background image

3

 

1

 

 SUBJECT OF THE DOCUMENTATION

 

The  purpose  of  this  documentation  is  to  familiarize  the  user  with  the 
intended use of the structure, its principles of operation, and rules regarding 
handling  of  the  Tarasola-branded  product.  This  booklet  also  contains 
guidelines for use and service activities.

 

2

 

 PRODUCT IDENTIFICATION

 

The following describes a folding canopy with the trade name Tarasola Cubic. 
It  is  an  aluminum  structure  with  fabric  cover,  operated  by  automatic 
mechanisms.

 

 

 

Designed in accordance with the EU Council Regulation – CONSTRUCTION 
PRODUCTS.  When  properly  installed  it  can  withstand  the  wind  pressure 
equivalent to the 3

rd

 wind class, the criteria of which were established by 

the standard PN-EN 13561 + A.1: 2009 – EXTERNAL BLINDS AND AWNINGS 
- performance requirements including safety. This technical class ensures 
that the awning can withstand a wind pressure of 110 N/m

2

, equivalent to 

a  continuous  wind  pressure  of  49  km/h,  which  corresponds  to  6  in  the 
Beaufort scale.

 

 

The calculations concerning wind load resistance were performed according 
to  the  standard  PN  -  EN  1932:  2013  -  09  -  EXTERNAL  BLINDS  AND 
SHUTTERS - RESISTANCE TO WIND LOADS METHOD OF TESTING

 

and for 

structures with electric drive - Machinery Directive 2006/42/EC.

 

 

The canopy was designed as an external product, for wind, rain, and sun 
protection,  for  commercial  clients  as  well  as  for  residential  and  private 
buildings.

 

 

 

Operated by electric drives.

 

 

The structure may be enhanced with additional functionalities such as: heat 
radiators, glass walls, roller blinds, integrated lighting (additional products 
are  described  in  detail  in  a  separate  booklet),  creating  a  comprehensive 
design of a terrace canopy.

 

 

 

 

Familiarizing oneself with the manual shall ensure the proper functioning of 
the product.

 

 

 

Compliance with the guidelines therein shall ensure durability of the canopy.

 

Содержание Cubic

Страница 1: ...1 Tarasola Cubic TARASOLA CANOPY AND COMPONENTS USE AND MAINTENANCE MANUAL...

Страница 2: ...CATION 3 3 TECHNICAL SPECIFICATION 4 3 1 Structure 4 3 2 Wind class 6 3 3 Electrical components for Tarasola CUBIC 6 3 4 Fabric components in the canopy 8 3 5 Technical limitations of the fabrics 9 4...

Страница 3: ...nsures that the awning can withstand a wind pressure of 110 N m2 equivalent to a continuous wind pressure of 49 km h which corresponds to 6 in the Beaufort scale The calculations concerning wind load...

Страница 4: ...ort pillars aluminum leg profile together with an integrated water drainage system The number of supporting legs depends on the width of the module The supporting pillars are equipped with brackets in...

Страница 5: ...5 Fig 1 Graphical representation of the freestanding Tarasola Cubic structure Fig 2 Graphical representation of the Tarasola Cubic wall structure...

Страница 6: ...products we are offering a comprehensive product to our Clients the best on the market WARNING Due to the complexity and specificity of the product installation shall be performed by qualified personn...

Страница 7: ...ot recommended to connect more than one motor to one switch and vice versa The exception is having a switchboard Warning All wiring connection diagrams shall be obeyed otherwise warranty may be voided...

Страница 8: ...r shade or sunlight to shine through IN THE EVENT OF A FAILURE OF THE ELECTRICAL SYSTEM OF THE STRUCTURE IMMEDIATELY DISCONNECT THE MAIN POWER SUPPLY OF THE CANOPY AND REPORT THE FAILURE TO THE MANUFA...

Страница 9: ...care water light detergent soft cloth 3 5 Limitations of the fabrics Watertightness acrylic fabrics are not watertight They contain microscopic porous holes where the threads cross External impregnati...

Страница 10: ...closing of the canopy may overheat the electric drive thus activating the thermal switch which shall disconnect the power supply The motor shall remain off until the temperature is adjusted It is forb...

Страница 11: ...conifer needles and other type of waste from the gutters at least twice a year This shall help maintain the flow capacity of the gutters mounted in the supporting legs of the structure The manufacture...

Страница 12: ...ir channels forests trees with a risk of resin contamination and additionally it is not cleaned immediately after contamination then the profiles may get dirty making it impossible to clean them later...

Страница 13: ...c where the cord is not welded This however does not affect the appearance and functionality of the canopy Deviations of the profiles in relation to each other and the distance between them are permis...

Страница 14: ...14 5 CERTIFICATES...

Отзывы: