Page 44
B-210 / B-200 Curtis DC System Operator Manual
MB-210-14
Signet Model HB Charger
The Signet® HB series chargers use a semi-automatic
charging system. The charger will turn itself ON when the
AC power cord is connected to the AC power source and
turn itself OFF when the batteries are fully charged. Refer to
the data plate on the charger for the voltage and type power
required for the charger.
There is a series of LED’s on the faceplate of the charger
that serve two functions:
1. Status of charge. The LED’s will display an approximate
percent of charge during the charging cycle. Refer to
the table below.
2.
Error condition. All three LED’s flashing is an indication
of a charging problem (charger will also be beeping).
Refer to the Charger Troubleshooting section for
information on error codes.
NOTICE
Sealed Lead Acid batteries (SLA) must be charged with a charger configured for SLA
batteries. Use of any other charger will result in damage and premature failure of the
batteries.
NOTICE
This charger is rated for 115 VAC or 230 VAC operation (nominal). When switching from
one input voltage to the other, wait until all LED’s are off. Switching voltage when any
of the LED’s are on will result in damage to the charger.
This charger requires a standard household 15 Amp electrical circuit. Before plugging
the charger in, confirm that your charging station is configured correctly.
DO NOT attempt to charge two vehicles on one standard household 15A circuit.
Failure to confirm the proper charging station configuration or attempting to charge
two vehicles may result in fire.
WARNING
Charging State
LED1
LED2
LED3
0 to 50%
Blinking
OFF
OFF
50% to 75%
ON
Blinking
OFF
75% to 100%
ON
ON
Blinking
Cycle complete
ON
ON
ON