RED LED – fault diagnostics
off
everything OK;
steadily lit
FAULTY battery (cell voltage < than the minimum or …..)
continuous flashing
short circuit
flashing every 2 seconds
battery not connected
AUTOMATIC OPERATION RESETTING - REALIGNMENT
When the board is powered or if the status of the inputs is unknown, the software must realign the
automation to determine the initial position.
The direction of the realignment depends on the program selected and the command given.
ATTENTION: if there are any “motor” alarms, the automatic reset timer is inhibited.
DIAGNOSTICS LEDs AND BUZZER
DL1
DIAGNOSTIC
DL2 - Red
POWER SUPPLY 12 V
DL3 - Red
POWER SUPPLY 5 V
DL4 - Red
AUX POWER SUPPLY 24 V DC
DL5 - Red
INSIDE SENSOR
DL6 - Red
OUTSIDE RADAR
DL7 - Green
PHOTOCELL 1
DL8 - Green
PHOTOCELL 2
DL9 - Green
EMERGENCY
DL10 - Red
CLOSE/LATCHING RELAY Pushbutton
DL11 - Green
INTERLOCK
DL12 - Green
SIDE SENSOR
DL13 - Green
STOP/ANTI-PANIC
DL14 - Red
Red LED for signaling MOTOR POWER SUPPLY 48V DC
DL1 LED ERRORS
Key:
LED steady on;
LED flashing
;
Automation warnings:
green - flashing every 4 seconds
automation closed – everything OK;
green - continuous flashing
automation moving (opening/closing);
green – quick flashing
automation pausing;
green – steadily lit
automation open;
/ alternating green/red - warning
setup to be performed
yellow – QUICK flashing
setup in progress
/
green/yellow – QUICK flashing
Parameter recalculation in progress / program change
Automation alarms:
DC19 -