![Taylor Wawa C708 Скачать руководство пользователя страница 26](http://html2.mh-extra.com/html/taylor/wawa-c708/wawa-c708_operators-manual_3802922026.webp)
22
Models C708 & C716
Important: To the Operator
121008
To comply with health codes, heat treatment system
freezers
must
complete a heat treatment cycle daily
and
must
be disassembled and brush cleaned
according to the frequency specified by your
Federal, State, or local regulatory agencies. Please
consult your governing Food Code to determine the
maximum number of days allowed between brush
clean cycles.
Brush cleaning is the normal disassembly and
cleaning procedure found in the Operator Manual.
Failure to follow these guidelines will cause the
control to lock the freezer out of the AUTO mode.
If the Heat Treatment Cycle fails, the screen will
display a failure message and return the freezer to
the STANDBY mode.
Always comply with local guidelines for the
maximum number of days allowed between brush
clean cycles.
Freezer Locks
There are two types of freezer lock conditions that
can occur: Hard Lock or Soft Lock. A Hard Lock
requires the machine be disassembled and brush
cleaned. A Soft Lock can be corrected by either
disassembling and brush cleaning the machine, or
by starting another heat treatment cycle.
Hardlock
There are two causes of a hard lock failure. The
freezer will hardlock if either the Brush Clean Timer
has elapsed or if a Thermistor Failure (Freezing
Cylinder or Hopper) occurred during a Heat cycle.
1.
The following screen will be displayed if a Brush
Clean Cycle Time has occurred.
BRUSH CLEAN TIMEOUT
FREEZER LOCKED
CLEANING REQ'D
>
WASH TO BRUSH CLEAN
Touching the SEL key will display the following
screen.
FREEZER LOCKED
2.
The following screen will display if there has
been a thermistor failure (freezing cylinder or
hopper) during the heat treatment process.
SYSTEM FAULT
FREEZER LOCKED
SERVICE REQ'D
>
WASH TO BRUSH CLEAN
Touching the SEL key will indicate which thermistor
caused the Hard Lock.
HOPPER THERM BAD
FREEZER LOCKED
If the machine has hard locked and an attempt is
made to enter AUTO, the machine will enter the
STANDBY mode and display the following message.
FREEZER LOCKED
To restore the message that identified the reason for
the hard lock, turn the power switch OFF for five
seconds and then return the power switch to the ON
position. The original message with the reason for
the Hard Lock will be displayed.
The FREEZER LOCKED message will remain on
the display until the brush clean requirements are
fulfilled. The freezer must be disassembled in order
to activate the five minute timer on the display
screen. Once the timer counts down to zero, the
lockout is cleared.