TapFlo CTM Series Скачать руководство пользователя страница 5

 

Instruction manual CTM mag drive pumps 

  

IOM manual Tapflo PE & PTFE series pumps 

1.5  

Example of installation

1)  YES: gate valve (may also be near pump in the case of long piping) 
2)  With positive head: tilt of piping towards pump  
3)  YES: line strainer if particles are present
4)  NO: air pockets: the circuit must be short and straight 
5)  YES: pipe fixing parts  
6)  Suction line as short and direct as possible
7)  YES:  check  valve  (especially  for  long  vertical  or  horizontal  pipes;  compulsory  with  parallel   

pumps)

8)  YES: adjusting gate valve on outlet  
9)  Bends placed after valves and instruments
10)  YES: attachment for gauge or safety pressure switch 
11)  NO: elbow joints (and other parts) on the pump (discharge and suction lines)
12)  With negative suction lift: tilt of piping towards suction tank
13)  YES: check valve (with negative suction lift)
14)  YES: strainer if particles are present
15)  Suction head varies according to flow in order to prevent windage
16)  Suction head  
17)  Immersion depth
18)  YES: expansion joint (indispensable with long pipes or hot liquids) and/or anti-vibration facility 

during discharge and suction; anchored near to pump

19)  YES: pipe discharge  (completely sealed), discharge valve shut during normal operations
20)  YES: overcoming obstacles at lower depths
21)  Fix the pump by the fixing holes provided: the supports must be level  
22)  YES: drainage channel around base  

 

1. INSTALLATION

1.6 

Instruments

In order to ensure a reasonable control of the performance and the conditions of the pump installed, we 
recommend using the following instruments:

-   a pressure-vacuum gauge on the suction piping;
-   a pressure-vacuum gauge on the delivery piping.

The pressure intakes must be made on straight pieces of piping at minimum five diameters from the 
pump inlets. The pressure gauge on delivery must always be fitted between the pump and the shutoff/
regulation valve. The output can be read on the pressure, transformed into meters and then compared 
with the typical curves. 

 

Electric power

The electric power absorbed by the motor can be measured with wattmeters. 

 

Optional instruments

The optional instruments can advise of abnormal operating conditions of pumps, such as: valves closed 
accidentally, missing liquid, overloads, etc. 

 

Thermometer

If the temperature of the pumped liquid can be a critical element, provide a thermometer (preferably 
on suction).

1.7 

Motor Connection

An expert electrician must always carry out the electrical connection. Compare the power supply with the 
data plate specifications and then choose a suitable connection. The type of connection is stated on the 
motor data plate that can be 

(star) or 

D

 (Delta), according to the power supply of the motor (see figure).

 

Star connection 

Delta connection 

D

Follow the prescriptions of the local electricity board for the connection. In no case connect the electrical 
motors directly to mains but also fit in between a suitable electric switchboard equipped with a knife 
switch and suitable safety devices. Safety devices against overloads must protect the motors. Make sure 
that the motor has suitable grounding and that it has been connected properly.

 

1. INSTALLATION

!

!

Содержание CTM Series

Страница 1: ...this instruction manual carefully before you install and operate the pump IOM MANUAL Instructions for installation operation and maintenance Mag drive centrifugal pumps Pump models CTM 20 7 CTM 25 8...

Страница 2: ...sembly and disassembly 13 3 3 1 Disassembly of the pump 13 3 3 2 Wear Parts Replacement 14 3 4 Assembly 14 3 4 1 Screws recommended locking torque 14 4 SPARE PARTS 15 4 1 Spare part drawing CTM pumps...

Страница 3: ...ce of high intensity magnetic fields This signal stands at points in this instruction manual of particular importance for compli ancewithregulationsanddirectives forcorrectworkflowandforthepreventiono...

Страница 4: ...llation place it in a clean location Do not remove the pro tective covers from the suction discharge and air connections which have been fastened to keep pump internals free of debris Make sure to cle...

Страница 5: ...mance and the conditions of the pump installed we recommend using the following instruments a pressure vacuum gauge on the suction piping a pressure vacuum gauge on the delivery piping The pressure in...

Страница 6: ...mperature or viscosity of the liquid stop the pump and get in touch with our technical service 2 1 2 Re starting after power shutoff In case of accidental stopping make sure that the non return valve...

Страница 7: ...e too high 25 Liquid temperature too low 26 Insufficient pressure or bushes flushing lubrication 27 Shaft is not straight 28 Static and rotating parts rubbing 29 Damaged impeller 30 Inner bushes worn...

Страница 8: ...TM 25 10 Screws and nuts M6 9 111 CTM 25 10 Screws M6 9 4 SPARE PARTS CTM 25 8 CTM 25 10 CTM 20 7 4 1 Spare part drawing CTM pumps 4 2 Spare part list CTM pumps Pos Description Pump model qty Material...

Страница 9: ...n Qty 1511 Rotating bushing front 1 1512 Rotating bushing rear 1 1521 Static bushing front 1 1522 Static bushing rear 1 Kit of O rings 1 O rings 18 1811 1812 1821 1822 4 4 Pump code The model number o...

Страница 10: ...Tapflo operative manuals Tapflo does not guarantee that the product will meet the precise needs of the Customer except for those purposes set out in any invitation to render documents or other documen...

Страница 11: ...grade the products from their normal purpose as described in the products operative manual without the prior written consent of Tapflo 8 Installation including electric and other connections to utilit...

Страница 12: ...22 Instruction manual CTM mag drive pumps IOM manual Tapflo PE PTFE series pumps 23 NOTES NOTES...

Страница 13: ...e perfect choice for your pumping needs Tapflo Fluid Handling India Private Limited Office No 207 Amar Neptune Baner Pune 411045 INDIA Phone 91 20 65000215 E mail ad tapflo in Web www tapflo in Kung l...

Отзывы: