Alarm Categories and Conditions
Instruction Manual: Professional Receivers and Decoders (IRD)
Page D-7
ST.TM.TT1220.1
Table D.8: PSI/SI Related Alarm Categories and Conditions
Alarm Category
Contents
Alarm
Description
Remedy
Default
No stream
input
No stream is detected.
Check input signal
and verify source.
A
PAT not
present
No data is received on the
PAT PID.
Check input signal
and verify source.
A
CAT not
present
No data is received on the
CAT PID.
Check input signal
and verify source.
A
PMT not
present
No data is received on the
PMT PID.
Check input signal
and verify source.
A
NIT not
present
No data is received on the
NIT PID.
Check input signal
and verify source.
A
SDT/BAT not
present
No data is received on the
SDT or BAT PID.
Check input signal
and verify source.
A
CA system:
TDT not
present
No data is received on the
TDT PID.
Check input signal
and verify source.
A
D.5
Hardware Related Alarms
D.5.1
Config Alarms
The config alarms contains alarms regarding the mismatches between
present hardware, software and license keys, and the overall health of the
hardware.
Table D.9: Hardware Configuration Related Alarm Categories and Conditions
Alarm Category
Contents
Alarm
Description
Remedy
Default
Init fail
General initialisation failure.
Contact
TANDBERG
Television Customer
Help Desk
A
Cfg. Not supp
The configuration defined by
the configuration word could
not be supported.
A
Config alarms:
HW err.
The hardware check during
initialisation failed.
A
Содержание TT1220 Series
Страница 10: ...Introduction Page 1 2 Instruction Manual Professional Receivers and Decoders IRD ST TM TT1220 1 BLANK ...
Страница 18: ...Introduction Page 1 10 Instruction Manual Professional Receivers and Decoders IRD ST TM TT1220 1 BLANK ...
Страница 48: ...Alarms Page 5 2 Instruction Manual Professional Receivers and Decoders IRD ST TM TT1220 1 BLANK ...
Страница 52: ...Alarms Page 5 6 Instruction Manual Professional Receivers and Decoders IRD ST TM TT1220 1 BLANK ...