2.2  VARIOUS MODELS AND TERMS

See fi gures 1A, 1B and 1C for views of the ZN, ZM  and Masterstream nozzles. The Masterstream Series Nozzle is available without 
halo ring. See catalog for model numbers and details.

Threaded Inlet

Stream Shaper / Bumper

Baffle

ZN NOZZLE

FIG 1A - ZN Nozzle

Halo Ring

Coupling

Stream Shaper / Bumper

Flow 
Selector

Jam Nut

Baffle

FIG 1B - Masterstream 1000 

Selectable Gallonage Nozzle

FIG 1C - Masterstream 1000 

Fixed Gallonage Nozzle

2.3  PATTERN CONTROL

TFT’s ZN, ZM and Masterstream nozzles have full pattern control from straight stream to wide fog. Turning the stream shaper 
clockwise (as seen from the operating position behind the nozzle) moves the shaper to the straight stream position. Turning the 
stream shaper counterclockwise will result in an increasingly wider pattern.

Since the stream trim point varies with fl ow, the stream trim point should be “trimmed” after changing the fl ow to obtain the straightest 
and farthest reaching stream. To properly trim a stream, fi rst open the pattern to narrow fog. Then close the stream to parallel to 
give maximum reach. Note: Turning the shaper further forward will cause stream crossover and reduce the effective reach of the 
nozzle.

Note: Masterstream models are also available with linear (push/pull), remote electric or hydraulic actuation of the stream shaper.

2.4  USE WITH FOAM

The ZN, ZM and Masterstream nozzles may be used with foam solutions. Refer to fi re service training for the proper use of foam.

WARNING

For Class B fi res, lack of foam or interruption in the foam stream can cause a break in the foam blanket 
and greatly increase the risk of injury or death. Assure that:  Application rate is suffi cient (see NFPA 11 
or foam manufacturer’s recommendations); Enough concentrate is on hand to complete task (see NFPA 
for minimum duration time requirements); Foam logistics have been carefully planned. Allow for such 
things as:  Storage of foam in a location not exposed to the hazard it protects;  Personnel, equipment 
and technique to deliver foam at a rapid enough rate;  Removal of empty foam containers;  Keeping clear 
path to deliver foam as hoses, other equipment and vehicles are deployed.

WARNING

Improper use of foam can result in injury or damage to the environment. Follow foam manufacturer’s 
instructions and fi re service training to avoid:  Using wrong type of foam on a fi re, i.e. Class A foam on a 
Class B fi re;  Plunging foam into pools of burning liquid fuels;  Causing environmental damage;  Directing 
stream at personnel.

WARNING

There is a wide variety of foam concentrates. Each user is responsible for verifying that any foam 
concentrate chosen to be used with this unit has been tested to assure that the foam obtained is suitable 
for the purpose intended.

Содержание MASTERSTREAM 1000 FIXED Series

Страница 1: ...el with the operation servicing and safety procedures associated with the ZN ZM and Masterstream firefighting nozzles This manual should be kept available to all operating and maintenance personnel ZN NOZZLE ZN NOZZLE 250 350 500 or 750 GPM 100 PSI 500 1000 1500 or 2000 LPM 7 BAR 700 KPA ZM NOZZLE ZM NOZZLE 500 750 1000 or 1250 GPM 100 PSI 2000 3000 4000 or 5000 LPM 7 BAR 700 KPA MASTERSTREAM 1000...

Страница 2: ... result in death burns or other severe injury FEMSA Fire and Emergency Manufacturers and Service Association P O Box 147 Lynnfield MA 01940 www FEMSA org Table Of Contents 1 0 MEANING OF SAFETY SIGNAL WORDS 2 0 GENERAL INFORMATION 2 1 USE WITH SALT WATER 2 2 VARIOUS MODELS AND TERMS 2 3 PATTERN CONTROL 2 4 USE WITH FOAM 2 4 1 FOAMJET LX WITH MASTERSTREAM NOZZLE 3 0 FLOW CHARACTERISTICS OF INDUSTRI...

Страница 3: ...to 135 F 40 C to 57 C for ZM nozzles WARNING Injury can occur from an inadequately supported nozzle The mounting must be capable of supporting the nozzle reaction force which can be in excess of 665 LBS 1250 GPM at 100 PSI WARNING Some volatile liquids can be ignited by static discharge Static build up can occur from Electrochemical separation of charge as water drains through low conductivity ref...

Страница 4: ...also available with linear push pull remote electric or hydraulic actuation of the stream shaper 2 4 USE WITH FOAM The ZN ZM and Masterstream nozzles may be used with foam solutions Refer to fire service training for the proper use of foam WARNING For Class B fires lack of foam or interruption in the foam stream can cause a break in the foam blanket and greatly increase the risk of injury or death...

Страница 5: ...determined fixed orifice The orifice size is not adjustable and is specified at time of order 250 350 500 or 750 GPM flow rates at 100 PSI are available on the ZN and 500 750 1000 or 1250 GPM 100 psi are available on the ZM nozzle The flow rate is marked on the nozzle s baffle Figure 3 gives relationship of flow and pressure for various orifice sizes 3 1 FLOW CHARACTERISTICS OF MASTERSTREAM 1000 S...

Страница 6: ...Masterstream Fixed Nozzle WARNING An inadequate supply of nozzle pressure and or flow will cause an ineffective stream and can result in injury death or loss of property 3 3 DETERMINING FLOW WITH PRE PIPED MONITORS The simplest procedure to determine flow is with a flow meter If a flow meter is unavailable then the flow may be estimated using pressure loss data between the nozzle and an in line pr...

Страница 7: ...stream nozzles at various pressures The graphs represent orifice sizes of 250 350 500 750 and 1000 GPM at 100 PSI For other orifice sizes and pressures the graphs may be interpolated Notes on trajectory graphs Graphs show approximate effective stream trajectory at 30 degrees elevation in no wind conditions Distance to last water drops approximately 10 farther Trajectories shown are for water The a...

Страница 8: ...emove debris trapped in the nozzle 1 Shut off flow to the nozzle 2 Move the stream shaper to the wide fog position 3 For ZN Nozzle Unscrew baffle using a 1 1 8 inch 28mm socket For ZM Nozzle Unscrew the bolt using 7 8 socket and remove baffle For Masterstream Selectable Gallonage Nozzle Turn flow selector on front of nozzle to FLUSH position For Masterstream Fixed Gallonage Nozzle Remove nozzle to...

Страница 9: ... PIN 1 Z660 3 BUMPER 1 Z700 9 NAME LABEL ZN NOZZLE 1 ZL150 4 SHAFT 1 Z505 10 GASKET 2 5 HOSE COUPLING 1 V3190 ZM NOZZLE 1 2 3 4 5 6 7 9 10 12 11 13 8 ZM PARTS LIST ITEM DESCRIPTION QTY PART ITEM DESCRIPTION QTY PART 1 GASKET 2 5 HOSE COUPLING 1 V3190 8 SPRING 1 ZFM580 2 NOZZLE BODY 2 5 NH 1 ZFM600NJ 9 BAFFLE K 125 1 ZFM560 3 CUP SEAL 4 25 X 4 75 X 1 4 1 XGE380 13 SUBBAFFLE K 75 K 100 1 ZFM5656 4 1...

Страница 10: ...32 X 3 16 DRIVE SCREW 1 VT02 00DS187 5 NAME LABEL 1 M750 24 O RING 345 1 VO 345 6 SHAPER 1 M216 25 CAM PINS 2 M260 7 HALO RING 1 M230 26 SELECT GAL BAFFLE 1 C027 8 HALO CAP 4 M231 27 SELECT GAL CAM US 1 C028 9 5 16 18 X 1 1 2 SOCKET HEAD SCREW 4 VT31 18SH1 5 28 SELECTABLE FLOW SPRING 1 C031 10 MASTER BUMPER 1 M700 29 I O SCREW 1 C033 11 GASKET 2 5 HOSE COUPLING 1 V3190 30 3 8 24 X 3 8 DOG POINT 2 ...

Страница 11: ...AM NUT 1 VT62 18NT 4 NAME LABEL 1 M755 19 WASHER 1 VW700X203 60 5 SHAPER 1 M216 20 10 24 X 1 2 BUTTON HEAD SCREW 1 VT10 24BH500 6 HALO RING 1 M230 21 3 6 BALL 48 V2120 7 HALO CAP 4 M231 22 WEAR STRIP 1 M510 8 5 16 18 X 1 1 2 SOCKET HEAD SCREW 4 VT31 18SH1 5 23 3 32 X 3 16 DRIVE SCREW 1 VT02 00DS187 9 MASTER BUMPER 1 M700 24 O RING 345 1 VO 345 10 GASKET 2 5 HOSE COUPLING 1 V3190 25 CAM PINS 2 M260...

Страница 12: ...urchase price of the equipment less reasonable depreciation in complete discharge of its obligations under this limited warranty If TFT makes this election claimant shall return the equipment to TFT free and clear of any liens and encumbrances This is a limited warranty The original purchaser of the equipment any person to whom it is transferred and any person who is an intended or unintended bene...

Отзывы: