![background image](http://html1.mh-extra.com/html/taylor/m8/m8_operating-manual_3756528012.webp)
V
-
21A
12
SETTING UP & WELDING
Set up the control unit at the place of work,
ensuring that the mains switch is in the OFF
position. Ensure that this is done in line
with the notes and safety
recommendations on pages 9 through 11 of
this guide.
Plug the controller into the correct mains
AC supply. The controller is rated for either
230V or 115V, check the rating plate and
ensure that the controller is plugged into
the correct supply before turning the
power on.
Connect the welding earth cables to the
controller socket marked
+
.
Note that the cable end plug has a peg
which mates with a key slot in the panel
mounted socket.
IMPORTANT !
Secure the connectors with
a clockwise turn until they lock. Failure to
do this will result in damage to the
connectors during welding.
Attach the welding earth clamps to the
work piece at approximately 180° to each
other. This will help to prevent "Arc blow"
when welding takes place. Prior to fitting
the clamps, ensure that the contact area of
the work piece is free from rust, paint,
grease etc. As this will result in a poor
welding connection and poor results.
Where possible, route the earth cables
away from the operator to prevent the operator being positioned between the run
of the cables whilst operating the equipment.
Содержание M8
Страница 30: ...V 21A 30 COMPONENT EXPLOSION 1 2 3 10 11 4 6 8 9 12 5 7 13 14 15 16 17 18...
Страница 35: ...V 21A 35 WIRING SCHEMATIC STANDARD CONTACT CONTROLLER MODELS M8 M9 M10...
Страница 36: ...V 21A 36 WIRING SCHEMATIC LIFT GAP CONTROLLER MODELS M8 M9 M10...
Страница 37: ...V 21A 37 WIRING SCHEMATIC CNC CONTACT CONTROLLER MODELS M8 M9 M10...
Страница 38: ...V 21A 38 WIRING SCHEMATIC CNC GAP CONTROLLER MODELS M8 M9 M10...