Attach Control Box Assembly to Scale

1. Find the control panel box, transformer bracket, 

C-clamp and 4 locknuts.

2. Attach the control panel box to the center handlebar

rail using the C-clamp. Also mount the transformer
bracket on two of the studs extending through the 
C-clamp. Secure the control panel box with the 
(4) locknuts.

3. Attach the cable lead to the 5-prong jack (63932) 

on the side of the control panel box. Secure by turning
the knurled ring. Clip cable to the left handlebar with
clips supplied.

Leveling the Platform

To level or adjust the height of the scale platform,
carefully tilt the scale back on the handlebar and turn the
leveling feet either into or out of the platform underside.

NOTE:

Adjust platform height so that bottom edge of

platform or wheels do not touch floor or carpet. An
incorrect reading will result if the platform touches the
floor or carpet.

BATTERY CHARGING

The rechargeable battery in this scale is similar to the 
no-maintenance lead-acid batteries used in automobiles.
Since the battery is sealed, no checking of water level 
or adding of water to the battery is necessary. However,
recharging at proper intervals and proper storage
procedures are necessary, similar to an automobile
battery. A fully charged battery will provide approximately
250 normal weighings before requiring recharging.
When the display flashes “Lo-b,” the battery needs to 
be recharged.

Charging the Battery

A. Plug the battery charger power cord into the 3-prong

jack on control panel box. Secure by turning the
knurled ring.

B. Plug the battery charger into a 120 VAC outlet.

C. The battery will fully charge in 8 hours. THE SCALE

MAY BE USED WHILE THE BATTERY IS CHARGING.

NOTE:

The specially designed charger built into this scale

prevents the battery from being overcharged. Use of a
charger or adapter other than the one designed for this
scale can result in SERIOUS DAMAGE TO THE SCALE
OR BATTERY.

Optimum battery life will be obtained if the scale is
operated and stored connected to 120 VAC. Always check
the plug to see if the scale is charging before moving.

STORAGE:

When storing the scale for an extended

period of time (and the unit is not connected to a 120
VAC), the battery should be fully charged. The battery
should then be charged every three months. A
discharged battery should be recharged as soon as
possible to prevent its useful life from decreasing
significantly. A discharged battery left in the scale can
leak and cause permanent damage to the battery and
scale. Store the unit in a cool, dry place.

PRODUCT DESCRIPTION

Control Panel Box 

The scale control panel keypad has four membrane
switches. The POUNDS, KILOS, and ZERO switches 
have both primary and secondary functions listed below.
Only the primary functions are listed on the switch.

3

Keypad

63911

Control Box

Clamp 63935

AC Adapter

Bracker 63925

ZERO

POUNDS

KILOS

ON

OFF

Pounds Kilos

www.tanita.com

Push “ON” button

and wait until zero

appears before

stepping on scale

WEIGHT

Содержание 3500

Страница 1: ...Instructions 2 Before Assembly Assembling the Scale Attach Control Panel Box Leveling Platform Battery Charging 3 Charging the Battery Product Description 3 Control Panel Box Special Features Specifications Operating Instructions 4 Using the Zero Function Taking a Weight Measurement Care and Maintenance 5 Cleaning Calibration Troubleshooting Guide 5 Parts Lists 6 Warranty 7 OPERATOR S MANUAL ...

Страница 2: ...ientation of new personnel Use only the appropriate connecting cable designed specifically for use with this monitor If the cabling provided with this unit becomes cracked or damaged it should be repaired or replaced immediately If the scale becomes damaged it should not be operated until properly serviced All repairs should only be performed by authorized Tanita Corporation service personnel Scal...

Страница 3: ...read the control cable with connector through the right handlebar mounting hole in the wheel cover Insert the cable into the keyway in the mounting hole Fig 1 4 Lay the platform down Insert the handlebar into the 2 two mounting holes in the wheel cover Make sure the control cable is seated in the mounting hole keyway Fig 2 5 Line up the holes in the handlebar with the holes in the wheel cover Secu...

Страница 4: ...o be recharged Charging the Battery A Plug the battery charger power cord into the 3 prong jack on control panel box Secure by turning the knurled ring B Plug the battery charger into a 120 VAC outlet C The battery will fully charge in 8 hours THE SCALE MAY BE USED WHILE THE BATTERY IS CHARGING NOTE The specially designed charger built into this scale prevents the battery from being overcharged Us...

Страница 5: ...12 5 lb 5 6 kg OPERATING INSTRUCTIONS Using the Zero Function When using the Stand on Scale the weight of any object accompanying the patient blanket etc must be taken into account during a weighing Weigh the object s by themselves to determine their weight and subtract this weight from the combined weight of patient and object s METHOD 1 1 Scale is off 2 Place the object blanket etc on the scale ...

Страница 6: ...eatable reading In this case a series of moving dashes continues to appear on the console rather than a weight reading If moving dashes persist activate the Average Lock by depressing the appropriate Pounds or Kilos switch to obtain an average reading of the patient s weight Note This reading is now an instantaneous average of weights that the computer calculates 5 After weight is obtained and rec...

Страница 7: ...1 3 CAP ELE 470UF 25V C1 C7 C12 1 CERAMIC RES 4 00MHz X1 4 TRANS PNP PWR 2N6728 Q1 Q2 Q3 Q4 2 TRANS PNP PWR TIP32 Q5 Q7 1 TRANS PNP GEN MPS3702 Q8 13 TRANS NPNGEN MPS3704 Q6 Q9 Q10 Q11 Q12 Q13 Q14 Q15 Q16 Q17 Q18 Q19 Q2 4 DIODE SIGNAL 1N4148 CR1 CR7 CR14 CR15 1 DIODE ZENER 9 1V 1N4739A CR2 10 DIODE REC 600V 1N4005 CR3 CR4 CR5 CR6 CR8 CR9 CR10 CR11 CR12 CR13 2 IC REG 5V 7805 U1 U2 1 IC MICROPROCESS...

Страница 8: ... by the breach of an express or implied warranty or condition Except to the extent prohibited by applicable law any implied warranty of merchantability or fitness for a particular purpose is limited in duration to the duration of the above warranty Tanita disclaims all other warranties or conditions express or implied statutory or otherwise Some provinces or jurisdictions do not allow the exclusio...