B-210 / B-200 Curtis DC System Operator Manual
MB-210-14
X-Series Charger
Description of Operation
The X-Series chargers are designed as automatic chargers. The charger turns itself on when it
is plugged into the wall outlet and turns off when the batteries are fully charged.
There is a user interface on the charger. The interface consists of the following:
1. Start/stop switch: When pressed, the charging cycle will be terminated or restarted.
2. Charging status light: Indicates the current status of the charging cycle. The light will start
flashing when the charging cycle is started. It will stop flashing and remain ON when the
cycle has completed. Also used for fault indication along with the fault light (4).
3. Low voltage start switch: When pressed, will start the charge cycle if the battery voltage is
too low for an automatic start.
4. Fault light: Along with the status light (2), displays faults after self diagnosis is completed.
5. AC Circuit breaker: If circuit breaker trips, push it back in to reset. If it trips again, contact
qualified repair technician.
6.
Ammeter: Indicates the current flowing into the battery during the charging cycle.
7. Self diagnostic switch: Starts the charger self diagnosis procedure (details later in this section).
NOTICE
Sealed Lead Acid batteries (SLA) must be charged with a charger configured for SLA
batteries. Use of any other charger will result in damage and premature failure of the
batteries.
NOTICE
This charger is available for 115 VAC or 230 VAC operation (nominal). Confirm the
charger installed is correct for the AC voltage power source before connecting the charger.
Connecting to improper voltage will damage the charger.