14
2.3
Rear Panel Layout
Figure 2.2 KV5-100 mk3 rear panel
2.2.2
Rear Panel Control Functions
A
Output fuse
Fuse for output voltage
B
Interlock socket
For connection to an external interlock system
C
Main power input
Selects mA meter range
D
Input fuse/Voltage selector
Mains input fuse and selects mains input
voltage (see 2.1.1.3.1)
E
Earth Terminal
For connection to a low impedance local earth
2.4
Method of Operation
2.4.1
Connections
WARNING
Before making any connections please ensure that you are aware of all
hazards relating to the system and environment in which it is operating.
Ensure that the key switch is in the off position and the key is removed
before making any connections. The test object must be earthed before
making or breaking any connections after testing.
Ensure that the key switch is in the off position and the key is removed before making
connections to the object under test or connecting the unit to the mains supply.
Connect the mains input lead to a suitable three pin supply outlet.