manualshive.com logo in svg
background image

C

M

Y

CM

MY

CY CMY

K

24

SYSTEM V

NET 15BP 

V

NET 15HL 

V

NET 18DR 

System Type

 Subwoofer - Band Pass 

Full Range — Horn Loaded

 Full Range — Direct Radiating

Frequency Response 

(1) +/- 3dB 

35Hz - 150Hz 

48Hz - 250Hz

27Hz - 200Hz

Maximum SPL

(2) 

Average 127dB

130dB 

130dB

Peak

133dB

136dB 136dB

Driver Complement 

1 x 380mm (15 ) 

1 x 380mm (15 ) 

1 x 458mm (18 )

Bass Unit 
Crossover (DSP Generated) 

Variable LPF 

Variable LPF 

Variable LPF

Distortion
0.1 Full Power

2nd Harmonic

3rd Harmonic

2nd Harmonic  

3rd Harmonic

2nd Harmonic

3rd Harmonic

50 Hz

0.22%  

0.71%

0.89%       

0.15%

0.25%  

0.19%                     

100 Hz

0.56%

0.31%

0.14% 

0.10%                   

0.20%             

0.15%

0.01 Full Power

2nd Harmonic  

3rd Harmonic

2nd Harmonic  

3rd Harmonic

2nd Harmonic  

3rd Harmonic

50 Hz

0.21%

0.31%

0.11%             

0.05% 

0.19%             

0.10%

100 Hz

0.25%

0.18%

0.79%             

0.09%

0.14%             

0.11%

CONSTRUCTION

Enclosure 

100 litre Bandpass

Horn Loaded 

202 litre Direct Radiating

15mm (

5

/

8

)  

18mm (

11

/

16

) 18mm 

(

11

/

16

)

multiple-ply birch plywood

multiple-ply birch plywood

multiple-ply birch plywood

Finish 

Textured Black or White paint (Custom colours on request).

Connectors 

1 x female XLR (input), 1 x RJ45 (network in), 1 male XLR (link), 1 x RJ45 (network link),

1 x Neutrik Powercon

Fittings 

2 x recessed carrying handle 2 x recessed carrying handle 4 x recessed carrying handle

Blanking plate for optional VTH pole mount

8 x M10 inserts for flying

4 x rubber feet

Dimensions 

665 x 440 x 440mm

578 x 555 x 650mm 

790 x 685 x 900mm

(26

3

/

16

 

x 17

5

/

16

 

x 17

5

/

16

(22  x 21

7

/

8

 x 25

9

/

16

)

(27

15

/

16

x 25

9

/

16

 X 

21

7

/

8

)

Weight 31kg (70lbs) 

44kg (98lbs 10oz) 

55kg (121lbs)

NOTES: (1) Average over stated bandwidth. Measured at 1 metre on axis.

(2) Unweighted pink noise input, measured at 1 metre in an anechoic chamber

A full range of measurements, performance data, and Ease“ Data can be downloaded from www.tannoy.com

Tannoy operates a policy of continuous research and development. The introduction of new materials or manufacturing methods will always equal or exceed the published specifications, which Tannoy reserves

the right to alter without prior

ELECTRONICS

 (Common to all models)

Efficiency

>85% typically

Damping Factor 

120 ref 8

Distortion

<0.05% @ 1kHz -3dB output

(22kHz bandwidth)

Input Impedance

5.6k  unbalanced, 11.2k  balanced

Output Power (Programme) 

VNET 12

VNET 12HP       VNET 15 

VNET 300        VNET15BP  

VNET15HL   VNET18DR

400W LF 

700W LF

800W LF   

500W LF

600W          

800W            1200W

400W HF

(limited)

 700W H

( limited)

 800W 

HF

(limited)

500W HF

(limited)

Input Sensitivity 

1.4V (+5.5dBu)

System Type 

Dual channel Class D

DSP system

 (Common to all models)

Comms Facilities

Firmware updatable and selected parameters editable

Communications 

Serial - RS485 Proprietary message format

Dynamic Range 

112dB(A) typical

DSP 

3rd generation SHARC

Sampling Frequency 

96kHz 24 bit A/D-D/A word length

Format 

1 IN - 2 OUT

PSU specifications

 (Common to all models)

Input Connector

Locking Neutrik Powercon

Voltage Selection 

Automatic (115 / 230V, 45 - 65Hz)

Switching Frequency 

192kHz Syncronised to DSP

13.0: TECHNICAL SPECIFICATIONS

Содержание VNET 12

Страница 1: ...Owners Manual VNET 12 VNET 12 HP VNET 15 VNET 300 VNET 15 HL VNET 15BP VNET 18DR TM...

Страница 2: ...nking cabinets 7 0 SOFTWARE INSTALLATION 8 0 SOFTWARE OPERATION 8 1 Updating firmware 9 0 EQUALISATION 10 0 ARRAYING 11 0 DIMENSIONS 12 0 PERFORMANCE DATA 13 0 TECHNICAL SPECIFICATIONS 14 0 RIGGING 14...

Страница 3: ...mally or has been dropped SAFETY WARNING Permanent disconnection from the mains supply is to be achieved by removing the supplied cord connector from the back of the unit SAFETY WARNING Do not remove...

Страница 4: ...emission compliance statement This Class B digital apparatus complies with Canadian ICES 003 Avis de conformite a la re glementation d Industrie Canada Cet appareil nume rique de classe A est conforme...

Страница 5: ...quired to configure the network nodes Each loudspeaker in the system can be individually optimized and acoustically profiled taking into account its exact position within the venue relative to the roo...

Страница 6: ...ch levels over 95dBspl for 8 hours per day can eventually cause permanent hearing loss Since Tannoy loudspeakers have a natural sounding flat frequency response and low distortion it s possible not to...

Страница 7: ...gth of time reduce the gain Fast regular flashing of the red LED indicates that the DSP is taking protective action the input will be automatically attenuated to avoid over driving if this occurs the...

Страница 8: ...manual extensive testing was carried out with the following devices Tannoy USB RS485 Converter Part No 8001 3920 K2 from KK www kksystems com USB COMi from Easysync www easysync co uk 485 SD9R from B...

Страница 9: ...Volts on the network Link connector that can be used to seamlessly power network extenders or repeaters that large networks may require This power can be located on pin 4 on the NETWORK LINK connector...

Страница 10: ...oft Windows 2000 Server Microsoft Windows 2000 Advanced Server Microsoft Windows 2000 Datacenter Server Microsoft Windows XP Home Edition Microsoft Windows XP Professional Microsoft Windows Server 200...

Страница 11: ...11 7 0 SOFTWARE INSTALLATION TM 3 Confirm Installation Click Next 4 If you accept the licence agreement check I Agree and Click Next 5 The programme will begin installing 6 Installation Complete...

Страница 12: ...ons Open Opens a file which contains parameters for the device A dialogue will appear inviting you to choose a file to open Save Saves the current settings If you have previously opened or saved a fil...

Страница 13: ...g synchronisation When a file is opened online the new settings are not only set in the control panel they are also transferred to the device Controlling Devices When online the tree menus will show t...

Страница 14: ...s Note that once the control is highlighted the PGUP PGDWN and Arrow keys or the mouse wheel may also be used to change the selection Spin boxes The value would normally be adjusted by clicking on the...

Страница 15: ...NTROL PANEL The control panel for VNET allows VNET parameters to be viewed and adjusted The panel is organised into a monitoring area at the top left of the panel where the status of VNET may be viewe...

Страница 16: ...n filters produce much steeper cut off slopes for a given order than conventional crossover alignments without any additional group delay This allows a lower order filter to be used without sacrificin...

Страница 17: ...en before this is done Data saved from one device can be reopened in another to save time inputting data Assuming settings are to be duplicated Podware will always try to protect your data warning you...

Страница 18: ...d is complete the following message appears The DSP is updating at this point Do not power down the unit or disconnect any network cable at this point During the update a red bar will show the progres...

Страница 19: ...e cured by equalisation Small alterations to loudspeaker positions can have the effect of minimising problematic combing frequencies Arrays should be constructed so that the individual coverage patter...

Страница 20: ...LATIONS AND COMPLIES WITH PART 15 OF THE FCC RULES OPERATION SUBJECT TO CONDITIONS STATED IN THE MANUAL WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOI...

Страница 21: ...EQUIPMENT REGULATIONS AND COMPLIES WITH PART 15 OF THE FCC RULES OPERATION SUBJECT TO CONDITIONS STATED IN THE MANUAL WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT...

Страница 22: ...22 12 0 PERFORMANCE DATA VNET12 Anechoic Frequency Response VNET12 HP Anechoic Frequency Response VNET300 Anechoic Frequency Response VNET15 Anechoic Frequency Response...

Страница 23: ...81 1 778 1 000 0 100 0 01 Full Power 2nd Harmonic 3rd Harmonic 2nd Harmonic 3rd Harmonic 2nd Harmonic 3rd Harmonic 2nd Harmonic 3rd Harmonic 250 Hz 0 100 0 141 0 11 0 71 0 316 0 447 0 126 0 032 1000 H...

Страница 24: ...685 x 900mm 263 16 x 175 16 x 175 16 22 x 217 8 x 259 16 2715 16 x 259 16 X 217 8 Weight 31kg 70lbs 44kg 98lbs 10oz 55kg 121lbs NOTES 1 Average over stated bandwidth Measured at 1 metre on axis 2 Unw...

Страница 25: ...fixed to a surface using a Tannoy Professional hardware device the installer must ensure that the surface is capable of safely and securely supporting the load The hardware employed must be safely se...

Страница 26: ...Fig 1 Fig 2 Number on Assembly View Fig 3 Description Quantity 1 Hanging Bracket 2 2 Cross Member 1 3 Pivot Stud 2 4 M10 Plain Washer 2 5 M8 Spring Washer 2 6 M10 Spring Washer 4 7 M10 x 30mm Screw 2...

Страница 27: ...27 TM 14 2 SECUR ET V15Y V12Y V15Y V12Y...

Страница 28: ...fixing obtained There are also two holes either side of the fixing beam to allow the speaker cable the pass through the wall plate and along the fixing beam to the terminal panel resulting in a more d...

Страница 29: ...to the desired angle Important It is imperative for safety reasons that two eyebolts linked to two independently fixed straps are used per cabinet VEB eyebolts should be installed into the relative si...

Страница 30: ...available in both black and white finishes and is to be used in conjunction with the VMY and a length of M10 threaded rod not supplied by Tannoy Limited The VCS ceiling saddle allows the Tannoy VNET...

Страница 31: ...HL 7900 0598 Driver Kit 3815 7900 0602 Recone Kit 3815 VNET18DR 7900 0599 Driver Kit 4505 7900 0603 Recone Kit 4505 VNET HARDWARE 8001 2780 VMY Secur ET Yoke Adjustable Black 8001 2790 VMY Secur ET Yo...

Страница 32: ...apparatus is are manufactured in UK by Tannoy Ltd of Rosehall Industrial Estate Coatbridge Scotland ML5 4TF The following equipment is marked with the CE label and conform s to the protection requirem...

Страница 33: ...TM 18 0 NOTES...

Страница 34: ...NOTES...

Страница 35: ...TM NOTES...

Страница 36: ...uct specification is subject to change Tannoy United Kingdom T 44 0 1236 420199 F 44 0 1236 428230 E enquiries tannoy com Tannoy North America T 519 745 1158 F 519 745 2364 E inquiries tannoyna com Ta...

Отзывы: