Energier Mobile User Manual
7
2.3.2 Professional Battery Charger for lead acid battery
Multi stage sophisticated charging algorithm for lead acid battery
Fitted with multistage charging algorithm (bulk-absorption-float-recycle), the built-in charger of
Energier Mobile is designed to charge battery quickly and fully. Microprocessor controlled
charging algorithm with variable absorption charging timer could guarantee the optimal charging
for batteries of different discharged state.
Battrry Voltage
Charge Current
Soft Start
Bulk
Absorption
Float
Recycle
Icc
11.5V
10 days
1h
5
mins
½ Icc
Figure 2-6 Multi stage sophisticated charging algorithm for lead acid battery
Float charging and recycle charging program guarantee your battery getting proper maintenance
in case of long time connected and less aging in case of long time connected with no use.
Battery Sample Cable (Temperature and voltage)
Battery temperature is a key factor in correct charging for lead acid battery, the charging formula
must be adjusted (automatically and in real time) according to the actual battery temperature to
ensure that battery is fully charged but not overcharged or undercharged. All charging voltages
recommended by battery manufacture are in fact ONLY applied at 20
℃
-25
℃
.
The Bat sample cable (battery temperature and voltage sensor) supplied with Energier Mobile
measures the temperature of battery and automatically makes adjustments at real time to properly
charge your batteries at compensation rate of
– 4mV/
℃
/cell. In case of Bat sample cable is not
present, Energier Mobile will use 25
℃
as default setting. This feature is especially recommended
for sealed batteries and/or when important fluctuations of battery temperature are expected.
Multi battery chemical available
Energier Mobile offers premium charging algorithm for commonly encountered lead acid battery
chemicals include AGM, GEL, Flooded, lead-carbon and Lithium battery, of which you can set
through LCD interface and TBB Link software.
2.3.3 Lithium Battery Compatible
Energier Mobile support universal LFP charging profile and offered pre-defined LFP charging
profile for TBB M and P series lithium battery.