15
OF
16
4.
Completing the installation—
a.
Attach the SCSI cover plates and the tape drive cover plate that came with your replacement kit. See
R
ESUMING
O
PERATION
1.
Power the library off (press the 0 on the back of the unit).
2.
Connect the interface cables.
Connect the Fibre Channel cable (or cables if you installed more than one Fibre Channel tape drive).
or...
Connect the SCSI cable (or cables if you installed more than one tape drive) and a terminator (if needed).
Notes:
You must install a terminator on the device at the physical end of the SCSI bus. If one of the tape drives in
the library terminates the SCSI bus, you must install the required terminator on one of the tape drive’s
SCSI connectors. If there are additional devices on the SCSI bus, ensure that only the device at the
physical end of the bus is terminated.
The library communicates with the host through the SCSI interface of one of the tape drive via the
Automation Drive Interface (ADI) serial interface.
See the tape drive’s Product Manual for tape drive information.
www.storage.ibm.com/tape/lto/oem/index.html
Hewlett Packard —
www1.hp.com/storage/tapestorage.html
See Automation/Drive Interface for ADI information:
3.
Reconnect the power cord and power on the library (press the
I
on the back of the unit).
4.
Power on the host.
If your library has...
Attach this SCSI cover plate...
Tape drive configuration
Quantity
Location
External drive label
Full height
Two
None
None
One
Top
Drive 2
a
a
This applies to both SCSI and Fibre Channel library configurations.
!
Important
The library requires both the SCSI cover plates and the tape drive cover plates for
ESD protection. Do not leave any openings uncovered.
!
Important
Both LTO-2 and LTO-3 tape drives require an Ultra 3 or LVD 160 terminator to function
properly on the SCSI bus. An inadequate terminator will result in various SCSI bus issues,
including bus hangs and Read/Write failures. See the individual Product Manuals at
for detailed information.