background image

tams 

elektronik

FD-R Basic 2

English

6.1. Connector pin assignment

Colour 
of wire

Connection to 
(for use of settings in state of delivery)

X1

white

AUX1 (lighting forward motion, function key F0)
max. current: 300 mA

X2

green

AUX2 (function key F1)
max. current: 300 mA

X3

brown

Negative pole (-) of buffer capacitor

X4 
X5

black

red

Current collector 

(right / left in direction of motion)

:

X4= left current collector (or vehicle ground)
X5= right current collector (or slider)

X6

yellow

AUX3 (lighting backward motion, function key F0)
max. current: 100 mA

X7

blue

Return conductor for all functions (+)
Positive pole (+) of buffer capacitor

Fig. 1: Connections

Page 15

Содержание FD-R Basic 2

Страница 1: ...t a m s e l e k t r o n i k Manual FD R Basic 2 Item no 42 01160 42 01161 Function decoder and RailCom transmitter tams elektronik n n n MM DCC MM DCC...

Страница 2: ...oltage supply 16 6 3 Connecting accessories to the outputs 16 6 4 Connecting LEDs to the function outputs 16 6 5 Connecting inductive loads 19 6 6 Connecting accessories via a relay 19 6 7 Connecting...

Страница 3: ...s manual mentions the following companies Gebr M RKLIN Cie GmbH Stuttgarter Str 55 57 DE 73033 G ppingen Uhlenbrock Elektronik GmbH Mercatorstrasse 6 DE 46244 Bottrop 0 201 Tams Elektronik GmbH All ri...

Страница 4: ...nother person please pass on the manual with it Intended use The function decoder FD R Basic 2 is designed to be operated according to the instructions in this manual in model building especially in d...

Страница 5: ...04 mm for all connections In order to bridge short current interruptions you need an electrolytic capacitor with a capacity of 100 to 470 F and a proof voltage of minimum 25 V 2 Safety instructions C...

Страница 6: ...this module as described in this manual and only use certified transformers Connect transformers and soldering irons only in approved mains sockets installed by an authorised electrician Observe cabl...

Страница 7: ...e and can cause accidents fires and injury Prevent this by working in a clean dry room with enough freedom of movement Other dangers Children can cause any of the accidents mentioned above because the...

Страница 8: ...the soldering tip to the soldering spot in such a way that the wire and the soldering eye are heated at the same time Simultaneously add solder not too much As soon as the solder becomes liquid take i...

Страница 9: ...multiple protocol decoder that can operate with and automatically recognise both DCC or Motorola formats The number of addresses is dependant on the format being used Motorola Format 255 addresses DC...

Страница 10: ...speed control provided the return conductor of the lamps or accessories is connected to the decoder s return conductor for all functions 4 2 Function outputs The decoder has three function outputs for...

Страница 11: ...e decoder to the digital central unit or to special receivers so called detectors The decoders must be designed to send the RailCom messages When so programmed the FD R Basic 2 sends on channel 1 cont...

Страница 12: ...n procedure for programming on main the POM update can be performed with the following central units only status 01 2015 MasterControl Tams Elektronik Intellibox 1 Uhlenbrock CS2 Maerklin The current...

Страница 13: ...ds max 20 mA Max total current 700 mA Number of function outputs max current per output 3 AUX1 and AUX2 300 mA AUX3 100 mA Connection for buffer capacitor Capacity Electric strength 1 100 to 470 F 25...

Страница 14: ...isolated connecting wires as well at the stripped ends of connecting wires not in use or insufficient fixing and isolating the decoder or the accessory for example Risk of short circuit Before connec...

Страница 15: ...X2 green AUX2 function key F1 max current 300 mA X3 brown Negative pole of buffer capacitor X4 X5 black red Current collector right left in direction of motion X4 left current collector or vehicle gr...

Страница 16: ...he outputs to the function keys voluntarily by setting the configuration variables If the lamp or the accessory is already connected with one side to vehicle ground the connection is complete If not c...

Страница 17: ...ing on the series resistor s value The maximum number of LEDs to be connected in series results from Peak value of the operating voltage sum of the forward voltages of all LEDs 0 The advantage of this...

Страница 18: ...has been reached 2 to 4 V depending on the fluorescent colour which makes this solution suitable for analogue mode Disadvantageous is the high current consumption The formula for the calculation of th...

Страница 19: ...you want to switch an accessory accessories via the decoder which connection would lead to exceeding the maximum current at the output or of the decoder you can switch the accessories via a relay e g...

Страница 20: ...you can find a remedy by connecting a buffer capacitor The electrolytic capacitor should have a capacity of 100 to 470 F and an electric strength of minimum 25 V Observe the correct polarity when con...

Страница 21: ...unless there is a sufficient current For that reason you should mount an accessory with a current consumption of minimum 100 mA to one of the outputs before starting to program the function decoder P...

Страница 22: ...erform a reset at the central unit pushing stop and go simultaneously 2 Set the current decoder address default value 3 or the address 80 3 Set all functions to off 4 Push button stop switch off the t...

Страница 23: ...Central Station I or the Mobile Station of Maerklin you can program the registers Select the article no 29750 from the locomotive database and program the decoder as described for this article in the...

Страница 24: ...he supported vehicle decoder not compatible to RailCom The values of these CVs are transmitted on a CV read out command when in CV 888 the operating mode RailCom transmitter is set in CV 28 the RailCo...

Страница 25: ...ecoder CV 888 1 CV 28 2 or 3 CV 29 RailCom on Memory area RailCom transmitter CV 888 0 CV 28 2 or 3 CV 29 RailCom on Common memory area Rails RailCom detector Central unit Page 25 Basic extended consi...

Страница 26: ...parameters the input value has to be calculated by adding the numerical values assigned to the desired parameters Memory area RailCom transmitter You can save either the values of CVs 1 to 256 of a DC...

Страница 27: ...will be programmed anew as well If you want to avoid this you can interrupt the decoder s connection to a rail collector before programming the FD R Basic 2 Setting the address Name of CVs MM register...

Страница 28: ...isters No Input value Default Remarks and Tips Version 7 Read only in DCC format Manufacturer 8 62 Read only in DCC format Auxiliary functions Name of CVs MM registers No Input value Default Remarks a...

Страница 29: ...1 29 0 64 14 Direction Standard 0 Reverse direction 1 14 speed levels 0 28 or 128 speed levels 2 Analoge recognition off 0 Analoge recognition on 4 RailCom off 0 RailCom on 8 Basic addresses 0 Not for...

Страница 30: ...AUX2 to be switched with F5 CV 39 1 Example AUX1 and AUX2 to be switched with F6 CV 40 3 1 2 Dimming of the outputs Name of CVs MM registers No Input value Default Remarks and Tips AUX3 49 1 64 64 Red...

Страница 31: ...Duration till on AUX3 58 0 255 255 0 immediate switching on at the beginning of a phase AUX1 59 0 255 255 1 254 delayed switching on AUX2 60 0 255 255 255 permanently off Duration on within a phase A...

Страница 32: ...0 0 You can download the newest firmware from our homepage without charge When getting on the part of any third parties a packed file e g zip you have to unpack it first 3 Get ready the CD with the p...

Страница 33: ...ating the other decoders As an alternative you can cut them from current shortly in order to stop them flashing quickly Performing the POM Update After having changed into the update mode you can star...

Страница 34: ...der with the default values Program the decoder anew Possible cause Instead of saving the settings into the function decoder area the settings were saved into the RailCom transmitter area of the FD R...

Страница 35: ...d instead of the RailCom transmitter area Alter the value in CV 28 to 1 Possible cause Instead of saving the settings into the RailCom transmitter area they have been saved into the function decoder a...

Страница 36: ...s the same as the one of the FD R Basic 2 the changes were taken over for the decoder as well Set the value 1 for CV 888 Then you program the RailCom transmitter area and the combined decoder not comp...

Страница 37: ...ee the maximum fee for the repair is 50 of the sales price according to our valid price list We reserve the right to reject the repairing of a decoder when the repair is impossible for technical or ec...

Страница 38: ...quality of the components as well as the function of the parts according to the parameters in not mounted state We guarantee the adherence to the technical specifications when the kit has been assembl...

Страница 39: ...tions connection diagrams and PCB layout included with this manual Use only original spare parts for repairs 2011 65 EG on the restriction of the use of certain hazardous substances in electrical and...

Страница 40: ...ormation and tips n n http www tams online de n n n Warranty and service n n Tams Elektronik GmbH n Fuhrberger Stra e 4 DE 30625 Hannover fon 49 0 511 55 60 60 fax 49 0 511 55 61 61 e mail modellbahn...