TERMINAL BOARD CONNECTIONS
Terminals
Function
Description
1 - 2
POWER SUPPLY POWER input 230/115 V AC 50-60 Hz.
EARTH
,
1= NEUTRAL, 2= PHASE;
3 - 4
FLASHING LIGHT FLASHING LIGHT Output FLASHING 230/115 VAC 50 W max. DIP6=ON fixed output during the operation, DIP6=OFF
intermittent output during the operation, the flashing frequency is doubled during closing;
5 - 6
LED
FLASHING LIGHT
FLASHING LIGHT Output FLASHING 12 VDC. Intermittent output during the operation, the flashing frequency is
doubled during closing;
7 - 10
OPEN/CLOSE
OPEN/CLOSE input (Normally Open contact);
8 - 10
STOP
STOP input (Normally Closed contact);
9 - 10
PHOTOCELLS
PHOTOCELLS OR SAFETY DEVICES input; active during closure (Normally Closed contact); the gate will stop during clos-
ing and totally reopen it, (10= Common).
If there is more than one safety device, connect all the NC contacts
IN SERIES.
11 - 12
24V AC
PHOTOCELLS
24 V AC 10 W output to Photocells, Receivers etc.; connect a up to 3 pair of photocells. 11= 0 V AC, 12= 24 V AC;
13 - 14
AERIAL
433,92 MHz built-in RX aerial input; 13= EARTH, 14= SIGNAL;
M2
LIMIT SWITCH
Quick coupling for LIMIT SWITCH connection (Normally Closed contacts)
.
ORANGE= Closing Limit Switch
(CLS), RED= Opening LimitSwitch (OLS), GREY= Common (COM);
FS1 - FS2
CAPACITOR
CAPACITOR Terminals for motor start-up;
M3
MOTOR
Quick coupling for 230 V AC single-phase MOTOR connection
. BLUE= common
(M-COM);
BROWN= closing
(M-CL); BLACK= opening (M-OP).
LOGIC ADJUSTMENTS
TRIMMER
FR.
Motor torque adjustment. Turning the trimmer clockwise (+) the torque will be increased; Turning the trimmer counterclockwise (-) the
torque will be decreased.
Note: The trimmer is set to provide sufficient thrust to work the gate within the limits established by current standards
(EN 12453).
SENS.
Obstacle detection setting
. Turning the trimmer clockwise (+) the sensitivity will be increased; Turning the trimmer counterclockwise (-)
the sensitivity will be decreased.
Note: Before setting the obstacle detection, let the gate operator perform a complete opening and closing cycle.
T.C.A.
Automatic closing time adjustment. Turning the trimmer clockwise (+) time will be increased; Turning the trimmer counterclockwise (-)
the time will be decreased.
Note: The time values can be set between 1 and 120 seconds.
Dip switch
1
AUTOMATIC
CLOSING
On automatic closing enabled.
Off automatic closing disabled.
2
2 / 4 STROKE
On
(with Automatic closing enabled) Two-Stroke operation mode OPEN-CLOSE, OPEN-CLOSE, etc
.
Off
(with Automatic closing enabled) Four-Stroke operation mode OPEN-STOP-CLOSE-STOP, OPEN-STOP-CLOSE-STOP,
etc
.
3
SOFT-STOP
On
Turning DIP3 ON, the setting of the travel with slowdown is activated (see following paragraph). At the end of the
procedure, leave the dip ON if you want to keep the values obtained. If you turn it OFF and then back ON, the
SETUP procedure must be repeated.
Off
The working time is determined by the limit switches, no slowdown. Non-adjustable maximum working time set at 96
seconds.
4
OPENING
DIRECTION
On
Left-hand leaf opening mode;
Off
Right-hand leaf opening mode;
5
NO REVERS
On While opening and during the T.C.A., the gate ignores the closing commands (NO REVERSE);
Off The gate behaves as per the setting of dip-switch 2;
6
BREAKING
On
breaking enabled;
Off
breaking disabled;
Note: the breaking system activates whenever the motor must stop and reduces the inertia accumulated by the gear motor during move-
ment.
SOFT-STOP SETTING
Set DIP3 to ON, active procedure (DL1 flashing) - Start with the sliding gate open
Close the AP/CH contact or press the OP/CL pushbutton: the operator will start closing the gate until the Closing Limit Switch (CLS) is reached.
Once the Closing Limit Switch (CLS) is reached, the operator will reverse the cycle and start opening the gate:
1_ Close the AP/CH contact or press the OP/CL pushbutton when the desired start point of the Soft-stop is reached;
2_ Once the Opening Limit Switch (OLS) is reached, the gate will stop. DL1 LED will turn ON (start point set);
3_ If the STOP contact is opened the procedure is interrupted, the gate will stop and DL1 LED will flash to advise that the procedure is still
active (Close the AP/CH contact or press the OP/CL pushbutton to restart the procedure from the beginning).
Note: SOFT-STOP settings apply both to opening and closing.
ATTENTION: to modify the SOFT-STOP settings it is necessary to repeat the whole procedure.
K100M FEATURES
DL1 LED
Other than indicating the programming of a transmitter is going on, DL1 LED advises error messages as follows:
Steady light:
Normal operation;
Fast flashing:
Soft-Stop learning procedure activated;
Slow flashing:
Automatic 50 / 60 HZ Frequency Detection Error;