background image

Printed in Canada

Technical support:  1-877-715-2664

Web site:  www.townandcountryfireplaces.net

2975 Allenby Rd., Duncan, BC V9L 6V8

Содержание TC30

Страница 1: ...s are supplementary to the Installation and Operating Instructions supplied with the fireplace and should be kept together Refer to the Installation and Operating Instructions for proper gas supply sa...

Страница 2: ...2 TC30 ng01 C 140708 Notes...

Страница 3: ...lk head fitting and tighten Fig 2 Ensure that there are no leaks NOTE Primary air shutter must be fully closed for Natural gas or fully open for Propane BURNER ASSEMBLY EMBER MATERIAL 7 PCS LOG SET HA...

Страница 4: ...3 Attach the pilot supply tube to the bulk head fitting and tighten Fig 3 Ensure there are no leaks 4 Connect spark electrode wire ORANGE to the rear electrical bulk head fitting Connect the flame sen...

Страница 5: ...ers until level with the top of the pan at rear and gradually slope forward to the firebox floor at the front covering both burner tubes 3 Place remaining ember material outside of the burner pan as d...

Страница 6: ...inspect log set There should be a total of 7 logs Gas plumbing and vent con nections should be completed before proceeding Position the logs as indicated by the following pictures The three main logs...

Страница 7: ...PIN HOLE TOP LEFT LOG 3 BOTTOM RHS CHUNK 4 BOTTOM CENTER CHUNK 5 BOTTOM LHS CHUNK 6 CENTER CHUNK 7 Fig 13 Fig 15 Fig 14 Fig 16 Fig 17 Fig 18 7 TC30 ng01 C 140708...

Страница 8: ...enchremovethenaturalgas orifice 32 and replace with propane orifice 48 our part 5021 3407 Fig 22 WARNING This conversion kit shall be installed by a qualified service agency in accordance with the man...

Страница 9: ...fold and air deflector 8 Witha7 16 wrenchloosenthepilothead on the pilot assembly by a half turn Fig 25 9 Slide the pilot adjustment band over and ensure that the hole in the orifice band is showing F...

Страница 10: ...should stay down Fig 31 Replace the rubber cap 15 Fill in the date and the name of the personwhoperformedtheconversionin the white area on the conversion label Peelofftheprotectivebackingandapply the...

Страница 11: ...be required to ensure a gas tight connection Correct gas pressure requirement Supply Pressure Natural Gas Propane Min Pressure 5 0 WC 12 5 WC For purpose of input adjustment Max Pressure 13 9 WC 13 9...

Страница 12: ...w 5 Rotate the shutter to increase or decrease the amount of primary air 6 Reassemble in reverse order The air shutter on the burner tube controls the primary combustion air to the gas burner and is p...

Страница 13: ...TUBE CONNECTION 1h PILOT BRACKET 1i HEAT SHIELD 1j HEAT SHIELD INSULATION 2a BASE LOG 2b TOP LEFT LOG 2c TOP RIGHT LOG 2d CENTER CHUNK 2e BOTTOM LHS CHUNK KIT CONTENTS 2f BOTTOM CENTER CHUNK 2g BOTTOM...

Страница 14: ...14 TC30 ng01 C 140708 Notes...

Страница 15: ...15 TC30 ng01 C 140708 Notes...

Страница 16: ...Printed in Canada Technical support 1 877 715 2664 Web site www townandcountryfireplaces net 2975 Allenby Rd Duncan BC V9L 6V8...

Отзывы: