![tau DC19 Скачать руководство пользователя страница 21](http://html.mh-extra.com/html/tau/dc19/dc19_installation-manual_821505021.webp)
21
“SOLO USCITA”
(
EXIT ONLY)
Exiting Traffic
Inside Radar
Close (Latching Relay)
Emergency
“ENTRAMBI I SENSI”
(AUTO)
Two-Way Traffic
Outside Radar
Inside Radar
Close (Latching Relay)
Emergency
“SEMPRE APERTA”
(
HOLD OPEN)
Door remains always open
“BLOCCATA CHIUSA”
(LOCK)
Door remains always closed Emergency
Emergency Input
works only when dip
# 1 on SW1 is set on
ON
“APERTURA INVERNALE”
(WINTER OPENING)
Incoming and outgoing
traffic, with partial opening
and closing
Outside Radar
Inside Radar
Close (Latching Relay)
Emergency
“APERTURA FARMACIA”
(PHARMACY OPENING)
Incoming and outgoing
traffic, with partial
“PHARMACY” opening
Outside Radar
Inside Radar
Close (Latching Relay)
Emergency
The control board
DC19 can be set up
to “pharmacy mode”
only through the
TLINETD device
CONNECTIONS TO TERMINAL BOARD
CONNECTOR J2
-
connection to TLINETD.
Terminals
Input/Output
Description
28
NEGATIVE T-LINETD POWER
- 5 V DC
29
B T-LINETD SIGNAL
signals the communication between T-LINETD and DC19
30
A T-LINETD SIGNAL
signals the communication between T-LINETD and DC19
31
POSITIVE T-LINETD POWER
+ 5 V DC
CONNECTOR J3 -
optional.
CONNECTOR J4 -
external accessory supply connection.
CONNECTOR J5 -
encoder connection.
CONNECTOR J6 -
transformer secondary connection.
CONNECTOR J7 -
motor connection.
CONNECTOR J8 -
input connection.
CONNECTOR J16 -
input connection.
CONNECTOR J17 -
connection to
TLINESELF
CONNECTOR
J4:
Terminals
Input/Output
Description
8 - 10
AUX. DEVICES
POWER SUPPLY
8 = 12V DC
9 = 24V DC
10 = - Common
CONNECTOR J8:
Terminals
Input/Output
Description
DC19 -
ENGLISH