BRINK Series - English
26
WARNING:
If digital selector DOORPROGB displays the following condition, it means that a
communication fault has been detected between the MASTER and SLAVE control
units. If this happens, check the connections of wiring WR3MS in both control units,
check the settings made on dipswitches 6 and 7 of S2 and reset the system.
If digital selector DOORPROGB is not used, lack of communication between the two
control units would be shown by the fact that the MASTER actuator would remain
open and the SLAVE closed.
14) PEDESTRIAN OPENING
The pedestrian opening function can only be used for a swing door with two wings. It is therefore essential for the actuators to be set up
for operation as a DOUBLE-WING DOOR (see sect.13).
To enable the PEDESTRIAN OPENING function, set dipswitch 4 of S2 ON and select the condition which activates the function by means
of dipswitch 3 of S2.
A)
DIP 3 S2 DIP
4
S2
OFF
ON
Choose
on the program selector to enable the PEDESTRIAN OPENING function.
- The
status loses its original free door function in this condition.
B)
DIP 3 S2 DIP
4
S2
ON
ON
Choose
on the program selector to enable the pedestrian opening FUNCTION.
- The
status loses its original mìnight lock function in this condition.
In both case A) and B), activation of an internal or esternal RADARinput partially opens the door, i.e. the sole wing controlled by the
MASTER actuator (pedestrian wing), while the START or EMERGENCY inputs open both MASTER and SLAVE wings.
Manual pushing with the push & go function only opens the pedestrian wing.
15) LIST OF PARAMETERS TO SELECT FOR THE CONTROL UNITS
PARAMETERS
DIP-SWITCH S1
MASTER
SLAVE
DIP 1 = PUSH & GO
•
•
DIP 2 = WIND STOP
•
•
DIP 3 = CYCLIC FUNCTION (repeated opening and closing)
•
DIP 4 = ELECTRO-LOCK OPERATING MODE
•
•
DIP 5 = MOTOR-POWERED CLOSING (BRINK-S version only)
•
•
DIP 6 = INITIAL SET-UP
•
•
DIP 7 = DOOR OPEN/NIGHT LOCK (with function selector switch on II)
•
DIP 8 = COURTESY MODE FOR THE DISABLEDI
•
DIP 9 = 10 sec OPENING WITH “NIGHT LOCK” WORK PROGRAM
•
DIP 10 = AUTOMATIC INCREASE OF THE HOLD TIME
•
DIP 11 = SELECTION OF THE FUNCTION SELECTOR DEVICE
•
DIP 12 = ADJUSTMENT OF FUNCTIONS & POTENTIOMETERS VIA SELECTOR DOORPROGB
•
•
DIP-SWITCH S2
MASTER
SLAVE
DIP 1 = STEPPING MODE
•
DIP 2 = ELECTRO-LOCK RELEASE IN FREE DOOR MODE
•
•
DIP 3 = PEDESTRIAN OPENING WITH FREE DOOR (OFF)/NIGHT LOCK (ON)
•
DIP 4 = PEDESTRIAN OPENING FUNCTION
•
DIP 5 = WING DELAY ON STARTING
•
DIP 6 = MASTER/SLAVE CONTROL UNIT SET-UP
•
•
DIP 7 = “DOUBLE-WING DOOR ” OPERATING MODE
•
•
DIP 8 = PHOTOCELL DOORFOTO1 OPERATING MODE
•
DIP 9 = PHOTOCELL DOORFOTO1 OPERATING MODE
•
DIP 10 = OPERATION OF THE RADAR INPUTS
•
DIP 11 = RESETTING OF TECHNICAL MENU DEFAULT VALUES (see TECHNICAL MENU)
•
•
DIP 12 = CONTROL UNIT RESET
•
ELECTRONIC SECTION