4
Termination Internal Tape Drive
The Internal SCSI-bus cable must be terminated as shown in
Figure 4
according to
SCSI specifications. If the tape drive is the last device on the bus, the bus must be
terminated within 10 cm of the tape drive connection.
Tandberg LTO-1, LTO-2, LTO-3 have a combined SCSI-LVD/SE interface
embedded. The PC-98 Specification specifies that the termination of the SCSI-bus
system is a part of the SCSI-cable and not a part of the SCSI-device. As a result,
termination cannot be turned on or off directly on the tape drive itself.
For internal devices, a SCSI-cable with an integrated terminator or a separate
terminator applied to the end connector of the cable, 10 cm from the last device,
must be used.
Figure 4
Internal SCSI cable and termination
External Tabletop Enclosure
For front view, please see the picture on the front page.
Figure 5
External tabletop enclosure, rear side
SCSI Identification on External Tabletop
Make sure that the drive unit has the proper SCSI-ID before it is connected to a
computer system. Refer to manuals for host computer and application software to
obtain the correct ID.
External Tabletop Enclosures have a thumb-wheel switch to set the SCSI-ID for
the tape drive (see
Figure 5
).
Host
Last SCSI Device
Internal Terminator Connector
SCSI-bus
10 cm
Cooling Fan
SCSI_ID Switch
SCSI Interface Connectors
Power Connector
ON/OFF Switch