Safety Precautions and Instructions

To ensure safety obey all of the following warnings

The following items should be strictly obeyed for the safe usage of this unit, 

and  for  protecting  yourself  and  other  people  from  bodily  harm  and/or 

damage  to  property.  Before  using  make  sure  to  carefully  read,  understand 

and  follow  the  safety  rules  and  precautions  for  our  products  as  outlined 

below.

Explanation of Symbols

Explanation of Warning Symbols

 

WARNING

These entries are actions that absolutely under no circumstance should 
be taken. The taking of such an action may cause serious personal 
physical damage or death.

 

CAUTION

These entries are actions that if taken may lead to physical injury or 
damage to persons or things.

Explanation of Picture Symbols

Denotes an important warning or caution. Inside or near the symbol 

may appear another symbol giving details.

( EX: 

 Be careful of electrocution)

Denotes a forbidden action. Inside or near the symbol may appear 

another symbol giving details.

 ( EX: 

 Do not use in wet areas.)

Denotes an action that you must take. Inside or near the symbol may 

appear another symbol giving details. 

( EX: 

 Unplug power plug from outlet)

Содержание TR-73U

Страница 1: ...User s Manual Thank you for purchasing our product Carefully read this instruction manual before using this unit Copyright T D Corporation All rights reserved 2015 09 16504480007 7th Edition TR 73U...

Страница 2: ......

Страница 3: ...owners Specifications design and other contents outlined in this manual are subject to change without notice Please follow the safety precautions outlined in this manual carefully We cannot guarantee...

Страница 4: ...of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and ca...

Страница 5: ...unctions 10 Package Contents 12 Before Using 13 Part Names and Functions 14 Part Names and Functions 14 LCD Display 15 Installing the Battery 16 Turning ON the Power 17 Connecting the Sensors 18 Conne...

Страница 6: ...ns that absolutely under no circumstance should be taken The taking of such an action may cause serious personal physical damage or death CAUTION These entries are actions that if taken may lead to ph...

Страница 7: ...not use this unit in wet or humid places such as a bathroom It may cause a fire or other trouble including malfunction Store main units sensors batteries and communication cables out of the reach of...

Страница 8: ...tricity remove static electricity from your body by touching metal aroung you door knob window frame before touching the unit Static electricity may cause not only damage to the unit but may cause bre...

Страница 9: ...her damage including malfunction Areas prone to strong magnetic fields This may cause damage including malfunction Areas exposed to water leakage This may cause electrocution or other damage incluing...

Страница 10: ...the sensor within these ranges If extremely severe temperature changes occur the humidity measurements may appear abnormal Once the sensor s temperature becomes stable the measurements will return to...

Страница 11: ...5 to 25 C and a humidity of below 30 RH Attached to the temperature humidity sensor are two stickers a wetness detection sticker and a temperature detection sticker If either of the stickers shows abn...

Страница 12: ...ure sensor can measure and record in a range of 10 to 60 C but by purchasing one of our optional temperature sensors it is possible to measure and record in the wider range of 40 to 110 C Please take...

Страница 13: ...Modes One time Mode When the number of recorded readings reaches 8000 FULL will appear in the unit s LCD display and recording will automatically stop Endless Mode When the number of recorded reading...

Страница 14: ...TR 5 RVR 52 RTR 57C 57U TR 5 TR 7 TR 57C 57U Copyright 1995 2006 TandD Corporation All rights reserved MS Windows 2000 Xp MS Windows 98SE Me T D Recorder for Windows Software CD ROM x 1 User s Manual...

Страница 15: ...Before connecting the TR 73U to the computer with a USB cable make sure to first install the software When you connect the TR 73U to the computer before installing the software the following message...

Страница 16: ...ISPLAY Pressing this button will change the LCD Display Mode INTERVAL Pressing this button will display the currently set recording interval REC STOP Pressing this button will start or stop recording...

Страница 17: ...of recorded readings reaches 8000 the oldest data readings will be overwritten and recording will continue 5 Battery Life Warning Signal When the battery power becomes low a mark will appear on the L...

Страница 18: ...and all data will be saved for downloading 2 If the battery is not changed and power becomes even lower SLP will appear in the LCD display The unit will automatically go into sleep mode in order to pr...

Страница 19: ...ER switch the unit will turn off During recording the power cannot be turned off Please stop recording first and then turn off the power Even if the power has been turned off the recorded data will be...

Страница 20: ...15 and humidity under 30 RH there may occur changes in measurement readings This is not a malfunction NOTE If a sensor extension cable is being used with the data logger connected by USB to your comp...

Страница 21: ...t of the unit until the REC mark appears in the display When displayed recording has begun REC mark lights up NOTE By starting a new recording session all data currently saved in the unit will be eras...

Страница 22: ...the display 2 With each pressing of the INTERVAL button the recording interval time will change Press until the desired setting appears Recording Interval 1 2 5 10 15 20 30 seconds 1 2 5 10 15 20 30 6...

Страница 23: ...the unit you can change the screen display DISPLAY button 2 If the LCD display shows three channels readings alternatively it will show one channel as a fixed display by pressing the button By pressi...

Страница 24: ...4 seconds or 40 seconds if recording interval is 10 sec or more Logging Capacity 8 000 data sets One data set consists of readings for all channels in that type of unit Recording Interval Select from...

Страница 25: ...cal distributor for the serial communications protocol specifications Note Optional serial communication cable TR 07C is also required 3 Battery life varies depending upon the ambient temperature in w...

Страница 26: ...24 Optional Accessories TR 07K2 Wall Attachment Wall Attachment Included screws x 2 double sided tape x 1 US 15C USB Communication Cable Cable Length about 1 5 m...

Страница 27: ...rs can be found at http www tandd com about_tandd contactus Product Information Product information can be found at http www tandd com product Thermo Recorder TR 73U User s Manual T D CORPORATION 817...

Страница 28: ...it please contact T D directly for service 4 Free repair is not available in the following cases even though it is within the warranty period 1 Trouble or damage was caused by careless operation natur...