computer laser printer TV etc Also your home appliances will work smoother cooler and more efficient such as fridg...

Страница 12: ...e charging formula must be adjusted automatically and in real time according to the actual battery temperature to ensure that battery is fully charged but not overcharged or undercharged All charging...

Страница 13: ...start automatically At this time the user needs to manually restart Over temperature protection When the internal temperature is too high Energier Mobile will enter into the over temperature protectio...

Страница 14: ...ore flammable explosive or corrosive gases or liquids in the working environment Don t install in a working environment with metal conductive dust Please install the equipment in a location of dry cle...

Страница 15: ...step Step 1 Turn on the circuit breaker between the battery and the inverter Step 2 Press the On Off button to turn on the inverter entering into self diagnostic Step 3 Set the parameters following th...

Страница 16: ...Battery Battery Type AGM Battery AH 200AH Max Charge Current 100 of the Max charge current Absorption Voltage 14 1 Float Voltage 13 7 Undervoltage Protect Recover 13 0 Undervoltage Warning 11 0 Under...

Страница 17: ...2 5 2 2 TBB Link The TBB Link is a powerful tool or CC3 0L series inverter Configuration The TBB Link can be installed on the computer open the TBB Link and turn on the inverter the inverter can be co...

Страница 18: ...types AGM GEL OPZV Lead Carbon Li ion Flooded Battery Charge current 100A 150A Temperature compensation Yes General data AC Out Current 32A Transfer time 4ms 15ms when WeakGrid Mode Remote on off Yes...

Страница 19: ...Energier Mobile User Manual 14...

Страница 20: ...Energier Mobile User Manual 15...

Отзывы: