Instruction S-1200:
1. Turn off water supply and drain lines. Hand tighten
no.
9
firmly against no.
1
and remove no.
10
from no.
4
.
2. Drill 7/8” hole in sheet metal. Insert no.
1
through hole
and screw no.
10
on back of no.
1
, leaving no.
9
free to
turn.
3. Apply teflon tape or pipe joint compound to threads
of water supply line. Connect no.
1
to water supply line
outlet, tightening as far as possible.
4. Tighten no.
9
and no.
10
so they are flush against sur-
face of sink back.
5. Turn on water supply and check for leaks.
Flow Adjustment:
To adjust water flow, use included T-45 Torx wrench & inserting it into no.16 turn clockwise to
increase water flow, turn counterclockwise to reduce water flow.
9
4
10
sink back
1
16
Installation S-1210:
1. Turn off water supply and drain lines.
2. Unscrew and remove no.
12
and no.
13
from no.
5
.
Position no.
11
to cover threads of no.
5
.
3. Place no.
5
through 7/8” hole in countertop. Replace
no.
12
and no.
13
onto no.
5
and tighten with a wrench
at bottom side of countertop.
4. Apply teflon tape or pipe joint compound to threads
of no.
5
, connect to water supply line inlet.
5. Turn on water supply and check for leaks.
To adjust water flow see flow adjustment note for
S-1200 model.
5
11
13
12
1
16