13
9. ANALYSIS AND RESOLUTION OF COMMON PROBLEMS
PROBLEM
ANALYSIS
RESOLUTION
Power failure in door opener
- Lacks power
- Blown fuse
- Faulty power supply
- Micro gearboxes contacts are not
restore
- Termal protection action
- Turn On
- Replace with equal fuse
- Check and connect line supply
- Progressively actuate the hand chain in both
directions to reset the micro gearbox contacts
-
Wait 20 min and restart the automation after
recovery of thermal protection
Shutdown problem limit switch
- Cam switch is not fixed regularly
- Faulty micro gearbox limit switch
- Fix the limit switch cams
- Replace the limit switch
In opening and closing the position
of the door is not correct
- Limit switch settings are not
correct
- Adjust the limit switch cams
The movement of the door is
opposite of the control operations
- The wiring of the motor phases
is wrong
- Reverse wiring of motor phases
The door does not stop in position
- The wiring of the motor phases
is wrong
- Reverse wiring of motor phases
Abnormal noise during the
operation of opening
- Overcharge or inappropriately
door installation
- Reduce the load or adjust the door
installation
10. MAINTENANCE
ATTENTION: no-one, except for the maintenance man, who must be a specialised technician, must be able to use the
automatic system during maintenance. Switch off the mains power supply to eliminate the risk of electrocution. If the power
supply must be left on for certain operations, each control device should be checked or disabled (remote controls, push
button strips, etc.) except for the one used by the maintenance man.
11. ORDINARY MAINTENANCE
Each of the following operations must be carried out when it feels necessary and always every 6 months:
Door:
General checking of the door
Automation system:
Checking safety devices
12. EXTRAORDINARY MAINTENANCE
If major work on electromechanical parts must be carried out, the faulty component should be removed and repaired in the
workshop by the maker’s or other authorised technicians.
13. GARANZIA: CONDIZIONI GENERALI
TAU guarantees this product for a period of 24 months from the date of purchase (as proved by the sales document, receipt
or invoice).
This guarantee covers the repair or replacement at TAU’s expense (ex-works TAU: packing and transport at the customer’s
expense) of parts that TAU recognises as being faulty as regards workmanship or materials.
For visits to the customer’s facilities, also during the guarantee period, a “Call-out fee” will be charged for travelling expenses
and labour costs.
The guarantee does not cover the following cases:
• formed according to the instructions provided by the company inside the product pack.
• If original TAU spare parts were not used to install the product.
• If the damage was caused by an Act of God, tampering, overvoltage, incorrect power supply, improper repairs, incor-
rect installation, or other reasons that do not depend on TAU.
• If a specialised maintenance man does not carry out routine maintenance operations according to the instructions
provided by the company inside the product pack.
• Wear of components.
The repair or replacement of pieces under guarantee does not extend the guarantee period.
In case of industrial, professional or similar use, this warranty is valid for 12 months.
english