Tarter CattleMaster 12 Series Скачать руководство пользователя страница 2

Hydraulic Chute

USAGE INSTRUCTIONS

2. Pre-Operation Check

•  Locate 110 volt electric cord on top 

of chute and plug into an outdoor, 

grounded, heavy-duty (10 or 12 

gauge) extension cord. 

WARNING

:

 Do not use a light-duty 

household or light-weight extension 

cord. Do not exceed 100 feet of  

extension cord. If gates or squeeze 

panels are sluggish or motor bogs 

down while attempting to operate, 

you do not have adequate power. 

This can be caused by and undersized 

extension cord or power outlet located 

too far from the main power supply.

•  Make sure all cords and plugs are out 

of the way of people and animals.

•  Plug chute into 110 volt outlet and let 

pump run a few minutes.

•  Test all three cylinders by operating all 

levers (opening and closing doors and 

squeeze chute) before loading animals.

1. Before Using Chute

•  Place CattleMaster

®

 hydraulic chute on level area.

•  Grease all zerk fittings on chute.
•  Spray aerosol oil on all latches,  

hinges and linkages.

•  Unscrew and remove plastic shipping  

plug from hydraulic fluid chamber.

•  Remove breather cap from plastic 

manual container on top of chute.

•  Screw breather cap with dipstick into  

hydraulic fill port and hand-tighten.  

CAUTION:

 Do not over-tighten or  

use any tools to tighten breather cap.

•  Check  

hydraulic fluid  

by unscrewing  

breather cap with dipstick. Fluid level 

should be at full mark on dipstick.  

If fluid level is low, add AW-32  

Premium Hydraulic Fluid.

•  Remove control levers from shipping  

bracket (black L-shaped bracket) by  

unscrewing nuts on 2 small  

bolts located on black L-bracket.  

Discard small bolts.

•  Unscrew the nuts on the 2 remaining  

long bolts located on the L-bracket.  

Discard the L-bracket.

•  Move control lever panel to where  

the levers are facing downward on  

the outside edge of the frame. The  

hole on the lever panel should line  

up with the holes from where short  

bolts were removed. Place long  

bolts into the aligned holes and  

hand-tighten nuts. Tighten both bolts  

and nuts.

3. Control Levers

Lever one 

(1) controls 

headgate 

operation

Lever two 

(2) controls 

squeeze 

operation

Lever three 

(3) controls 

tailgate 

operation

All levers work the same way.  Push  

handle in to close gates or tighten 

squeeze panel. Pull handle out to open 

gates or release squeeze panel.

Содержание CattleMaster 12 Series

Страница 1: ...Hydraulic Chute USAGE INSTRUCTIONS ...

Страница 2: ...id chamber Remove breather cap from plastic manual container on top of chute Screw breather cap with dipstick into hydraulic fill port and hand tighten CAUTION Do not over tighten or use any tools to tighten breather cap Check hydraulic fluid by unscrewing breather cap with dipstick Fluid level should be at full mark on dipstick If fluid level is low add AW 32 Premium Hydraulic Fluid Remove contro...

Страница 3: ...e and tighten the set screw cover D E F 5 Adjusting Hydraulic Cylinder Arms A To adjust hydraulic cylinder pull cotter pin out from grooved slot on clevis bolt located in center of the cylinder control arm B Pull clevis bolt out of cylinder control arm C Raise cylinder shaft upward until it is free from control arm The CattleMaster hydraulic chute has 3 fully adjustable hydraulic cylinder arms loc...

Страница 4: ...ght for locations of fittings C Check filter seasonally for buildup and wear replace filter after 5 000 hours of operation or if chute behaves erratically 7 Operation Catch D Partially open front headgate to allow animal s head through A Starting Position Squeeze panel open Front real gates closed B Open rear tailgate to allow animal to enter chute C Close rear tailgate to secure animal in chute E...

Страница 5: ...m on escape side and pull down on escape handle located on the control side Escape door will swing open To close door just bring in squeeze panel and door will slam shut 8 Adjusting Side Panels A Pull up on pin lever until lever is free of slot on adjustable floor B Push side of gate in or out as needed C Push lever down until it is securely locked into the selected slot on adjustable floor D If n...

Страница 6: ...turn tab down to lock panel in place Note To remove door completely open panel and slide to the side F Blinders located at the foot of the chute s exit reduces the animal s desire to lower their head G When the animal is in the chute and caught insert backup bar in horizontal opening of chute Once bar is secure in both sides slide bar forward in ratchets until it is against back of animal Backup b...

Отзывы: