The TASKI vento 8/15 is a vacuum cleaner that is intended for commercial use 
(e.g. in hotels, schools, hospitals, factories, shopping centres, offices, etc.).
Under strict compliance with these Instructions for Use, it can be used for the 
dry cleaning of textile floor and wall coverings.
This machine has been exclusively designed for indoor use only.

Content

Safety instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

10

Translation of the original EU Declaration of Conformity . . . . . . . . . 

11

Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

11

Preparation for operation/Operation . . . . . . . . . . . . . . . . . . . . . . . . . . 

11

Beginning work . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

11

End of operation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

11

Service, maintenance and care  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

12

Malfunctions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

12

Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

13

Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

13

Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

13

General survey. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

13

Safety instructions

Due to their design and construction, TASKI machines comply with health and 
safety requirements of the EC guidelines and therefore carry the CE sign.

Important! Switch the machine off when you:
• e.g. carry out cleaning or maintenance work, or convert the machine to 

another function

• store it in a suitable room to avoid any unauthorised use of the unit
• leave it standing without supervision

Do this by pulling the power supply cord out of the mains socket.

Store the machine in a dry, dust-free room with a corrosion-free atmosphere.

The temperature must not fall below +10 °C or 35 °C. Low 

temperatures, damp and dust can significantly reduce the service life of the 

electrical components.

ATTENTION!

Before first start-up, it is essential that you 

read the instructions of use and the safety 

notes carefully.

Keep the instructions of use in an easily 
accessible place so that they can be consulted 
at any time.

Non-observance of this information can endanger people and / or 
cause servere damage!

Non-observance of this information can lead to malfunctions and 
property damage!

Important information about correct use. Non-observance of this 
information can lead to malfunctions!

Action points.

Modifications to this machine that have not been authorised by 
Diversey will lead to the cancellation of the Safety Marks and the 
CE Conformity. 
Any use of this machine other than its defined intended use could 
lead to injuries to persons and damage to the machine and the 
working environment.
In such cases, all guarantee and warranty claims will normally 
become null and void.

This appliance is not intended for use by persons (including 
children) with reduced physical, sensory or mental capabilities or 
lack experience and knowledge unless they have been given 
initial supervision or instruction concerning use of the appliance 
by a person responsible for their safety!

Children should be supervised to ensure that they do not play with 
the appliance.

Do not use the machine in rooms where explosive and flammable 
substances (e.g. petrol, thinners, heating oil, solvents, etc.) are 
stored or processed. The electrical or mechanical components of 
the machine could lead to ignition of these materials.

Do not use this machine to vacuum toxic, poisonous, caustic or 
irritating substances (e.g. acids, alkalis, hazardous dusts, etc.). 
The filter system will not adequately retain these kinds of 
materials. A possible impairment of the health of the user and of 
third parties cannot be excluded.

While operating the machine, take note of the surrounding area 
and pay particular attention to third parties and children!
In particular, the speed of the machine must be reduced in unclear 
situations, for example, near doors or curves .

STOP

t

STOP

STOP

STOP

STOP

STOP

In case of damage to parts that could affect safety, such as the 
tool cover, power supply cord or covers that prevent access to 
current-carrying parts, the operation of the machine must be 
stopped immediately!

Regularly check the power supply cord for tearing or aging, and 
do not put the machine into operation if it is not in a safe and 
suitable condition!

Caution:

Repairs to mechanical or electrical parts of the machine must only 
be undertaken by Diversey authorised customer service 
workshops or experts who are experienced in all relevant safety 
regulations.

Minimum requirement for the power supply cord H05VV-F2x1.0.

Caution:

This machine is only intended for use in dry areas, and must not 
be used or stored in the open air or under damp conditions.

Caution:

Pay attention to the accident prevention regulations!

Caution:

Only use tools which are specified in the instructions of use under 
accessories and which the TASKI-technical specialist 
recommends (Page 13), as the use of other tools could impair 
safety.

Caution:

Personal safety is covered by appropriate national regulations!

Caution:

It is forbidden to plug in or unplug the main power supply cord with 
wet hands!

Caution:

Take care not to damage the power supply cord by driving over it. 
Avoid crimping, tearing or damaging the power supply cord 
through heat, oil, or sharp objects!

Caution:

Please make sure that the voltage stated on the machine label is 
the same as the voltage rating of the plug socket!

Caution:

The additional power outlet (only vento 15) may only be used for 
additional equipment that is specified in the Instructions for Use 
(Page 13)!

Noise emission:

TASKI machines and units have been designed so that they 
present no danger to health through their noise emission accoring 
to the curent state of scientific knowledge. 
See the technical information on page 13.

STOP

STOP

To Order Parts Call 1-888-702-5326 - https://monsterfloorequipmentparts.com

Содержание vento 15

Страница 1: ... 8 15 V007 12089 22 1206 I18 I17 I16 tr sv sl pl no it hu fr fi es en de cz 12089 22 T o O r d e r P a r t s C a l l 1 8 8 8 7 0 2 5 3 2 6 h t t p s m o n s t e r f l o o r e q u i p m e n t p a r t s c o m ...

Страница 2: ... be supervised to ensure that they do not play with the appliance Do not use the machine in rooms where explosive and flammable substances e g petrol thinners heating oil solvents etc are stored or processed The electrical or mechanical components of the machine could lead to ignition of these materials Do not use this machine to vacuum toxic poisonous caustic or irritating substances e g acids al...

Страница 3: ... 220 240VAC 50 60Hz 900W vento 15 220 240VAC 50 60Hz 1150W Serial number see rating label at the machine Trademark Producer Techtronic Product Development Ltd 24 F CDW Building 388 Castle Peak Road Tsuen Wan Hong Kong Person authorised to compile the technical file Angelo Sabatino Diversey Europe B V Utrecht Zweigniederlassung Münchwilen CH 9542 Münchwilen Hong Kong 11 01 2012 This marking indicat...

Страница 4: ...The machine may only be operated with the filter disc fitted Place the ridge of the vacuum lid 2 into the guide provided on the canister 1 then press down until you hear the fastener catch click into place Heavily soiled exhaust filter Remove the exhaust filter and fit a new one Heavily soiled HEPA filter Vento 15 only Remove the HEPA filter and dispose it in accordance with the national regulatio...

Страница 5: ...ass II II Nr Article vento 8 vento 15 7514803 Disposable Fleece Dust Bags pack of 10 pieces 1 7514886 Disposable Paper Dust Bags pack of 10 pieces 1 7514804 Disposable Fleece Dust Bags pack of 10 pieces 1 7514888 Disposable Paper Dust Bags pack of 10 pieces 1 4091150 Filter disc X X 7514883 Exhaust Filter X X 7514884 HEPA Filter Kit includes exhaust filter X 7514885 HEPA filter reserve X 7514889 A...