background image

Owners Manual 

VNET

TM

SC1

VNET

TM 

SC1

(network enabled)

Содержание VNET SC1

Страница 1: ...Owners Manual VNETTM SC1 VNETTM SC1 network enabled ...

Страница 2: ...opriate parameters are grouped according to function For example the parametric equalisation page shows centre frequency width and gain Turning a parameter knob clockwise will increase the value of a parameter turning anti clockwise will decrease it Turning a knob rapidly will cause the action to accelerate so the value changes more rapidly MUTE BUTTONS The LEDs next to the mute buttons indicate t...

Страница 3: ...TRUCTIONS 5 PRODUCT FEATURE IDENTIFICATION 7 ACCESSORIES 8 HARDWARE OPERATION 16 SOFTWARE INSTALLATION 18 SOFTWARE OPERATION 24 PRODUCT DIMENSIONS 25 TECHNICAL SPECS 26 EQ AND FILTER RESPONSE GRAPHS 27 WARRANTY STATEMENT 29 DECLERATION ...

Страница 4: ...icing to qualified service personnel Service is required when the apparatus has been damaged in any way such as power supply cord or plug damaged liquid has been spilled or objects have fallen into the apparatus this apparatus has been exposed to rain or moisture does not operate normally or has been dropped SAFETY WARNING Permanent disconnection from the mains supply is to be achieved by removing...

Страница 5: ...omagnetic environments E2 E3 E4 Environment E1 domestic is specifically excluded FOR CUSTOMERS IN THE USA CANADA This product has been tested for electrical safety and complies with UL60065 7th edition CA CSA C22 2 No 60065 03 EMC This equipment has been designed to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasona...

Страница 6: ...top of the display when stepping onto an output EDIT PARAMETER SELECT BUTTONS The currently selected edit parameter page is displayed on the bottom left corner of the LCD Pressing the edit select buttons moves through the available parameters for the current input or output DISPLAY SCREEN Preset channel parameter and status information is shown on the 2x 24 character text display In most screens t...

Страница 7: ...An unbalanced input may be driven by connecting pin 3 cold signal to the ground connection of the unbalanced destination input Note that output pin 1 s are ground lifted at audio frequencies but connected to ground at RF for good EMC performance The intention being that the amplifiers the processor is driving should be responsible for the grounding of their input cable shields COMMUNICATIONS PORT ...

Страница 8: ...on networked SC1 direct communication via the PC SC1 can be made with a standard serial lead or USB RS232 cable OPTIONAL VNET INTERFACE POWER SUPPLY The PSU is only required when communication with a VNETTM network is by RS232 OPTIONAL RACK MOUNT KIT This 1U bracket allows you to rack mount up to three VNETTM interface accessories in a standard 19 equipment rack ...

Страница 9: ...stem e g Tannoy V SeriesTM USB to Serial interface allows networking of multiple VNET speakers or SC1 controllers USB to Serial interface allows networking of multiple VNETTM speakers or SC1 controllers Example 2 Using a Tannoy VNETTM SC1 with a powered loudspeaker system e g Tannoy PowerVTM VNETTM SC1 VNETTM SC1 ...

Страница 10: ... it was last powered down and the audio signal is gradually ramped up to its correct level CREATING A CROSSOVER The unit has two Base Presets mono and stereo These Base Presets are stored in locations 1 and 2 respectively they can be used to develop settings for any loudspeaker combination They are recalled in the following way Press Recall and use the left hand parameter knob A to scroll through ...

Страница 11: ... Preset that is stereo linked the channel selection will reflect this For example 1 4 indicates outputs 1 and 4 When navigating onto an output channel the usage of the output as define in the Factory Preset will be shown briefly at the top of the screen Pressing the edit navigation buttons gives access to the various pages of parameters available for each channel The currently selected page is sho...

Страница 12: ...a basic or user Preset has been recalled a user has complete freedom to adjust any or all of the parameters PRESET STORE To store the current Preset in a user location press the Preset Store Button so the indicator above it illuminates Turn the first parameter knob until the required Preset location number is show on the display A Preset name of up to 12 characters in length can be entered using p...

Страница 13: ...ters of each member of the pair being identical The routing of inputs to outputs is fixed This format is intended for symmetrical stereo operation eliminating the need to make identical parameter adjustments for each channel The channel pairing is Left and Right Inputs Outputs 1 routed from L input and 3 routed from R input Outputs 2 routed from L input and 4 routed from R input Outputs 3 routed f...

Страница 14: ...eeper rather than following a linear slope so a dB octave description is not accurate Parametric Equalisation Eight sections of equalisation are provided two shelving filters and six fully variable parametric sections High and Low shelving filters The frequency is specified as point where the filter deviates by 3dB from the gain value Parametric filters 13 Knob A Gain adjustable in 0 2dB steps fro...

Страница 15: ...tion limiter is provided on each output Threshold is user adjustable all other parameters are carefully calculated dependant on configuration to provide clean and effective control of signal dynamics 14 Knob A Frequency out 10 0Hz to 25 6kHz out Knob B High pass filter type Knob A Gain adjustable in 0 2dB steps from 80 dB to 20dB Knob B Polarity selectable normal or reversed with reference to othe...

Страница 16: ... the base contrast of the screen and also allows optimization for a given viewing angle Parametric equalisation width parameters can be displayed in either Q or bandwidth expressed in octaves Care should be taken when swapping between mono and stereo mode as the parameter set for the left hand channels will be copied to the right hand side overwriting those settings This is not reversible and coul...

Страница 17: ...ou already have the NET Framework 1 1 installed by clicking Start on your Windows desktop selecting Control Panel and then double clicking the Add or Remove Programs icon When that window appears scroll through the list of applications If you see Microsoft NET Framework 1 1 listed the latest version is already installed and you do not need to install it again COMPUTER SYSTEM REQUIREMENTS Microsoft...

Страница 18: ...D contents Double click on the Setup exe icon The welcome screen will appear Click Next 2 Select your destination Folder Click Next 3 Confirm Installation Click Next 4 If you accept the licence agreement check I Agree and Click Next 5 The programme will begin installing 6 Installation Complete ...

Страница 19: ...ar buttons See Toolbar TOOLBAR The toolbar provides the following one click functions Open Opens a file which contains parameters for the device A dialogue will appear inviting you to choose a file to open Save Saves the current settings If you have previously opened or saved a file the configuration will be saved in the same file name otherwise a dialogue will appear inviting you to enter a file ...

Страница 20: ... stored parameters in the devices thus retaining synchronisation When a file is opened online the new settings are not only set in the control panel they are also transferred to the device CONTROLLING DEVICES When online the tree menus will show the connected VNET speakers or SC1 s on the network FIG 2 Double clicking on the model on the tree view will open the control panel for each respective de...

Страница 21: ...hown allowing you to scroll up and down the list by clicking the scroll arrows Note that once the control is highlighted the PGUP PGDWN and Arrow keys or the mouse wheel may also be used to change the selection SPIN BOXES The value would normally be adjusted by clicking on the top button to increase the displayed value or on the bottom button to reduce the displayed value Holding the mouse button ...

Страница 22: ...ut CTL Z Undo On Drop down Spin Push Fader controls PgUp Increase value coarsely PgDown Reduce value coarsely Up Right arrow Increase value finely Down Left arrow Reduce value finely On push button controls Space Activate AUDIO PROCESSING SC1 provides the following processing options Crossover filtering with frequency variable over the range 10Hz to 25kHz and Out with the following alignments 1st ...

Страница 23: ...rossover alignments without any additional group delay This allows a lower order filter to be used without sacrificing cut off characteristics but with smoother group delay and less severe phase penalties giving a more natural sound Hardman filters and also provide identical phase characteristics between adjacent bands like Linkwitz Riley so the polar performance is rock steady We also employ phas...

Страница 24: ...ge will appear 4 Click OK 5 Browse to the new firmware file select The following message will appear stating the old version number the replacement version number 6 Click OK 7 In order for the new firmware to take effect the unit has to be switched off back on again This can be done automatically after the update Click OK to confirm 8 At the bottom right hand side of the screen a blue bar will sho...

Страница 25: ...24 PRODUCT DIMENSIONS 482mm 19 0 435mm 17 3 45mm 1 8 254mm 10 ...

Страница 26: ...to 25 4kHz 1 36 octave steps LP filter frequency 10Hz to 25 4kHz and off 1 36 octave steps LP HP filter type 12 18 24dB octave Bessel and Butterworth 12 24 and 48dB octave Linkwitz Riley 4th or 8th order Hardman Delay Input 400ms output 80ms Limiter High performance limiter adjustable threshold in 0 2dB steps automatic time constants EQ frequency 10Hz to 25kHz 1 36 octave steps EQ gain 15dB to 15d...

Страница 27: ... 104 12B Oct 24dB Oct 48dB Oct Magnitude dB Frequency Hz Bessel 6 0 6 12 18 24 30 36 6dB Oct 12dB Oct 100 1 103 1 104 Magnitude dB Frequency Hz Hardman 6 0 6 12 18 24 30 36 100 1 103 1 104 4th Order 8th Order Magnitude dB Frequency Hz Shelving EQ 15 10 5 0 5 10 15 Low Shelf Varying Gain High Shelf Varying Slope 100 1 103 1 104 Magnitude dB Frequency Hz Butterworth 15 10 5 0 5 10 15 100 1 103 1 104...

Страница 28: ...lowing apparatus is are manufactured in UK for Tannoy Ltd of Rosehall Industrial Estate Coatbridge Scotland ML5 4TF The following equipment is marked with the CE label and conform s to the protection requirements of the European Electromagnetic Compatibility Standards and Directives The apparatus is designed and constructed such that electromagnetic disturbances generated do not exceed levels allo...

Страница 29: ...28 NOTES ...

Страница 30: ...29 NOTES ...

Страница 31: ...30 NOTES ...

Страница 32: ... T 00 1 519 745 1158 E inquiries tannoyna com Tannoy Deutschland T 00 49 0180 1111 881 E info tannoy com Tannoy France T 00 33 0 1 7036 7473 E ventes tannoy com Tannoy adopts a policy of continuous improvement and product specification is subject to change REVISION DATE 5 Mar 07 6481 0507 ...

Отзывы: