22
K126MA
2
2 / 4 STROKE
On
when the automation is operating, a sequence of opening/closing com-
mands causes the automation to OPEN-CLOSE-OPEN-CLOSE, etc.
Off
in the same conditions, the same sequence of commands causes the
automation to OPEN-STOP-CLOSE-STOP-OPEN-STOP, etc . (step-by
step function) (see also dip switch 4).
3
CLOSES AGAIN
AFTER THE
PHOTOCELL
On
after the photocell is activated (input 7 - 9), the automation closes
automatically after 5 seconds.
Off
function off.
4
NO REVERSE
On
the automation ignores the closure command during opening and
auto-close time
Off
the automation responds as established by dip switch No. 2.
5
PRE-
FLASHING
On
the pre-flashing function is enabled.
Off
the pre-flashing function is disabled.
6
FOTOTEST
On
the “photocell test” function is enabled.
Off
the “photocell test” function is disabled.
Note: to be used when the photocells are not used.
7
MASTER/
SLAVE
On
enables the MASTER mode in the master/slave configuration (see T-
COMM instructions).
Off
enables the SLAVE mode in the master/slave configuration (see T-
COMM instructions), or standard operation (single motor).
8
BACK
JUMP
On
once reached the mechanical stop (either while opening or closing) the
operator will reverse slightly to avoid jamming between pinion and rack.
Off
function not activated.
9-10-11
Automation type selection
Dip 9
Dip 10 Dip 11 Automation
Off
Off
Off
TONE-5B
On
Off
Off
TONE-10B
Off
On
Off
TONE-8BR (24v)
On
On
Off
MASTER-R (24V Opening speed = Closing speed)
Off
Off
On
MASTER18QR
On
Off
On
MASTER-R (24V)
Off
On
On
CANTILEVER (light)
On
On
On
CANTILEVER TONE10B (heavy)
IMPORTANT: In case the automation type change, a new setting of the dips # 9, 10 and
11 will be required. Before the new setup, however, it is necessary to proceed to a HARD
RESET (see pag. 25) of the controller.
12
SENSITIVE
EDGE
On
RESISTIVE SENSITIVE EDGE (terminal No. 10).
Off
FIXED EDGE (NC contact – terminal No. 10).
Note: if not used, keep the DIP in the OFF position.
MEMORIZATION PROCEDURE
WARNING: After powering the control panel, wait 2 seconds before you start performing the
adjustment operations.
Note: the mechanical stops of the automation must be regulated both in opening and in clos-
ing [see motor instructions].
When you have completed the installation procedures:
Check the position of dip-switches 9, 10 and 11. Dip-switches must be set according to
the automation model (see table of dip-switches 9-10-11, “Logic adjustments” section).
It is recommended to start the learning process with the gate at 0,5 m from closing mechanical stop.
Press without releasing the PROG button till the DL8 LED starts flashing (yellow):
ENGLISH
Содержание K126MA