9
“SOLO USCITA”
(EXIT ONLY)
Exiting Traffic
Inside Radar
Start / PP
Emergency
“SEMPRE CHIUSA”
(HOLD CLOSE)
Door always closed
(time to exit 10 sec.)
Emergency
“MANUAL”
To move the door
manually without
controlling the motor
“SEMPRE APERTA”
(HOLD OPEN)
Door remains always
open
“SOLO ENTRATA”
(ENTRY ONLY)
Entering Traffic
Outside Radar
Start / PP
Emergency
CONNECTIONS TO TERMINAL BOARD
CONNETTORE J1
- power input connection 230V 50hz:
Terminals
Input/Output
Description
1
PHASE
230V AC
2
GROUND
3
NEUTRAL
230V AC
* On request 115 Vac +/- 10%, 60Hz
CONNETTORE J2
-
transformer primary connector.
CONNETTORE J3
-
transformer secondary connector.
CONNETTORE J4
- connector to link the two electronic boards
CONNETTORE J5 -
motor connection.
CONNETTORE J6
- terminal used to command an electric lock; to be combined with a relay
in order to activate the lock.
Terminals Function
Description
6 - 7
ELECTRIC LOCK
6= + 24V DC
7 = - GND
CONNETTORE J14
- connection for safety sensors test:
Terminals Function
Description
8-10
TEST SENSOR
8 = + 24V DC
10 = - GND
9
NOT USED
ENGLISH