TO THE USER

This equipment has been tested and found to com-
ply with the limits for a Class A digital device, pur-
suant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against
harmful interference when the equipment is operat-
ed in a commercial environment. This equipment
generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance
with the instruction manual, may cause harmful
interference to radio communications.
Operation of this equipment in a residental area is
likely to cause harmful interference in which case
the user will be required to correct the interference
at his own expense.

CAUTION
Changes or modifications to this equipment not
expressly approved by TEAC CORPORATION for
compliance could void the user's authority to oper-
ate this equipment.

For the consumers in Europe

WARNING
This is a Class A product. In a domestic environment, this
product may cause radio interference in which case the
user may be required to take adequate measures.

Pour les utilisateurs en Europe

AVERTISSEMENT
Il s'agit d'un produit de Classe A. Dans un environnement
domestique, cet appareil peut provoquer des interférences
radio, dans ce cas l'utilisateur peut être amené à prendre
des mesures appropriées.

Für Kunden in Europa

Warnung
Dies ist eine Einrichtung, welche die Funk-Entstörung nach
Klasse A besitzt. Diese Einrichtung kann im Wohnbereich
Funkstörungen versursachen ; in diesem Fall kann vom
Betrieber verlang werden, angemessene Maßnahmen
durchzuführen und dafür aufzukommen.

For U.S.A

DO NOT cut off the mains plug from this equip-
ment.

If the plug fitted is not suitable for the power

points in your home or the cable is too short to
reach a power point, then obtain an appropriate
safety approved extension lead or consult your
dealer.

If nonetheless the mains plug is cut off, remove the 
fuse and dispose of the plug immediately, to avoid 
a possible shock hazard by inadvertent connection
to the mains supply.

If this product is not provided with a mains plug, or
one has to be fitted, then follow the instructions
given below:

IMPORTANT:

The wires in this mains lead are coloured in

accordance with the following code:

GREEN-AND-YELLOW : EARTH
BLUE

: NEUTRAL

BROWN

: LIVE

WARNING:

This apparatus must be earthed.

As the colours of the wires in the mains lead of this appa-
ratus may not correspond with the coloured markings
identifying the terminals in your plug proceed as follows:

The wire which is coloured GREEN-and-YELLOW must
be connected to the terminal in the plug which is marked
by the letter E or by the safety earth symbol 

ç

or

coloured GREEN or GREEN-and-YELLOW.

The wire which is coloured BLUE must be connected to
the terminal which is marked with the letter N or coloured
BLACK.

The wire which is coloured BROWN must be connected
to the terminal which is marked with the letter L or
coloured RED.

When replacing the fuse only a correctly rated approved
type should be used and be sure to re-fit the fuse cover.

IF IN DOUBT — CONSULT A COMPETENT
ELECTRICIAN.

Important (for U.K. Customers)

This appliance has a serial number located on the
rear panel. Please record the model number and
serial number and retain them for your records.
Model number
Serial number

WARNING: TO PREVENT FIRE OR SHOCK

HAZARD, DO NOT EXPOSE THIS 

APPLIANCE TO RAIN OR MOISTURE.

The exclamation point within an equilateral triangle is intended to alert the user to the pres-
ence of important operating and maintenance (servicing) instructions in the literature
accompanying the appliance.

The lightning flash with arrowhead symbol, within equilateral triangle, is intended to alert
the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure
that may be of sufficient magnitude to constitute a risk of electric shock to persons.

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE  COVER
(OR BACK). NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALI-
FIED SERVICE PERSONNEL.

Ü

ÿ
Ÿ

Содержание DA-302

Страница 1: ...DA 302 Dual Digital Audio Tape Deck D00313200A OWNER S MANUAL...

Страница 2: ...e the fuse and dispose of the plug immediately to avoid a possible shock hazard by inadvertent connection to the mains supply If this product is not provided with a mains plug or one has to be fitted...

Страница 3: ...mast and supporting structure grounding of the lead in wire to an antenna discharge unit size of grounding conductors location of anten na discharge unit connection to grounding electrodes and requir...

Страница 4: ...ip playback 18 6 4 Single playback 18 6 5 Repeat playback 19 6 6 Program playback 19 Section 7 Recording editing of subcode data 20 7 1 Subcode data 20 7 2 Start ID 20 7 2 1 Recording the Start ID aut...

Страница 5: ...ol unit Owner s manual 1 2 Memory backup AUTO ID mode AUTO ID detection level memo point and menu setting data are all retained in the DA 302 s internal memory even when the power is turned off 1 4 Co...

Страница 6: ...agnetic field 2 2 Loading a DAT cassette 1 Press the POWER switch to turn the power on 2 Press the EJECT key to open the cassette holder 3 Load a cassette 4 Push the cassette holder to close it When e...

Страница 7: ......

Страница 8: ......

Страница 9: ...bing mode DUB MODE PGM Lights in the Program Dubbing mode DUB MODE APPEND Lights in the Append Dubbing mode 9 AUDIO ID Lights when the Start ID Auto Writing mode is selected 4 1 Front panel 1 POWER sw...

Страница 10: ...on for the deck selected by the SELECT 1 2 key REPEAT Lights in the One Program Repeat mode ALL REPEAT Lights in the All Program Repeat mode 8 COMMON MODE switch 1 2 Select to engage both Deck 1 and D...

Страница 11: ...ly released after about 8 minutes and the Stop mode is engaged To protect the heads the Record Pause mode is automatically released after about 8 minutes and the Sampling Monitor mode is engaged d REC...

Страница 12: ...d output analog signals from these connectors p 26 To select signals for output refer to Cas Out on the menu p 28 x DIGITAL connectors INPUTS 1 2 Digital input connectors for Deck 1 and Deck 2 OUTPUTS...

Страница 13: ...selected program number or to clear the numeric value for the memo point 5 MENU key Functions in the same way as when the MENU key is pressed while pressing the SHIFT key on the main unit 6 LOCATE ke...

Страница 14: ...signals 1 Set the COMMON MODE switch to OFF 2 Connect the source to the DIGITAL IN connector for the Deck 1 Deck 2 3 Set the INPUT switch to DIGITAL 4 Pressing the PLAY key while pressing the RECORD k...

Страница 15: ...d at high speed 4 times normal speed 4 When the DUBBING key is pressed the tapes in Deck 1 and Deck 2 are rewound then dubbing starts To stop dubbing in the middle press the STOP key on Deck 1 or Deck...

Страница 16: ...ual recording Continuous recording means recording one input source continuously using tapes in Deck 1 and Deck 2 1 Connect the input source to the ANALOG IN connec tors for analog input signals and t...

Страница 17: ...1 automatically rewinds the tape to the beginning either 3 minutes after the time set with Seqtime or when the tape end is reached 5 Deck 2 automatically rewinds the tape to the beginning either 3 mi...

Страница 18: ...One Program Repeat mode Set to All to engage the All Program Repeat mode If the STANDBY key is set to ON in the One Program Repeat mode the Play Pause mode is engaged at the beginning of the program a...

Страница 19: ...e 1 While holding the SHIFT key pressed press the AUTO ID key as many times as necessary to select the desired level 36 dB 42 dB 48 dB 54 dB dd 2 Release the SHIFT key to determine the level When dd i...

Страница 20: ...1 Select the deck with the SELECT 1 2 key 2 Press the ID MODE key so that the SKIP WRT lights on the display 3 During recording or playback press the EXECUTE key at the point where you want to record...

Страница 21: ...s of the setting of the SELECT 1 2 key 7 4 2 Erasing the End ID When the tape is fast forwarded by pressing the F FWD key the tape stops at the beginning of the End ID Recording from that point erases...

Страница 22: ...ously on a tape with the ABS time recorded fast forward the tape to the End ID or execute Blank Search p 25 to wind the tape to the point just before a non recorded section then start recording This e...

Страница 23: ...the key is shown in the program number display If the STANDBY key is set to ON the Play Pause mode is engaged after search 8 2 Skip search This allows you to set a memo point one point based on the A...

Страница 24: ...ape is rewound to the point just before the non recorded section and stops If the ABS time is recorded the ABS time can be record ed continuously from this non recorded section when recording starts W...

Страница 25: ...es the ABS time of Deck 2 of the master deck Deck 1 in the second deck receives the command from the EXT CONTROL IN connector and starts recording This process continues from deck to deck enabling con...

Страница 26: ...he other DA 302s to Slave Deck Set decks to master slave deck with Control in the menu P 28 3 For all connected DA 302s perform procedures 1 to 2 in the 6 2 Continuous playback 4 Press the REW key on...

Страница 27: ...press the MENU key to access the following menus 1 2 in the menu shows the deck selected by the SELECT 1 2 key Menu Group 2 In the normal time display mode press the MENU key while pressing the key t...

Страница 28: ...is possible Peak Hold Set the peak hold of the level meter to On or Off with the UP DOWN key When set to On the peak is held However the held peak level is reset if the MARGIN RESET key is pressed Di...

Страница 29: ...unbalanced FS 16 dB Maximum Output Level 6 dBV 2 0 V unbalanced 10 kohm load Output impedance Less than 1 kohm CASCADE OUTPUT RCA pin x 2 Normal Output Level 10 dBV 0 3 V unbalanced FS 16 dB Maximum O...

Страница 30: ...DA 302 External Dimensions DA 302 External Dimensions 482mm 19 57mm 2 3 16 132mm 5 3 16 150 5mm 6 3 32 456mm 18 330mm 13 17mm 11 16 6mm 1 4 432mm 17 70mm 2 13 16 201mm 7 15 16 20mm 13 16 2mm 1 8 0 5m...

Страница 31: ...s set to 1 2 e g The tape in Deck 1 stops at the beginning and Deck 1 s PLAY key is pressed while the tape in Deck 2 is being rewound TapeCut The tape is broken 12 1 Warning indications during operati...

Страница 32: ...NTROL connectors p 26 Specifications Analog input connector XLR 3 31 type x 2 2 hot Reference input level 4 dBu balanced FS 16 dB Input impedance More than 10 kohms Analog output connector XLR 3 32 ty...

Страница 33: ...Watford Herts WD1 8YA U K Phone 01923 819699 TEAC DEUTSCHLAND GmbH Bahnstrasse 12 65205 Wiesbaden Erbenheim Germany Phone 0611 71580 TEAC FRANCE S A 17 Rue Alexis de Tocqueville CE 005 92182 Antony Ce...

Отзывы:

Похожие инструкции для DA-302