manualshive.com logo in svg
background image

C

M

Y

CM

MY

CY CMY

K

4

INSTALLATION INSTRUCTIONS

1

THIS PRODUCT MUST BE EARTHED. Use only a flexible cable or cord provided with a green or green and yellow core
which must be connected to the protective earthing terminal of the detachable Neutrik ’Powercon’ type NEC3FCA 
connector (Tannoy part number 3461 0919 as supplied with the equipment. The other end of the green or green and 
yellow conductor must be connected to the earthing pin of a suitable mains plug or the earthing terminal of the installation.
The cord must be of maximum length 7.5 meters, rated SJ, SJT, or SJE, 10A minimum and be marked VW-1.

2

The electrical power connection to this product is only to be made via a detachable Neutrik ’Powercon’ type NEC3FCA 
connector (Tannoy part number 3461 0919) as supplied with the equipment.  Wiring to this connector must only be made
by suitably qualified personnel and must comply with all local requirements.

3

Do not install this equipment in an enclosed space. Do not limit free ventilation and movement of air around the back 
panel. Ensure that there is at least 100mm (4") of space around all sides of the product for ventilation.

4

Only use attachments and accessories approved by or specified by Tannoy.

FOR CUSTOMERS IN EUROPE

This product complies with both the LVD (electrical safety) 73/23/EEC and EMC (electromagnetic compatibility) 89/336/EEC
directives issues by the commission of the European community.

Compliance with these directives implies conformity with the following European standards:

EN60065

Product safety

EN55103-1

EMC emissions

EN55103-2

EMC immunity

This product is intended for the following electromagnetic environments: E2; E3 & E4. Environment E1 (domestic) is specifically
excluded.

FOR CUSTOMERS IN THE USA & CANADA

This product has been tested for electrical safety and complies with:

UL60065 7th edition
CA /CSA C22.2 No.60065-03

EMC

This equipment has been designed to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a
commercial environment.

Industry Canada Class A emission compliance statement: This Class B digital apparatus complies with Canadian ICES-003.
Avis de conformite’ a’ la re’glementation d’Industrie Canada. Cet appareil nume’rique de classe A est conforme a’ la norme
ICES-003.

2.0: INTRODUCTION

Tannoy has integrated the Dual Concentric“ point source, constant directivity drive unit with leading edge digital signal
processing, network control and class D amplifier technologies to create 

VNET“

. High definition sound reinforcement (HDSR“)

loudspeakers designed to form the complete installation solution. Close integration and proximity of the main system elements
has many advantages, and permits the amplifiers, processing, monitoring and drivers to perform as a unified whole. The
resulting package is a very high performance loudspeaker with intuitive user setup, integrated processing, tuning control,
performance diagnostics and protection. Class D power amplification with a switched mode power supply is very efficient,
flexible and reliable. Little is required in the way of heat sinking and no fans are required. The small control panel on the rear
of the cabinet is all the surface area that is needed for cooling, allowing the unit to operate at a low temperature, even when
driven at very high power levels. The digital electronics (DSP) also use switched mode regulators to further improve efficiency
and enhance design synchronicity of the entire package.

The Tannoy 

VNet

 Range of professional loudspeakers have been designed for a wide variety of sound reinforcement applications

requiring extended frequency response from a powerful yet compact system, capable of delivering high sound pressure levels
with extremely low distortion, resulting in outstanding clarity, definition and detail.

The Tannoy 

VNET12

 comprises one 12 inch Dual Concentric driver, in which the low frequency (LF) and high frequency (HF)

sources are coincidentally aligned to a point source, resulting in a smooth uniform frequency response over a wide area of
coverage either as a portable stand alone system or in a multi-cabinet array. The sophisticated CAD designed waveguide
combines conical dispersion and excellent acoustic impedance characteristics. As the system is a point source, clusters and
arrays have minimal lobing. These features are inherent and achieved without the use of any electronic signal processing.

Содержание VNET 12

Страница 1: ...Owners Manual VNET 12 VNET 12 HP VNET 15 VNET 300 VNET 15 HL VNET 15BP VNET 18DR TM...

Страница 2: ...nking cabinets 7 0 SOFTWARE INSTALLATION 8 0 SOFTWARE OPERATION 8 1 Updating firmware 9 0 EQUALISATION 10 0 ARRAYING 11 0 DIMENSIONS 12 0 PERFORMANCE DATA 13 0 TECHNICAL SPECIFICATIONS 14 0 RIGGING 14...

Страница 3: ...mally or has been dropped SAFETY WARNING Permanent disconnection from the mains supply is to be achieved by removing the supplied cord connector from the back of the unit SAFETY WARNING Do not remove...

Страница 4: ...emission compliance statement This Class B digital apparatus complies with Canadian ICES 003 Avis de conformite a la re glementation d Industrie Canada Cet appareil nume rique de classe A est conforme...

Страница 5: ...quired to configure the network nodes Each loudspeaker in the system can be individually optimized and acoustically profiled taking into account its exact position within the venue relative to the roo...

Страница 6: ...ch levels over 95dBspl for 8 hours per day can eventually cause permanent hearing loss Since Tannoy loudspeakers have a natural sounding flat frequency response and low distortion it s possible not to...

Страница 7: ...gth of time reduce the gain Fast regular flashing of the red LED indicates that the DSP is taking protective action the input will be automatically attenuated to avoid over driving if this occurs the...

Страница 8: ...manual extensive testing was carried out with the following devices Tannoy USB RS485 Converter Part No 8001 3920 K2 from KK www kksystems com USB COMi from Easysync www easysync co uk 485 SD9R from B...

Страница 9: ...Volts on the network Link connector that can be used to seamlessly power network extenders or repeaters that large networks may require This power can be located on pin 4 on the NETWORK LINK connector...

Страница 10: ...oft Windows 2000 Server Microsoft Windows 2000 Advanced Server Microsoft Windows 2000 Datacenter Server Microsoft Windows XP Home Edition Microsoft Windows XP Professional Microsoft Windows Server 200...

Страница 11: ...11 7 0 SOFTWARE INSTALLATION TM 3 Confirm Installation Click Next 4 If you accept the licence agreement check I Agree and Click Next 5 The programme will begin installing 6 Installation Complete...

Страница 12: ...ons Open Opens a file which contains parameters for the device A dialogue will appear inviting you to choose a file to open Save Saves the current settings If you have previously opened or saved a fil...

Страница 13: ...g synchronisation When a file is opened online the new settings are not only set in the control panel they are also transferred to the device Controlling Devices When online the tree menus will show t...

Страница 14: ...s Note that once the control is highlighted the PGUP PGDWN and Arrow keys or the mouse wheel may also be used to change the selection Spin boxes The value would normally be adjusted by clicking on the...

Страница 15: ...NTROL PANEL The control panel for VNET allows VNET parameters to be viewed and adjusted The panel is organised into a monitoring area at the top left of the panel where the status of VNET may be viewe...

Страница 16: ...n filters produce much steeper cut off slopes for a given order than conventional crossover alignments without any additional group delay This allows a lower order filter to be used without sacrificin...

Страница 17: ...en before this is done Data saved from one device can be reopened in another to save time inputting data Assuming settings are to be duplicated Podware will always try to protect your data warning you...

Страница 18: ...d is complete the following message appears The DSP is updating at this point Do not power down the unit or disconnect any network cable at this point During the update a red bar will show the progres...

Страница 19: ...e cured by equalisation Small alterations to loudspeaker positions can have the effect of minimising problematic combing frequencies Arrays should be constructed so that the individual coverage patter...

Страница 20: ...LATIONS AND COMPLIES WITH PART 15 OF THE FCC RULES OPERATION SUBJECT TO CONDITIONS STATED IN THE MANUAL WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOI...

Страница 21: ...EQUIPMENT REGULATIONS AND COMPLIES WITH PART 15 OF THE FCC RULES OPERATION SUBJECT TO CONDITIONS STATED IN THE MANUAL WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT...

Страница 22: ...22 12 0 PERFORMANCE DATA VNET12 Anechoic Frequency Response VNET12 HP Anechoic Frequency Response VNET300 Anechoic Frequency Response VNET15 Anechoic Frequency Response...

Страница 23: ...81 1 778 1 000 0 100 0 01 Full Power 2nd Harmonic 3rd Harmonic 2nd Harmonic 3rd Harmonic 2nd Harmonic 3rd Harmonic 2nd Harmonic 3rd Harmonic 250 Hz 0 100 0 141 0 11 0 71 0 316 0 447 0 126 0 032 1000 H...

Страница 24: ...685 x 900mm 263 16 x 175 16 x 175 16 22 x 217 8 x 259 16 2715 16 x 259 16 X 217 8 Weight 31kg 70lbs 44kg 98lbs 10oz 55kg 121lbs NOTES 1 Average over stated bandwidth Measured at 1 metre on axis 2 Unw...

Страница 25: ...fixed to a surface using a Tannoy Professional hardware device the installer must ensure that the surface is capable of safely and securely supporting the load The hardware employed must be safely se...

Страница 26: ...Fig 1 Fig 2 Number on Assembly View Fig 3 Description Quantity 1 Hanging Bracket 2 2 Cross Member 1 3 Pivot Stud 2 4 M10 Plain Washer 2 5 M8 Spring Washer 2 6 M10 Spring Washer 4 7 M10 x 30mm Screw 2...

Страница 27: ...27 TM 14 2 SECUR ET V15Y V12Y V15Y V12Y...

Страница 28: ...fixing obtained There are also two holes either side of the fixing beam to allow the speaker cable the pass through the wall plate and along the fixing beam to the terminal panel resulting in a more d...

Страница 29: ...to the desired angle Important It is imperative for safety reasons that two eyebolts linked to two independently fixed straps are used per cabinet VEB eyebolts should be installed into the relative si...

Страница 30: ...available in both black and white finishes and is to be used in conjunction with the VMY and a length of M10 threaded rod not supplied by Tannoy Limited The VCS ceiling saddle allows the Tannoy VNET...

Страница 31: ...HL 7900 0598 Driver Kit 3815 7900 0602 Recone Kit 3815 VNET18DR 7900 0599 Driver Kit 4505 7900 0603 Recone Kit 4505 VNET HARDWARE 8001 2780 VMY Secur ET Yoke Adjustable Black 8001 2790 VMY Secur ET Yo...

Страница 32: ...apparatus is are manufactured in UK by Tannoy Ltd of Rosehall Industrial Estate Coatbridge Scotland ML5 4TF The following equipment is marked with the CE label and conform s to the protection requirem...

Страница 33: ...TM 18 0 NOTES...

Страница 34: ...NOTES...

Страница 35: ...TM NOTES...

Страница 36: ...uct specification is subject to change Tannoy United Kingdom T 44 0 1236 420199 F 44 0 1236 428230 E enquiries tannoy com Tannoy North America T 519 745 1158 F 519 745 2364 E inquiries tannoyna com Ta...

Отзывы: