background image

 

Termination Internal Tape Drive  

The Internal SCSI-bus cable must be terminated as shown in 

Figure 4

 according to 

SCSI specifications. If the tape drive is the last device on the bus, the bus must be 
terminated within 10 cm of the tape drive connection.  

Tandberg LTO-1, LTO-2, LTO-3 have a combined SCSI-LVD/SE interface 
embedded. The PC-98 Specification specifies that the termination of the SCSI-bus 
system is a part of the SCSI-cable and not a part of the SCSI-device. As a result, 
termination cannot be turned on or off directly on the tape drive itself.  

For internal devices, a SCSI-cable with an integrated terminator or a separate 
terminator applied to the end connector of the cable, 10 cm from the last device, 
must be used.  

 

Figure 4 

Internal SCSI cable and termination 

External Tabletop Enclosure  

For front view, please see the picture on the front page. 

 

 

 

 

 

 

 

 

Figure 5 

 External tabletop enclosure, rear side 

SCSI Identification on External Tabletop  

Make sure that the drive unit has the proper SCSI-ID before it is connected to a 
computer system. Refer to manuals for host computer and application software to 
obtain the correct ID.  

External Tabletop Enclosures have a thumb-wheel switch to set the SCSI-ID for 
the tape drive (see 

Figure 5

).  

Host 

Last SCSI Device 

Internal Terminator Connector 

SCSI-bus 

10 cm 

Cooling Fan

 

SCSI_ID Switch

SCSI Interface Connectors

 

Power Connector

 

ON/OFF Switch

 

Содержание LTO HH

Страница 1: ...6 August 2007 Tandberg Tandberg Tandberg Tandberg LTO HH LTO HH LTO HH LTO HH LTO LTO LTO LTO 1 LTO 1 LTO 1 LTO 1 LTO 2 LTO 2 LTO 2 LTO 2 LTO 3 3 3 3 220LTO 420LTO 820LTO Tape Drive Quick Installatio...

Страница 2: ...hassis and at the bottom of the drive Figure 1 Mounting specifications Important Mounting screw requirements Only M3 metric screws must be used for mounting the drive Maximum permitted screw penetrati...

Страница 3: ...tape drive Figure 3 Drive connectors The factory default drive number setting is SCSI ID 2 If the drive has to be set up with a different unit number the jumpers on the Service Connector have to be c...

Страница 4: ...h an integrated terminator or a separate terminator applied to the end connector of the cable 10 cm from the last device must be used Figure 4 Internal SCSI cable and termination External Tabletop Enc...

Страница 5: ...ion Figure 6 External SCSI cabling and termination SCSI Cables Ordering no Internal SCSI LVD SE cable with 5 connectors Ordering no 43 20 51 Internal removable SCSI LVD SE terminator Ordering no 43 20...

Страница 6: ...ON ON ON Cartridge not loaded OFF OFF ON OFF OFF Cartridge loaded no activity ON OFF ON OFF OFF Cartridge loaded activity ON Flashing ON OFF OFF Cleaning OFF Flashing ON OFF Cartridge loading or unlo...

Страница 7: ...Generation 2 Native format LTO Ultrium Generation 1 Read Write compatible 609 m 609 m 200 GByte 100 GByte 43 27 44 43 26 30 LTO 3 LTO Ultrium Generation 3 Native format LTO Ultrium Generation 2 Read...

Страница 8: ...el Local 303 442 4333 Tandberg Data GmbH Feldstrasse 81 D 44141 Dortmund Germany Tel 49 231 5436 0 Fax 49 231 5436 111 Tandberg Data S A S 16 18 Ave Morane Saulnier F 78941 V lizy Cedex France Tel 33...

Отзывы: