7
Power on the
autoloader
Push the power switch on the back
of the autoloader to the on position
(the 1 is pressed).
When you first power on the
autoloader, it automatically runs a
Power On Self Test (POST). During
the POST, the left (green) LED flash-
es. After the POST, the left (green)
and right (amber) LED flash alter-
nately.
Wait while the autoloader performs
its power-on sequence. During this
time, the following activities occur:
• The LCD displays the model and
firmware.
• The LCD displays the tests being
performed as part of the internal
power-on.
Note:
If the autoloader displays a
warning message, press
Escape
to
clear the message.
• The autoloader performs a calibra-
tion and magazine element status.
The Ready LED flashes green. A +
appears in the upper right corner
of the LCD while calibration is in
progress.
When the power-on sequence com-
pletes and the autoloader is ready,
the LCD displays a list of the
autoloader options that are present
and the Ready LED is steady green.
Note:
If there is a warning message
indicating a change, you may need to
press
Escape
to clear the message.
Note:
After the first time you power
on the autoloader, you should use
the switch on the front to power on
and off the autoloader.
a
b
17
6
Connect the
power cord
Note:
The first time you power on the
autoloader, do not power on the host.
Make sure that the power switch on the
back of the autoloader is off (the 0 is
pressed).
Connect the female end of the power
cord to the power connector on the back
of the autoloader.
Plug the male end of the power cord into
the power source.
a
b
c
16
Содержание SUPERLOADER DLT -