DOMESTIC HOT WATER PIPING WHEN A SEPARATE DHW HEATER IS USED IN THE
SUMMER MONTHS (Fig . 3.4)
IN SUMMER: (or when the Solo Plus boiler is shut-down) CLOSE Valve B and OPEN Valve A.
IN WINTER: (or when the Solo Plus is in operation) OPEN Valve B and CLOSE Valve A.
Boiler Installation & Start-up > Installation of Optional Domestic Hot Water Coil
Page 25
NOTE
In certain areas, water supplies may have a high mineral content. This will lead to lime build-up
in the coil and blockage depending on the mineral content, boiler temperature, and the amount
of water passing through the coil. Coils should be cleaned or replaced as soon as there is any in-
dication that the hot water supply is being restricted. Coils can be cleaned with hydrochloric
acid, but is very dangerous and should be attempted only by qualified and experienced person.
Wood Boiler
Hot Water
Heater
Cold Water
IN
Hot Water
OUT
B
A
Tempering
Valve
100 Psi
Relief Valve
Fig. 3.4
Domestic Hot Water Piping