background image

Troubleshooting and technical support information

13

Troubleshooting and technical support information

Using the event log to help solve a problem

Unless you are experiencing a problem, all event logging sources should be set to the 
default, which is 

Errors, warnings and information

. For more information about 

configuring the event log, refer to the online help accessible from the web interface.
You can use the event log to produce debugging information to assist technical 
support in solving your problem. However, we recommend that you only alter the 
setting of the event log under the guidance of technical support. In particular, you 
should not turn on event logging sources without good cause or advice from 
technical support.

Getting more help

If the documentation does not answer your question or you have a problem with one 
of our products:
1

Refer to the Technical FAQ section of the web site. We keep the Technical FAQ 
section up to date with the latest information from our technical support team 
regarding the resolution of customer issues.

2

Contact your reseller. Our resellers have a wealth of experience with our 
products and this is often a quick way of solving a problem.

3

If your query remains unsolved, there is a web form in the support area of the 
web site that you can complete. Ensure that you provide all the details requested 
by the form to assist the technical support team in resolving your problem:

 

the serial number and product model number (for example: MCU4510) of 
the unit  

 

the software build number (to find this, in the web interface, go to 

Status > 

General

)

 

where you purchased the unit

 

your contact email address or telephone number

Содержание Codian HD MCU 4500 Series

Страница 1: ...Codian HD MCU MCU 4500 Series Getting started...

Страница 2: ...Codian MCU MCU 4500 Series Getting started...

Страница 3: ...an Limited provides this documentation without warranty term or condition of any kind either implied or expressed including but not limited to the implied warranties terms or conditions of merchantabi...

Страница 4: ...MCU optional 6 Step four Discover the IP address of the MCU 6 Configuring the MCU 7 Step one Log in to the MCU 7 Step two Using an H 323 gatekeeper or SIP registrar optional 7 Step three Add endpoint...

Страница 5: ...quality Package contents The following items are included with the MCU Verify that you have these items before installing the device Codian MCU device Console cable blue Power cable Rack mounting kit...

Страница 6: ...ating normally Alarm Red The MCU is booting or has developed a fault for example temperature is outside normal limits fan failure battery failure of the internal clock Refer to the web interface for m...

Страница 7: ...nk has been negotiated as a full duplex link Act Green Packets are being transmitted on this port Link Green The speed of the link from this port which is either 10 100 or 1000 Mbps Power Blue The MCU...

Страница 8: ...ble from Ethernet Port A to an Ethernet switch rather than a hub to minimize interference from other devices on the network The Ethernet port is a 10 100 1000 Mbps auto sensing connection IMPORTANT Be...

Страница 9: ...nd prompt appears on the terminal MCU Step two Configure Ethernet Port A settings The default setting for the MCU Ethernet ports is auto sensing mode If the switch ports to which you connect the MCU a...

Страница 10: ...etmask default gateway address DNS server address For example to assign an address of 192 168 1 2 where the default gateway is at 192 168 1 1 enter static 192 168 1 2 255 255 255 0 192 168 1 1 0 0 0 0...

Страница 11: ...built in gatekeeper refer to the online help If you have SIP endpoints using a SIP registrar can make it easier for participants to call in to a conference To configure the MCU to use an H 323 gatekee...

Страница 12: ...ticipants list This is easier than entering each endpoint s details every time Participants that are pre configured for a conference will automatically be called by the MCU to join that conference To...

Страница 13: ...n about the available settings 7 Scroll down and click Add conference The conference you have created is now active if you used the default immediate start time and participants can join in one of two...

Страница 14: ...the number registered with the SIP registrar for the required endpoint 4 Leave the other fields as their default values and click Call endpoint The MCU automatically connects to the endpoint 5 If the...

Страница 15: ...nfigure the streaming options you require referring to the online help for more details about options 3 Click Apply changes Streaming users will need to have installed one of the media players that yo...

Страница 16: ...ongside the software images in the support section of the web site To check for and download updates 1 Log in to the MCU web interface and go to Status General 2 Make a note of the software version th...

Страница 17: ...t Getting more help If the documentation does not answer your question or you have a problem with one of our products 1 Refer to the Technical FAQ section of the web site We keep the Technical FAQ sec...

Страница 18: ...wrist strap to an appropriate earth point Table 2 MCU ratings Rating Value Nominal voltage 115V to 230V 50 60 Hz Current rating 6A Maximum Supply voltage range 100 to 240V 50 60 Hz Caution over curren...

Страница 19: ...61 0011 05...

Отзывы: