background image

FITTING OPTION 1

1.

   Determine the correct position and orientation for the shower and screw the cranked connectors (2) into 

the appropriate water supplies finished with a ½” BSP female adapter (not supplied). Hot on the left, cold 

on the right with outlet positioned on the underside of body with SKN0601 or on the top of the body with 
SKN0706.

2.

  Screw the shrouds/flanges (1) onto the cranked connectors.

3.

  To fit the body onto the wall, place the washers (3) into the connecting nuts (4) and tighten to the cranked 

connectors (2). The connecting nuts (4) are secured to the mixer body by the retaining nuts (5). Note: No 
back nuts or fixing plates are supplied. This shower valve is clip mounted it needs to be connected to and 
supported by rigid pipe work.

TROUBLE-SHOOTING

If you require further assistance beyond the guide below contact the help line on  01225 303 900

AFTERCARE INSTRUCTIONS

Whilst this item has a high quality durable finish, it should nevertheless be treated with care.  Surfaces should 

be cleaned using only a soft damp cloth and clean water & dried using a soft cotton cloth.  Bath / shower 

cleaning products, even non-scratch ones could damage the finished surface.

MAINTENANCE

We advise that the valves, check valves and filters be regularly serviced particularly in hard water areas. The 

check valves along with the filters are contained in the retaining nut. The water supplies must be isolated 
remotely from the valve before removal. To access the check valves unscrew the connecting nuts joining the 

mixer to the cranked connectors. Unscrew the retaining nuts (left hand thread) from the mixer and check their 

conditions then reassemble and turn on water supply.

TMV2 approved valves shall be tested against the original set temperature results once a year. When testing is 

due the following performance checks shall be carried out.

1. 

Measure the mixed water temperature at the outlet.

2. 

Carry out the cold fail-safe shut off test by isolating the cold water supply to the TMV, wait for 5 seconds if 

water is still flowing check that the temperature is below 46 degrees C.

3. 

If there is no significant change to the set outlet temperature (+/- 2°C or less change from the original 

setting) and the fail safe shut off is functioning, then the valve is working correctly and no further service 
work is required.

If further maintenance should be required contact Tavistock for details.  Please see contact details on the back  

page of this document.

Problem

Shower will not run hot enough when first installed

Cold water running back through the valve into the hot 

water system.

Solution

Maximum temperature needs adjusting, see temperature 

setting guide

Check and clean the check valve cartridges and filters 

located under the check valves.

1

2

3

4

MAX

 

cut 

diameter = 45mm

KINETIC BOTTOM OUTLET BAR VALVE SHOWN

Содержание Kinetic SKN0601

Страница 1: ...for future reference KINETIC BAR SHOWER VALVE SKN0601 KINETIC BAR SHOWER VALVE SKN0706 TMV2 Buildcert Ref No RRTAV6 TMV2 Buildcert Ref No RRTAV7 REF KH TAV BSV10 07 10 V3 00 LOGIC BAR SHOWER VALVE SLG1302 LOGIC BAR SHOWER VALVE SLG1407 TMV2 Buildcert Ref No RRTAV13 TMV2 Buildcert Ref No RRTAV14 ...

Страница 2: ...nt deviation was recorded the test interval can be made equal to the maximum recorded interval to that point Note Check valve and strainer servicing must be conducted at each test interval If the recorded mixed water temperature is greater than 2 K from the initial recorded settings or the set point cannot be reached stabilised further action is required It is important to establish that the incom...

Страница 3: ...2 C of the initial maximum set point Restore the cold supply and measure the stabilised mixed water temperature This must not deviate by more than 2 C of the initial set recorded result Record these findings 5 Record the measuring equipment used for the measurements The above records must be retained and updated during the service life of the TMV If there is a residual flow during the commissionin...

Страница 4: ...es along with the filters are contained in the retaining nut The water supplies must be isolated remotely from the valve before removal To access the check valves unscrew the connecting nuts joining the mixer to the cranked connectors Unscrew the retaining nuts left hand thread from the mixer and check their conditions then reassemble and turn on water supply TMV2 approved valves shall be tested a...

Страница 5: ... threaded connector so the olive compresses and firmly locks the pipe in position Threaded connector Cranked connector Connecting nut Check valve Flow valve Retaining nut containing filters left hand thread KINETIC BOTTOM OUTLET BAR VALVE SHOWN KINETIC BOTTOM OUTLET BAR VALVE SHOWN ...

Страница 6: ...te the thermostat handle 5 until the desired hot water temperature is reached TMV2 regulations require a maximum temperature of no more than 44ºC 4 Replace the handle stop 4 with the stop lug positioned just to the right of the cartridge stop 6 See diagram below 5 Replace the handle 3 back onto the thermostat spindle 5 and secure via the handle arm 2 6 Test to ensure the desired maximum temperatur...

Отзывы: