background image

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

WARNING: SHOCK HAZARD, DO NOT OPEN.

AVIS: RIAQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.

CUIDADO: PELIGRO DE CHOQUE ELÉCTRICO - NO ABRIR

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK 

DO NOT REMOVE COVER (OR BACK)

NO USER SERVICEABLE PARTS INSIDE

REFER SERVICING TO QUALIFIED PERSONNEL

THIS                 PRODUCT IS DESIGNED FOR 120-VOLT USE

ONLY!  FOR DETAILED SAFETY PRECAUTIONS, PLEASE SEE

FOLLOWING PAGE IN THIS OWNER’S MANUAL FOR 

“IMPORTANT SAFETY INSTRUCTION”.

The lightening flash with arrowhead symbol, within an equilateral triangle,
is intended to alert the user to the presence of uninsulated “dangerous
voltage” within the product’s enclusure that may be of sufficient magnitude
to constitue a risk of electrical shock to persons.

The exclamation point within an equilateral triangle is intended to alert the
user to the presence of important operating and maintenance (servicing)
instructions in the literature accompanying the product.

L’éclair avec le symbole de la fléche, placé dans les limites d’un triangel
équilatéral est prévu pour avertír l’utilisateur de la présence de "lension
dangereuse" non isolée dans l’enceinte du produit qui pourrait érre d’une
importance suflisante pour présenter un risque d’électrocution aux personnes.

La point d’exclamation dans un triangel équilateral est prévu pour avertir
l’utilisateur de la présence d’instructions importantes pour les opérations
et l’entretien (service) dans les manuels fournis avec l’appareil.

ATTENTION: POUR EVITER LES CHOCS ELECTRIQUES, INTRODUIRE LA

LAME LA PLUS LARGE DE LA FICHE DANS LA BORNE CORRESPON-

DANTE DE LA PRISE ET POUSSER JUSQUAU FOND.

“WARNING: SHOCK HAZARD - DO NOT OPEN.  AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR” or
equivalent, together with the two graphical symbols - a lightning flash with arrow-point withing an equilateral triangle, an
exclamation point within an equilateral triangle, appears on the removable cover to gain access.

“CAUTION: TO PREVENT ELECTRICAL SHOCK, MATCH WIDE BLADE OF PLUG TO WIDE SLOT, FULLY INSERT” and
ATTENTION: POUR ÉVITER LES CHOCS ÉLECTRIQUES, INTRODUIRE LA LAME LA PLUS LARGE DE LA FICHE DANS
LA BORNE CORRESPONDANTE DE LA PRISE ET POUSSER JUSQU’AU FOND” or equivalent on a label attached on the
line cord, or the owner’s manual.

!

!

Содержание PS350

Страница 1: ...ll F ree Dealer F axline 800 525 7081 e ma il inquirie s ta nnoyna c om w w w ta n n o y c o m Feature Alert You have purchased a unique subwoofer featuring True B as s Management This is a special feature of the PS 350B that you need to be familiar with before installation It is vital that you read and understand this Operator Manual and the available options before proceeding N O R T H A M E R I...

Страница 2: ...on 4 Descriptions of Features Section 5 Placement of the Subwoofer Section 6 Installation Section 7 Applications Section 8 System Protection Section 9 Care of the Subwoofer Section 1 0 Troubleshooting Section 1 1 Product Specifications Section 1 2 Warranty Table of Contents N O R T H A M E R I C A I N C ...

Страница 3: ...g as soon as possible However a little time dedicated to reading and understanding this manual now will save you time in the long run and ensure that you obtain the best possible performance from your new subwoofer Section 2 What is True Bass Management PS350B only Into today s demanding world of audio small high quality studio nearfields and satellite speakers have become very popular Of course i...

Страница 4: ...NG CONDITIONS 1 THIS DE VICE DOE S NOT CAUS E HAR MFUL INTE R FE R E NCE AND 2 THIS DE VICE MUS T ACCE PT ANY INTE R FE R E NCE R E CE IVE D INCLUDING INTE R FE R E NCE THAT MAY CAUS E UNDE S IR E D OPE R ATION 150Hz 120Hz 100Hz 80Hz R IS K OF E LE CTR IC S HOCK DO NOT OPE N CAUTION R IS QUE DE CHOCS E LE CTR IQUE NE PAS OUVR IR ATTE NTION LR 106476 ANS I UL 1492 NRTL C A B C D E F G H I J K L M P...

Страница 5: ...nd of the cable you will be deactivating the Bass Management When deactivating the Bass Management two operations are occurring simultaneously One the LCR 80 Hz High Pass filters are by passed making the outputs full frequency Two the LCR signal is removed from the subwoofer signal path The only signal present at the subwoofer will be from the LFE input By depress ing the switch again you will rea...

Страница 6: ...nd axial but this also changes the loading on the subwoofer which lifts the bass frequencies up in level Placing the woofer in a corner two walls and a floor gives you another 3 dB more low frequency energy than the two boundary condi tion for a total of 6 dB over the unit in the middle of the floor When setting things up the first time you will need to adjust the subwoofer level for various room ...

Страница 7: ...e crossover a good starting point is to between 80 Hz and 100 Hz 2 Phase set to O deg Note Refer to Phase Switch 4 M for further details 3 Bass boost set to Min Note Refer to LFE Boost 4 K for further details 4 Set the Sub Level control on the PS350 PS350B to Min initially LFE R R R F C LR LF C enter L C R LFE In R ight R ear R ight Front R eceiver Left Front Left R ear In Out 1 S ub 2 S ubs PS350...

Страница 8: ...ails 3 Bass boost set to Min Note Refer to LFE Boost 4 K for further details 4 Set the Sub Level on the PS350B to Min initially PS350B Five Channel Amp Left Front Left R ear R ight Front Center R ight R ear Preamp In Out LF LR C R F R R LFE In R C L In Out LF LR C R F R R LFE 1 Sub 2 Subs figure 2 d Two PS350 350B with preamp and 5 channel amp no bass management 1 Using a Y cable connect the pream...

Страница 9: ... LF LR C R F R R Five Channel Amp R ight R ear R ight Front Left Front Left R ear C enter figure 5 f Stereo setup with one PS350 PS350B utilizing internal filtering 1 Connect a cable from the signal source left output to the PS350 PS350B Left input Connect the Left subwoofer out put to the power amplifier left input Repeat for the right channel 2 Phase set to 0 deg Note Refer to Phase Switch 4 M f...

Страница 10: ...a qualified electrician B If the AC outlet is live and the amplifier is still not pow ered double check that the power switch is in the ON position C If the unit is still not powered up unplug the unit Remove and test the fuse on the rear control panel with a continuity tester If blown replace with a new fuse of the same specified value D If the unit still refuses to power up contact your dealer o...

Страница 11: ...dB 29 Hz 6th order tuning vented box 36 dB Octave below 31 Hz Amplifier type ProBASH technology featuring High Efficiency Linear Amplifier circuit topology Power rating 350 Watts instantaneous peak limiter threshold Protection Threshold at onset of clipping Power indicator Front mounted LED is greed in active mode when signal is present or on initial power up The green LED turns to red if signal i...

Страница 12: ...iangel équilatéral est prévu pour avertír l utilisateur de la présence de lension dangereuse non isolée dans l enceinte du produit qui pourrait érre d une importance suflisante pour présenter un risque d électrocution aux personnes La point d exclamation dans un triangel équilateral est prévu pour avertir l utilisateur de la présence d instructions importantes pour les opérations et l entretien se...

Отзывы: