![Taylor Wawa C708 Скачать руководство пользователя страница 48](http://html2.mh-extra.com/html/taylor/wawa-c708/wawa-c708_operators-manual_3802922048.webp)
44
Models C708 & C716
Operating Procedures
150622
Step 14
Place the agitator on the agitator drive shaft
housing. (See Figure 53.)
Figure 53
Note:
If agitator should stop turning during normal
operation, with
sanitized hands
, remove agitator
from agitator drive shaft housing and brush clean
with sanitizing solution. Install the agitator back onto
the agitator drive shaft housing.
Step 15
Remove the cotter pin from the pump. Remove the
feed tube and position it as shown in the illustration
below. Place the cotter pin in position on the outlet
fitting of the pump assembly.
(See Figure 54.)
Figure 54
Repeat these steps for the other side of the
Model C716.
Priming
Note: Use only FRESH MIX when priming the
freezer.
Step 1
Place an empty pail beneath the door spout(s). Pour
2-1/2 gallons (9.5 liters) of FRESH mix into the mix
hopper and allow it to flow into the freezing cylinder.
Step 2
Open the draw valve to remove all sanitizing
solution. When only fresh mix is flowing, close the
draw valve.
Note:
Momentarily open the center draw valve to
remove sanitizer from the center door spout (C716
only).
IMPORTANT! Failure to remove all sanitizing
solution may result in damage to the freezing
cylinder.
Step 3
When mix stops bubbling down into the freezing
cylinder, remove the cotter pin from the outlet fitting
of the mix pump. Insert the outlet end of the mix
feed tube into the mix inlet hole in the mix hopper.
Place the inlet end of the mix feed tube into the
outlet fitting of the mix pump. Secure with cotter pin.
Figure 55
Step 4
Select the AUTO key
.
Step 5
Fill the hopper with fresh mix and place the mix
hopper cover in position.
Repeat these steps for the other side of the
Model C716.