14
Model 432 Tim Hortons
Important: To the Operator
Power Switch
The center position is “OFF”. The left position is
“WASH”, which activates only the beater motor. The
right position is “AUTO”, which activates the beater
motor and the refrigeration system.
Reset Button
If an overload condition occurs, the freezer will
automatically stop operating. To properly reset the
freezer, place the toggle switch in the “OFF”
position. Wait two or three minutes and then press
the reset button. Place the power switch in the
“WASH” position and observe the freezer's
performance. Place the power switch in the “AUTO”
position.
Note: If the freezer is unplugged from the wall
receptacle, it will be necessary to press the reset
button for the freezer to operate once power is
re-established.
Display Light Switch
The display light switch is located under the control
channel. The left position is “OFF”. The right position
is “ON” and activates the display light.
Indicator Light - Spinner
The spinner indicator lights are located on the front
of the machine above the spinner assemblies. The
spinner indicator light is activated by pressing the
spinner motor switch. The light illuminates for 15
seconds, indicating the proper blend time.
Indicator Light - “Add Mix”
The ADD MIX indicator lights are located on the
front of the machine. An ADD MIX indicator light will
flash and an audible tone will sound when a mix
hopper has a low supply of product. Refill the hopper
as soon as possible.
Indicator Light - “Mix Out”
The MIX OUT indicator lights are located on the
front of the machine. When a MIX OUT indicator
light is flashing, it indicates that the hopper is empty
and the mix supply needs to be replenished. To
prevent damage to the unit, refrigeration stops
automatically. Refrigeration will restart 30 seconds
after the mix supply is replenished.
Viscosity Adjustment
The viscosity (thickness) of the slush can be
adjusted by turning the viscosity adjustment screw,
located under the control channel. Turn the viscosity
adjustment screw clockwise for a thicker product, or
counterclockwise for a thinner product. After making
an adjustment, allow the refrigeration system to
cycle 2 or 3 times to accurately evaluate the
viscosity.