INPUT AND USE OF FREQUENCIES
and selection of variables
.
The icon “
1 2 3
” has been touched.
The arrows above the numerical block can be used to raise or lower the frequency value
displayed in increments of “DELTA F” set in window 1 of the tab SETUP.
If you want to use one frequency only, first touch the desired signal form (example
SQUARE WAVE) and then the icon “GO”.
The signal is delivered on both output ports for the time (example 02 : 30) set in window 1
of the tab SETUP.
The display shows
:
Continued on next page!
The frequency field shows ‘0’,
the numerical block awaits an
input of a frequency value within
the operational range of the
device between 0.1Hz and
15,000,000Hz.
Each digit entered appears in the
frequency field for review. In
case of an error enter zero in all
8 digit’s and start anew. Confirm
the correct value (for example
7,500Hz) with ‘E’.
7,500Hz in the frequency field.
Position ‘01’ of the operating memory.
A “STOP”-icon. A touch stops delivery.
A “SKIP”-icon. A touch stops delivery and
skips to.the next frequency stored (not shown
here).
The TIMER counting down from the original
02 : 30, now at 02 : 24. The total time for an
application of 3 frequency values (TT).
The signal form selected (black background)
and the PULSE – feature = OFF.
If the icon “PAUSE” is touched, it flashes,
delivery stops and the icon’s “SKIP” and
“STOP” disappear. The TIMER, now at 02 :
20, stops too.
Delivery continues if “PAUSE” is touched
again. The icon’s “STOP” and “SKIP”
reappear.
When the TIMER ends the display changes
back to the window of the tab “THERA”. The
icon “1 2 3” is touched again.