background image

Should you encounter any problems obtaining Speakon connectors, please contact
Neutrik or its distributors directly on the following numbers:-

UK: N

EUTRIK 

M

ARKETING:

0171 792 8188

USA: N

EUTRIK 

USA I

NC.:

(201) 901 9488

For a world wide list of distributors, please contact Neutrik directly:-

N

EUTRIK

 AG:

+41 7529666

Cable choice consists mainly of selecting the correct cross sectional area in relation
to the cable length and the load impedance. A small cross sectional area would
increase the cables series resistance, inducing power loss and response variations
(damping factor).

Connectors should be wired with a minimum of 2.5 sq. mm (12 gauge) cable. This
will be perfectly satisfactory under normal conditions. In the case of very long cable
runs the wire size should exceed this, refer to the following table for guidance:-

CABLE RUN
(m)

C.S.A. OF EACH
CONDUCTOR (mm)

CABLE
RESISTANCE 

% POWER LOSS
INTO 8

 LOAD

% POWER LOSS
INTO 4

 LOAD

10

2.5
4.0
6.0

0.14
0.09
0.06

1.7
1.1
0.73

3.5
2.2
1.5

25

2.5
4.0
6.0

0.35
0.22
0.14

4.3
2.7
1.8

8.6
5.4
3.6

50

2.5
4.0
6.0

0.69
0.43
0.29

8.6
5.4
3.6

17.0
11.0
7.2

100

2.5
4.0
6.0

1.38
0.86
0.58

17.0
11.0
7.2

35.0
22.0
14.0

4. 

 Polarity Checking

It is most important to check the polarity of the wiring before the speaker system is
used. A simple method of doing this without a pulse based polarity checker for LF
units is as follows: Connect two wires to the +ve and -ve terminals of a PP3 battery.
Apply the wire which is connected to the +ve terminal of the battery to the speaker
cable leg which you believe to be connected to pin 1+ of the speaker connector and
likewise the -ve leg of the battery to pin 1-.

If you have wired it correctly the LF drive unit will move forward, indicating the wiring
is correct. All that remains now is to connect the +ve speaker lead to the +ve
terminal on the amplifier and the -ve lead to the -ve terminal on the amplifier. If
however the LF driver moves backwards, the input connections need to be inverted.

If problems are encountered, inspect the cable wiring in the first instance. It should
also be noted that different amplifier manufacturers utilise different pin configurations
and polarity conventions, if you are using amplifiers from more than one
manufacturer, check the polarity at the amplifiers as well as the loudspeakers.

Содержание i15

Страница 1: ...i15 USER MANUAL ...

Страница 2: ...hecking 5 Amplification Power Handling 6 Crossovers 7 Equalisation 8 Dimensions 9 Rigging 10 Performance Data 11 Technical Specifications 12 i15 Recommended Service Parts Accessories 13 Warranty 14 Wall Mounting Bracket Assembly Instructions 15 Declaration of Conformity ...

Страница 3: ...e enclosure is further enhanced by internal steel braces which double as the flying points accepting M8 eyebolts strategically placed to distribute the weight of the enclosure evenly For applications requiring extended low frequency enhancement a range of Tannoy sub bass systems are available and can be used in conjunction with the i15 2 Unpacking Every Tannoy i15 is carefully inspected before pac...

Страница 4: ...0 6 0 0 69 0 43 0 29 8 6 5 4 3 6 17 0 11 0 7 2 100 2 5 4 0 6 0 1 38 0 86 0 58 17 0 11 0 7 2 35 0 22 0 14 0 4 Polarity Checking It is most important to check the polarity of the wiring before the speaker system is used A simple method of doing this without a pulse based polarity checker for LF units is as follows Connect two wires to the ve and ve terminals of a PP3 battery Apply the wire which is ...

Страница 5: ...ormance of the loudspeaker to be realised It is important when using different manufacturers amplifiers in a single installation that they have very closely matched gains the variation should be less than 0 5dB This precaution is important to the overall system balance when only a single active crossover is being used with multiple cabinets it is therefore recommended that the same amplifiers are ...

Страница 6: ...8 Dimensions ...

Страница 7: ...9 Rigging ...

Страница 8: ...10 Performance Data ...

Страница 9: ...Complement 1 x 15 381mm Constant Directivity Dual Concentric Type number 3804 Crossover Point Passive 1 6kHz 3 rd order high pass 2 nd order low pass Halogen HF protection Enclosure 65 litre vented MDF Finish Textured black grey paint Connectors 2 x Speakon NL4MPR IN OUT Fittings 8 x M8 flying inserts 1 x M8 pullback point Dimensions 590mm H x 450mm W x 420mm D 23 2ins H x 17 71ins W x 16 54ins D ...

Страница 10: ... only be carried out by a Tannoy Professional dealer or service agent This warranty in no way affects your statutory rights For further information please contact your dealer or distributor in your country If you cannot locate your distributor please contact Customer Services Tannoy Ltd at the address given below Customer Services Tannoy Ltd Rosehall Industrial Estate Coatbridge Strathclyde ML5 4T...

Страница 11: ...ng the two cap head bolts which are included along with the bracket hardware remembering to use the washers and locking washers which are also provided Assemble the bracket as shown on the diagram below It is imperative that the bracket is fixed soundly to the wall Be sure to use the correct fixings e g Rawbolt Rawplug according to the wall type Portrait mounting Using a hacksaw cut along the inde...

Страница 12: ...ic disturbance to enable operation as specified and intended Details of the Apparatus Tannoy Contractor Loudspeaker Model Number i15 Associated Technical File EMCi15 Applicable Standards EN 50081 1 Emission EN 50082 1 Immunity Signed Position Technical Manager Tannoy Professional Date 16th July 1998 For Tannoy Ltd Tannoy Loudspeakers are manufactured in Great Britain by Tannoy Ltd Rosehall Industr...

Отзывы: