![tau DC19 Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/tau/dc19/dc19_installation-manual_821505023.webp)
23
21 - 20
INTERLOCK
Closed
Prevents the opening of the other door when the
Interlock is operating
Opening
None.
Closing
None.
Open
None.
In pause
None.
22 - 20
SIDE SENSOR
(N.C.)
(20=
Common)
Closed
None.
Opening
Opening continues at reduced speed.
Closing
None.
Open
None.
In pause
None.
23 - 20
STOP/
ANTI-PANIC
(N.C.)
Closed
The door does not open so long as the input is busy.
Opening
It stops the automation.
Closing
It stops the automation.
Open
The door does not close so long as the input is busy.
In pause
The door does not open so long as the input is
busy. Once free, the door closes at reduced speed
after 5 seconds.
NOTE: The STOP lock/function blocks any movement in progress of the automation, while
the ANTI-PANIC lock/function stops the movement in progress of the automation and
then resumes with a slow closing once the function is restored.
N.B.: With DIP9 ON the input of terminal 25 (Stop / Antipanic) changes use. See Interlock Function.
CONNECTOR J17:
24 - 25
26 - 27
MECHANICAL SWITCH
24= Commun
25= Switch B0
26=
Switch
B1
27=
Switch
B2
Connections:
Selector
Control Panel
1
24
2
25
3
26
4
27
WARNING: In case neither the mechanical selector it is necessary to jumper wire
terminals 24 - 26.
SM
0419
M1
M2
1
2
3
4
HOLD OPEN =
Keeps door fully open.
WINTER OPENING =
To have a reduced aperture
.
AUTO =
All Opening Inputs enabled-
EXIT ONLY =
Disables Outside Radar.
LOCK =
Keeps door closed, allowing opening
only with EMERGENCY Input (with Dip
#1 on SW1 on ON).
CONNECTOR
J9 -
electric block connection
(12V DC).
CONNECTOR
J10 -
output connection.
DC19 -
ENGLISH