![TASLER LTT500 Скачать руководство пользователя страница 51](http://html.mh-extra.com/html/tasler/ltt500/ltt500_manual_821036051.webp)
7. Device specific functions
Operation Manual Version 1.6
51
7. Device specific functions
In the last chapters we introduced the channel related functions. Now the global and device specific functions will
be explained.
7.1. Save configuration to device
One of the advantages from LTT500 universal amplifier is to use it mobile without PC.
To enable the computer independent mode (Stand-Alone), the device itself can keep one configuration in its
memory.
By switching on the LTT500, the device loads its internal saved configuration. The standard is the factory default.
The actual channel setup of the software will be transferred and saved on the LTT500 by the menu point „Device
– Save config to device“
. Before starting the transfer, a dialog popup which needs to be confirmed. This popup
window can be deactivated by the menu point
Device – Settings – Confirm save of configuration to device
.
Advice
: Please never interrupt the transfer of stand-alone setup to the device, by switching off the device or
interrupting the software. A corrupt transfer can interfere the stand-alone operation.