3. MAINTENANCE
Tapflo sanitary pump series
24
3.7.
T80-T425 – Disassembly of the pump
The numbers put in brackets, refer to the part numbers in the spare part drawings and spare
part lists in chapter 5 “SPARE PARTS”.
3.7.1.
Before the disassembly procedure
Be sure to drain all liquid from the pump. Cleanse or neutralize the pump thoroughly.
Disconnect the air supply and then the suction and discharge connections.
3.7.2.
Disassembly procedure
Fig. 3.7.1
Unscrew and remove two tri-clamps [138] connecting
the manifold [132] to the housings [11].
Fig. 3.7.2
Take off the manifold [132] and remove the valve balls
[23] and sealing [18].
Содержание Sanitary Series
Страница 44: ...6 DATA Tapflo sanitary pump series 44 ...