8
CONTROL PANEL FOR AUTOMATIC SWING DOOR
• MICROPROCESSOR-BASED CONTROLLER
• ENCODER SENSOR FOR SELF-LEARNING OF TRAVEL
• CONNECTOR FOR BATTERY
• DIAGNOSTICS LEDS
ATTENTION:
- do not use single cables (with one single wire), ex. telephone cables, in order to avoid
breakdowns of the line and false contacts;
- do not re-use old pre-existing cables;
TESTING
Once the connection is completed:
TECHNICAL CHARACTERISTICS
Board power supply
230 V AC - 50 Hz*
Fast acting fuse entrance 230V AC (F5 - 5x20)
3.15A
Fast acting fuse for protection of auxiliary circuits 24 V CC
(F1 - 5x20)
2 A
Fast acting fuse for motor protection 40Vcc (F2 - 5x20)
6,3 A
Motor power supply circuits voltage
40 V DC
Auxiliary device circuits supply voltage
24 V DC
Logic circuits supply voltages
5 V DC
Operating temperature
-20 °C ÷ +55 °C
* On request 115 Vac +/- 10%, 60Hz
WORKING PROGRAMS
Six different working programs can be selected (can be set by mechanical selector or by
T-SIDETD programmer):
• “ENTRAMBI I SENSI” (AUTO)
• “SOLO USCITA” (EXIT ONLY)
• “SEMPRE CHIUSA” (HOLD CLOSE)
• “MANUALE” (
• “SEMPRE APERTA” (HOLD OPEN)
• “SOLO ENTRATA” (ENTRY ONLY)
Program
Description
Active inputs
Remarks
“ENTRAMBI I SENSI”
(AUTO)
Two-Way Traffic
Outside Radar
Inside Radar
Start / PP
Emergency
ENGLISH