manualshive.com logo in svg
background image

C

M

Y

CM

MY

CY CMY

K

TM

3

1.0: IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS

1

Read these instructions.

2

Keep these instructions.

3

Heed all warnings.

4

Follow all instructions.

5

Do not use this apparatus near water.

6

Clean only with dry cloth.

7

Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.

8

Do not install near any heat sources such as radiators, heat registers, stoves or other apparatus (including amplifiers)
that produce heat.

9

Do not defeat the safety purpose of the polarized or grounding type plug. A polarized plug has two blades with one 
wider than the other. A grounding type plug had two blades and a third grounding prong. The wide blade or the third
prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement
of the obsolete outlet.

10

Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles and the point
where they exit from the apparatus.

11

Only use attachments / accessories specified by the manufacturer.

12

Use only with the cart, tripod, bracket or table specified by the manufacturer, or sold with the apparatus. When a cart
is used, use caution when moving the cart / apparatus combination to avoid injury from tip-over.

13

Unplug this apparatus during lightening storms or when unused for long periods of time.

14

Refer all servicing to qualified service personnel. Service is required when the apparatus has been damaged in any
way, such as power-supply cord or plug damaged, liquid has been spilled or objects have fallen into the apparatus, 
this apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

SAFETY WARNING

Permanent disconnection from the mains supply is to be achieved by removing the supplied cord connector from the back of
the unit.

SAFETY WARNING

Do not remove any covers, loosen any fixings or allow items to enter any aperture.

SAFETY WARNING

Objects filled with liquids should not be placed on this apparatus.

SAFETY WARNING

Replace the mains fuse only with the same T10A HBC type supplied by Tannoy under part number 34610919

SAFETY WARNING

The rear heatsink on this product gets hot. Avoid direct skin contact during operation and for at least 5 minutes after power
has been isolated.

AVERTISSEMENT DE SECURITE

Pour d connecter l’appareil de l’alimentation principale de fa on permanente, d branchez le connecteur du c ble fourni 
l’arri re de l’appareil.

AVERTISSEMENT DE SECURITE

Ne retirez pas les couvercles, ne desserrez pas les fixations et ne laissez aucune pi ce s’introduire dans les ouvertures.

AVERTISSEMENT DE SECURITE

Ne placez pas d’objets contenant du liquide   proximit  de l’appareil.

AVERTISSEMENT DE SECURITE

Ne remplacez le fusible de r seau principal que par un fusible T10A HBC du m me type fourni par Tannoy sous la r f rence
34610919.

AVERTISSEMENT DE SECURITE

Le radiateur arri re de cet appareil devient chaud. Evitez tout contact direct avec la peau pendant le fonctionnement et au
moins 5˚minutes apr s la mise hors tension de l’appareil.

The lightning flash with an arrowhead symbol within an
equilateral triangle, is intended to alert the user to the
presence of uninsulated  dangerous voltage  within the
product s enclosure that may be of sufficient magnitude
to constitute a risk of electric shock to persons.

The exclamation point within an equilateral triangle is
intended to alert the user to the presence of important
operating and maintenance (servicing) instructions in the
literature accompanying the product.

Содержание VNET 12

Страница 1: ...Owners Manual VNET 12 VNET 12 HP VNET 15 VNET 300 VNET 15 HL VNET 15BP VNET 18DR TM...

Страница 2: ...nking cabinets 7 0 SOFTWARE INSTALLATION 8 0 SOFTWARE OPERATION 8 1 Updating firmware 9 0 EQUALISATION 10 0 ARRAYING 11 0 DIMENSIONS 12 0 PERFORMANCE DATA 13 0 TECHNICAL SPECIFICATIONS 14 0 RIGGING 14...

Страница 3: ...mally or has been dropped SAFETY WARNING Permanent disconnection from the mains supply is to be achieved by removing the supplied cord connector from the back of the unit SAFETY WARNING Do not remove...

Страница 4: ...emission compliance statement This Class B digital apparatus complies with Canadian ICES 003 Avis de conformite a la re glementation d Industrie Canada Cet appareil nume rique de classe A est conforme...

Страница 5: ...quired to configure the network nodes Each loudspeaker in the system can be individually optimized and acoustically profiled taking into account its exact position within the venue relative to the roo...

Страница 6: ...ch levels over 95dBspl for 8 hours per day can eventually cause permanent hearing loss Since Tannoy loudspeakers have a natural sounding flat frequency response and low distortion it s possible not to...

Страница 7: ...gth of time reduce the gain Fast regular flashing of the red LED indicates that the DSP is taking protective action the input will be automatically attenuated to avoid over driving if this occurs the...

Страница 8: ...manual extensive testing was carried out with the following devices Tannoy USB RS485 Converter Part No 8001 3920 K2 from KK www kksystems com USB COMi from Easysync www easysync co uk 485 SD9R from B...

Страница 9: ...Volts on the network Link connector that can be used to seamlessly power network extenders or repeaters that large networks may require This power can be located on pin 4 on the NETWORK LINK connector...

Страница 10: ...oft Windows 2000 Server Microsoft Windows 2000 Advanced Server Microsoft Windows 2000 Datacenter Server Microsoft Windows XP Home Edition Microsoft Windows XP Professional Microsoft Windows Server 200...

Страница 11: ...11 7 0 SOFTWARE INSTALLATION TM 3 Confirm Installation Click Next 4 If you accept the licence agreement check I Agree and Click Next 5 The programme will begin installing 6 Installation Complete...

Страница 12: ...ons Open Opens a file which contains parameters for the device A dialogue will appear inviting you to choose a file to open Save Saves the current settings If you have previously opened or saved a fil...

Страница 13: ...g synchronisation When a file is opened online the new settings are not only set in the control panel they are also transferred to the device Controlling Devices When online the tree menus will show t...

Страница 14: ...s Note that once the control is highlighted the PGUP PGDWN and Arrow keys or the mouse wheel may also be used to change the selection Spin boxes The value would normally be adjusted by clicking on the...

Страница 15: ...NTROL PANEL The control panel for VNET allows VNET parameters to be viewed and adjusted The panel is organised into a monitoring area at the top left of the panel where the status of VNET may be viewe...

Страница 16: ...n filters produce much steeper cut off slopes for a given order than conventional crossover alignments without any additional group delay This allows a lower order filter to be used without sacrificin...

Страница 17: ...en before this is done Data saved from one device can be reopened in another to save time inputting data Assuming settings are to be duplicated Podware will always try to protect your data warning you...

Страница 18: ...d is complete the following message appears The DSP is updating at this point Do not power down the unit or disconnect any network cable at this point During the update a red bar will show the progres...

Страница 19: ...e cured by equalisation Small alterations to loudspeaker positions can have the effect of minimising problematic combing frequencies Arrays should be constructed so that the individual coverage patter...

Страница 20: ...LATIONS AND COMPLIES WITH PART 15 OF THE FCC RULES OPERATION SUBJECT TO CONDITIONS STATED IN THE MANUAL WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOI...

Страница 21: ...EQUIPMENT REGULATIONS AND COMPLIES WITH PART 15 OF THE FCC RULES OPERATION SUBJECT TO CONDITIONS STATED IN THE MANUAL WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT...

Страница 22: ...22 12 0 PERFORMANCE DATA VNET12 Anechoic Frequency Response VNET12 HP Anechoic Frequency Response VNET300 Anechoic Frequency Response VNET15 Anechoic Frequency Response...

Страница 23: ...81 1 778 1 000 0 100 0 01 Full Power 2nd Harmonic 3rd Harmonic 2nd Harmonic 3rd Harmonic 2nd Harmonic 3rd Harmonic 2nd Harmonic 3rd Harmonic 250 Hz 0 100 0 141 0 11 0 71 0 316 0 447 0 126 0 032 1000 H...

Страница 24: ...685 x 900mm 263 16 x 175 16 x 175 16 22 x 217 8 x 259 16 2715 16 x 259 16 X 217 8 Weight 31kg 70lbs 44kg 98lbs 10oz 55kg 121lbs NOTES 1 Average over stated bandwidth Measured at 1 metre on axis 2 Unw...

Страница 25: ...fixed to a surface using a Tannoy Professional hardware device the installer must ensure that the surface is capable of safely and securely supporting the load The hardware employed must be safely se...

Страница 26: ...Fig 1 Fig 2 Number on Assembly View Fig 3 Description Quantity 1 Hanging Bracket 2 2 Cross Member 1 3 Pivot Stud 2 4 M10 Plain Washer 2 5 M8 Spring Washer 2 6 M10 Spring Washer 4 7 M10 x 30mm Screw 2...

Страница 27: ...27 TM 14 2 SECUR ET V15Y V12Y V15Y V12Y...

Страница 28: ...fixing obtained There are also two holes either side of the fixing beam to allow the speaker cable the pass through the wall plate and along the fixing beam to the terminal panel resulting in a more d...

Страница 29: ...to the desired angle Important It is imperative for safety reasons that two eyebolts linked to two independently fixed straps are used per cabinet VEB eyebolts should be installed into the relative si...

Страница 30: ...available in both black and white finishes and is to be used in conjunction with the VMY and a length of M10 threaded rod not supplied by Tannoy Limited The VCS ceiling saddle allows the Tannoy VNET...

Страница 31: ...HL 7900 0598 Driver Kit 3815 7900 0602 Recone Kit 3815 VNET18DR 7900 0599 Driver Kit 4505 7900 0603 Recone Kit 4505 VNET HARDWARE 8001 2780 VMY Secur ET Yoke Adjustable Black 8001 2790 VMY Secur ET Yo...

Страница 32: ...apparatus is are manufactured in UK by Tannoy Ltd of Rosehall Industrial Estate Coatbridge Scotland ML5 4TF The following equipment is marked with the CE label and conform s to the protection requirem...

Страница 33: ...TM 18 0 NOTES...

Страница 34: ...NOTES...

Страница 35: ...TM NOTES...

Страница 36: ...uct specification is subject to change Tannoy United Kingdom T 44 0 1236 420199 F 44 0 1236 428230 E enquiries tannoy com Tannoy North America T 519 745 1158 F 519 745 2364 E inquiries tannoyna com Ta...

Отзывы: