K126MA
ENGLISH
CONTROL PANEL FOR ONE 18/24V MOTOR WITH ENCODER
• ABSORPTION CHECK FUNCTION
• STATUS OF INPUTS SIGNALLED BY LEDs
• INCORPORATED FLASHING CIRCUIT
• ENCODER SENSOR FOR SELF-LEARNING OF TRAVEL
• 433.92 MHz 2 CHANNEL BUILT-IN RADIO RECEIVER (CH)
• BATTERY CHARGER BOARD (INTEGRATED)
• DIAGNOSTICS OF MALFUNCTIONS SIGNALLED BY LED
• POSSIBILITY OF ENERGY SAVING OPERATION
ATTENTION:
- do not use single cables (with one single wire), ex. telephone cables, in order to avoid
breakdowns of the line and false contacts;
- do not re-use old pre-existing cables;
- we recommend to use the TAU cable code M-03000010C0 to connect the motors to the
control board.
INTRODUCTION
The K126MA board has two working modes, selectable through the J6 jumper (see wiring diagram).
J6 Jumped:
standard mode, i.e. the control unit is powered all the time;
J6 Not jumped:
low consumption mode, at the end of each maneuver the board automatically switches
OFF itself and all the auxiliary devices connected. The board will automatically switch
ON again activating the OP/CL contact or pressing the remote (mode where power is
supplied by other energy sources, ex. batteries charged by a photovoltaic panel).
Once the connection is achieved, in low-energy mode, press the PROG button briefly:
• All the green LEDs must be on (each of them corresponds to a Normally Closed input). The go off
only when the controls to which they are associated are operated.
• All the red LEDs must be off (each of them corresponds to a Normally Open input). The light up
only when the controls to which they are associated are operated.
TECHNICAL CHARACTERISTICS
Board power supply
13,5V
1
AC - 50 Hz
Max motor power DC
300VA - 18V
2
DC
Fast acting fuse for protection of input power supply 13,5V AC (F4 - 5x20)
F 16A
Fast acting fuse for battery charger protection (F5 - 5x20)
F 10A
Fast acting fuse for protection of auxiliary circuits 18V
2
DC (F3 - 5x20)
F 2A
Motor power supply circuits voltage
18V
2
DC
Auxiliary device circuits supply voltage
18V
2
DC
Logic circuits supply voltages
5V DC
Operating temperature
-20 °C ÷ +55 °C
1
18V for MASTER-
R and T-ONE8BR
2
24V for MASTER-R and T-ONE8BR
CONNECTIONS TO TERMINAL BOARD
Terminals Function
Description
FS1 - FS2
POWER SUPPLY
13,5V (18V for MASTER
-R and T-ONE8BR) AC control unit pow-
er supply input – Fed by
the toroidal transformer and protected
by the fuses on the 230V AC power supply.
1 - 2
AUX INPUT
external power input (ex. Photovoltaic system 12V DC).
Note: if this input is used, jump J7 appropriately (see wiring
diagram).
ATTENTION: POWERING THE CONTROL UNIT WITH AN EX-
TERNAL SOURCE, ALL THE OTHER 18V (24V for MASTER-
R) DC OUTPUTS BECOME THE SAME AS THE OUTSIDE
VOLTAGE.