Wave form selection
The icon’s for wave form selection have a toggle function. Press once to activate, press
again to deactivate, and so on. Selection of a wave form is mandatory after entering a
random frequency or when using the memory function.
Example: The frequency 1,000Hz shall be sent to the output as a square signal:
1
&
0
&
0
&
0
&
E
To deactivate the output press
again.
The user can switch between wave forms any time.
Touch to
select a square wave output signal, completely DC-OFFSET, with a fixed
amplitude of 5Vpp.
The internal software activates this signal form at the start of a ZAPPER session.
Touch to
select a ‘FULL WAVE’ square output signal
. The amplitude can be adjusted with
the potentiometer between 0 and 27 Vpp. If the switch next to the potentiometer is set to it’s
bottom position, the output signal changes to
DC-OFFSET
. The amplitude can then be adjusted
with the potentiometer between 0 and 13.5 Vpp.
ALWAYS TEST A USER’S SENSITIVITY PRIOR TO AN APPLICATION OF SQUARE WAVE
SIGNALS
(not required for a ZAPPER session).
See chapter
Adjustment of amplitude
Touch to
select a sine wave output signal, completely DC-OFFSET, with a fixed amplitude
of 10Vpp.
The internal software activates this signal form at the start of an application if no other signal
form has been selected by the user.