TapFlo CTM Series Скачать руководство пользователя страница 11

 

20 

Instruction manual CTM mag drive pumps 

  

IOM manual Tapflo PE & PTFE series pumps 

21 

a new commencement of, the period of warranty.  Repair or replacement under the terms of this 
warranty may be fulfilled with functionally equivalent reconditioned units. Tapflo qualified personnel 
shall be solely entitled to carry out repair or replacement of faulty parts after careful examination 
of the pump.  Replaced faulty parts or components will become the property of Tapflo

7  The products are built in accordance with standard CE normative and are tested (where applicable) 

by Tapflo. Approval and tests by other control authority are for the customers account.  The products 
shall not be considered defective in materials, design or workmanship if they need to be adapted, 
changed or adjusted to conform to national or local technical or safety standards in force in any 
country other than that for which the unit was originally designed and manufactured.  This warranty 
shall not reimburse such adaptations, changes or adjustments, or attempt to do so, whether properly 
performed or not, nor any damage resulting from them, nor any adaptation, change or adjustments 
to upgrade the products from their normal purpose as described in the products operative manual 
without the prior written consent of Tapflo

8  Installation, including electric and other connections to utility mains according to Tapflo drawings, 

is for the cost and responsibility of the customer, unless otherwise agreed in writing.

9  Tapflo  will not be liable on any claim, whether in contact, tort, or otherwise, for any indirect, special, 

incidental, or consequential damages, caused to the customer or to third parties, including loss of 
profits, arising by any possible infringement of par. 3 above or by the customer or third parties being 
in the impossibility of using the products.

Steady the above,Tapflo liability to the customer or third parties from any claim, whether in contract, 
tort, or otherwise, shall be limited to the total amount paid by the customer for the product that caused 
the damages.

 

6.  WARRANTY & REPAIR

 

6.  WARRANTY & REPAIR

Company:

Telephone: 

Fax:

Address:

Country: 

Contact name:

E-mail: 

 

Delivery date: 

Pump was installed (date):

Pump type: 

Serial No (see name plate):

Description of the fault:

The installation

Liquid:

Temperature (°C): 

Viscosity (cPs): 

Spec. grav. (kg/m

3

): 

pH-value:

Contents of particles:                   %, of max size (mm):

Flow (l/min): 

Duty (h/day): 

No of starts per day: 

Discharge head (mwc): 

Suction head/lift (m):

Other:

Place for sketch of the installation

6.3 

Warranty form 

Содержание CTM Series

Страница 1: ...this instruction manual carefully before you install and operate the pump IOM MANUAL Instructions for installation operation and maintenance Mag drive centrifugal pumps Pump models CTM 20 7 CTM 25 8...

Страница 2: ...sembly and disassembly 13 3 3 1 Disassembly of the pump 13 3 3 2 Wear Parts Replacement 14 3 4 Assembly 14 3 4 1 Screws recommended locking torque 14 4 SPARE PARTS 15 4 1 Spare part drawing CTM pumps...

Страница 3: ...ce of high intensity magnetic fields This signal stands at points in this instruction manual of particular importance for compli ancewithregulationsanddirectives forcorrectworkflowandforthepreventiono...

Страница 4: ...llation place it in a clean location Do not remove the pro tective covers from the suction discharge and air connections which have been fastened to keep pump internals free of debris Make sure to cle...

Страница 5: ...mance and the conditions of the pump installed we recommend using the following instruments a pressure vacuum gauge on the suction piping a pressure vacuum gauge on the delivery piping The pressure in...

Страница 6: ...mperature or viscosity of the liquid stop the pump and get in touch with our technical service 2 1 2 Re starting after power shutoff In case of accidental stopping make sure that the non return valve...

Страница 7: ...e too high 25 Liquid temperature too low 26 Insufficient pressure or bushes flushing lubrication 27 Shaft is not straight 28 Static and rotating parts rubbing 29 Damaged impeller 30 Inner bushes worn...

Страница 8: ...TM 25 10 Screws and nuts M6 9 111 CTM 25 10 Screws M6 9 4 SPARE PARTS CTM 25 8 CTM 25 10 CTM 20 7 4 1 Spare part drawing CTM pumps 4 2 Spare part list CTM pumps Pos Description Pump model qty Material...

Страница 9: ...n Qty 1511 Rotating bushing front 1 1512 Rotating bushing rear 1 1521 Static bushing front 1 1522 Static bushing rear 1 Kit of O rings 1 O rings 18 1811 1812 1821 1822 4 4 Pump code The model number o...

Страница 10: ...Tapflo operative manuals Tapflo does not guarantee that the product will meet the precise needs of the Customer except for those purposes set out in any invitation to render documents or other documen...

Страница 11: ...grade the products from their normal purpose as described in the products operative manual without the prior written consent of Tapflo 8 Installation including electric and other connections to utilit...

Страница 12: ...22 Instruction manual CTM mag drive pumps IOM manual Tapflo PE PTFE series pumps 23 NOTES NOTES...

Страница 13: ...e perfect choice for your pumping needs Tapflo Fluid Handling India Private Limited Office No 207 Amar Neptune Baner Pune 411045 INDIA Phone 91 20 65000215 E mail ad tapflo in Web www tapflo in Kung l...

Отзывы: