background image

Nozzle must be inspected for proper operation and function according to this checklist before each use.
Check that:

1)

2)

3)

4)

5)

6)

7)

8)

There is no obvious damage such as missing, broken or loose parts, damaged labels etc.

Gasket grabber is free of debris.

Coupling is tight and leak free.

Valve operates freely through full range and regulates flow.

"OFF" position does fully shut off and flow is stopped.

Nozzle flow is adequate as indicated by pump pressure and nozzle reaction.

Shaper turns freely and adjusts pattern through full range.

Shaper turns into full flush and out of flush with normal flow and pressure restored.

10.0 INSPECTION CHECKLIST

Any Ultimatic, Mid-Matic or Handline nozzle failing any part of the
inspection checklist is unsafe and must have the problem corrected
before use. Operating a nozzle that fails any of the above inspections is a
misuse of this equipment.

WARNING

LIN-030 November 14, 2008 Rev 10

©Copyright Task Force Tips, Inc. 2002-2008

2351 Industrial Drive • Valparaiso , IN 46383-9511 USA

800-348-2686 • 219-462-6161 • Fax 219-464-7155

Made in USA • www.tft.com

TASK FORCE TIPS, Inc.

Содержание Ultimatic

Страница 1: ...on manual is intended to familiarize firefighters and maintenance personnel with the operation servicing and safety procedures associated with the Ultimatic Mid Matic and Handline fire fighting nozzle...

Страница 2: ...r or moderate injury 2 The member companies of FEMSA that provide emergency response equipment and services want responders to know and understand the following 1 Firefighting and Emergency Response a...

Страница 3: ...g pattern control from straight stream to wide fog Power fog teeth for full fill fog Gasket grabber inlet screen to keep large debris from entering nozzle Easily flushable while flowing to clear trapp...

Страница 4: ...p Line Orange Preconnect or discharge 2 Red Preconnect or discharge 3 Yellow Preconnect or discharge 4 White Preconnect or discharge 5 Blue Preconnect or discharge 6 Black Preconnect or discharge 7 Gr...

Страница 5: ...ing can occur If nozzle gets out of control or away from operator retreat from nozzle immediately Do not attempt to regain control of nozzle while flowing water 4 0 NOZZLE CONTROLS On models that use...

Страница 6: ...ing the STREAM SHAPER clockwise as seen from the operating position behind the nozzle moves the SHAPER to the straight stream position Turning the SHAPER counterclockwise will result in an increasingl...

Страница 7: ...hat fails inspection is dangerous to use and must be repaired before using Performance tests shall be conducted on the Ultimatic Mid Matic and Handline nozzle after a repair or anytime a problem is re...

Страница 8: ...o is an intended or unintended beneficiary of the equipment shall not be entitled to recover from TFT any consequential or incidental damages for injury to person and or property resulting from any de...

Страница 9: ...es in preconnect piping FLOW GPM 75 PSI 100 PSI 7 BAR ULTIMATIC 7 BAR ULTIMATIC ULTIMATIC 125 Flow Chart ULTIMATIC 125 Flow Chart 45M 45M 45M 60M 60M 60M 75M 75M 75M 8 6 24 41 21 34 17 31 15 5 28 14 1...

Страница 10: ...55 80 179 69 218 112 194 100 215 91 Flow Nozzle Reaction Chart Flow Nozzle Reaction Chart MID MATIC Flow Nozzle Reaction Chart Flow Nozzle Reaction Chart MID MATIC 7 BAR 7 BAR 7 BAR 7 BAR 7 BAR 7 BAR...

Страница 11: ...in each box indicates flow LPM and number on bottom indicates nozzle reaction KG 2 Flows may vary with brand or condition of hose 3 Flows are approximate and do not reflect losses in preconnect pipin...

Страница 12: ...e and nozzle reaction Shaper turns freely and adjusts pattern through full range Shaper turns into full flush and out of flush with normal flow and pressure restored 10 0 INSPECTION CHECKLIST Any Ulti...